Product Overview
The Goodman GD9S800804BN is an 80,000 BTU gas furnace designed for residential ducted heating systems. Its 80% AFUE rating, single-stage burner, and multi-speed ECM blower motor support indoor heating and air circulation during colder months.
This model provides approximately 64,000 BTU of heating output and accommodates downflow and horizontal equipment configurations. It operates on a single-phase electrical supply. Homeowners comparing gas furnaces can evaluate this model based on its heating capacity, fuel efficiency, airflow settings, electrical requirements, and compatibility with existing HVAC components.
Key Features of Goodman GD9S800804BN
-
80,000 BTU Heating Input: Designed for homes with corresponding heating demands.
-
64,000 BTU Heating Output: Provides usable thermal energy for residential heating.
-
80% AFUE Rating: Indicates annual fuel utilization efficiency.
-
Single-Stage Burner: Operates at one heating level during active heating cycles.
-
Multi-Speed ECM Blower Motor: Allows airflow adjustments through selectable speed settings.
-
Downflow and Horizontal Design: Supports different residential ductwork layouts.
-
110V/120V Electrical Supply: Operates on single-phase power.
-
107-Pound Shipping Weight: Provides a useful reference for equipment handling and transportation.
Heating Performance and Capacity
The Goodman GD9S800804BN has an input capacity of 80,000 BTU per hour and an approximate output of 64,000 BTU per hour. When the indoor temperature falls below the thermostat setting, the furnace operates at its designated heating stage.
Choosing the appropriate furnace capacity involves evaluating insulation, ceiling height, local winter temperatures, windows, and building air leakage. A professional heating load calculation helps determine whether this model matches the property's requirements.
AFUE Rating and Energy Efficiency
The 80% Annual Fuel Utilization Efficiency (AFUE) rating means approximately 80% of the fuel energy consumed annually is converted into usable heat.
This measurement helps buyers compare different gas furnace models. Household fuel consumption also depends on thermostat settings, outdoor temperatures, insulation quality, and daily heating requirements.
The GD9S800804BN uses a non-condensing furnace design with single-stage heating operation.
Multi-Speed ECM Blower Motor Technology
The electronically commutated motor (ECM) moves heated air through the connected supply ductwork. Its selectable speed settings allow airflow to be matched to the requirements of compatible HVAC components.
The multi-speed blower and single-stage burner serve different purposes. While the burner produces heat at a fixed level, the blower circulates air according to the selected speed setting.
System Compatibility and Requirements
The Goodman GD9S800804BN supports downflow and horizontal equipment arrangements. Its listed shipping dimensions are 17.5 inches wide, 33⅜ inches high, and 28 inches deep, with a shipping weight of 107 pounds.
The furnace operates on a 110V/120V, single-phase, 60 Hz electrical supply. The product specification table lists a minimum circuit amperage of 12.45 amps and maximum overcurrent protection of 15 amps.
A qualified HVAC professional should confirm electrical connections, gas supply, venting, equipment clearance, and ductwork compatibility.
Ideal Applications
The Goodman GD9S800804BN gas furnace can be considered for:
-
Residential properties with matching calculated heating loads.
-
Homes with downflow central heating systems.
-
Compatible horizontal HVAC arrangements.
-
Ducted systems requiring single-stage gas heating.
-
Residential heating systems requiring selectable blower speeds.
Why Choose Goodman GD9S800804BN?
The Goodman GD9S800804BN combines an 80,000 BTU heating input with straightforward single-stage operation and adjustable airflow settings. Its 80% AFUE rating provides a clear reference for comparing fuel efficiency with other furnace models.
Buyers who require downflow or horizontal equipment can consider this model based on its heating output, blower technology, and system compatibility.
Equipment Care Tips
-
Check air filters regularly according to manufacturer recommendations.
-
Keep supply and return air vents unobstructed.
-
Maintain adequate clearance around the furnace.
-
Keep combustion air openings clear of debris.
-
Arrange periodic equipment inspections with a qualified HVAC professional.
Compare Goodman 80,000 BTU Downflow Gas Furnaces
The table below compares the GD9S800804BN with the other Goodman GD9 downflow/horizontal gas furnaces at 80,000 BTU/h input with a 4 ton blower, so you can choose the right efficiency, staging and cabinet size for your home. Specs are from Goodman engineering data.
| Model |
AFUE |
Heat stages |
Heating output (BTU/h) |
Blower supports |
Cabinet width |
Burner |
Venting |
GD9S800804BN (this model)
|
80% |
Single-stage |
64,000 |
Up to 4 tons |
17-1/2" |
Standard |
Non-condensing (metal vent) |
| GD9S800804BX |
80% |
Single-stage |
64,000 |
Up to 4 tons |
17-1/2" |
Low NOx |
Non-condensing (metal vent) |
| GD9T800804BX |
80% |
Two-stage |
64,000 / 44,800 low |
Up to 4 tons |
17-1/2" |
Low NOx |
Non-condensing (metal vent) |
| GD9S960804CN |
96% |
Single-stage |
76,880 |
Up to 4 tons |
21" |
Standard |
Condensing (PVC vent) |
Key Differences at a Glance
-
80% AFUE furnaces cost the least up front and vent through a standard metal flue, which makes them the easiest replacement for an older 80% furnace. They suit mild winters or homes where a new PVC vent is hard to run.
-
96% AFUE furnaces are condensing models that use about 17% less gas than an 80% furnace for the same heat. They pay back fastest in cold climates, and they need PVC venting and a condensate drain.
-
Single-stage models run at full fire every time they turn on. They are the simplest and lowest-cost option.
-
Two-stage models run on a lower fire most of the time and switch to full fire only on the coldest days, for more even temperatures and quieter operation.
- Model numbers ending in X are Low NOx versions and models ending in U are Ultra-low NOx versions for areas with strict emission rules, such as California air districts. Check your local code before buying.
- Every model in this table is a downflow/horizontal furnace with a multi-speed ECM blower. The blower size sets how much air conditioning the furnace can support, so match it to your AC tonnage, and check cabinet width if the furnace goes in a tight closet.
Questions Shoppers Ask About Goodman Furnaces
Is Goodman a good furnace brand?
Yes. Goodman is one of the best-selling furnace brands in the U.S. and has been owned by Daikin, the world's largest HVAC manufacturer, since 2012. The GD9S800804BN uses a durable silicon nitride igniter and a multi-speed ECM blower, and Goodman furnaces carry one of the strongest heat exchanger warranties in their price range. A correct installation and sizing matter most for long-term reliability.
What is the difference between a single-stage and a two-stage furnace?
A single-stage furnace like the GD9S800804BN has one flame setting: it runs at full output (64,000 BTU/h) every time it turns on. A two-stage furnace also has a lower setting that it uses most of the time, which gives more even temperatures and quieter operation. Single-stage furnaces cost less and are simpler, which makes them a good fit for mild climates and budget-focused replacements.
What is a downflow furnace?
A downflow furnace pulls return air in at the top and blows heated air out the bottom. The GD9S800804BN is a downflow/horizontal model, so it fits homes where the furnace sits in a closet or attic and the supply ducts run below it, such as homes on a slab or with crawl space ductwork. It can also be installed horizontally. If your current furnace sends air up into ducts above it, you need an upflow model instead.
How long does a Goodman furnace last?
A Goodman gas furnace typically lasts 15 to 20 years. Annual maintenance makes the biggest difference: change the filter regularly, keep the flame sensor clean and have a technician check the burners, heat exchanger and venting every fall.
Does the GD9S800804BN have a pilot light?
No. The GD9S800804BN has no standing pilot light. It uses a silicon nitride hot-surface igniter that lights the burners only when the thermostat calls for heat, so no gas is burned while the furnace is idle.
How do I tell how old my Goodman furnace is?
Check the serial number on the rating plate inside the furnace door. On Goodman furnaces, the first two digits of the serial number are the year and the next two are the month it was built. For example, a serial number starting with 2311 means the furnace was made in November 2023.
What warranty comes with a Goodman furnace?
When the GD9S800804BN is registered online within 60 days of installation, it gets a lifetime heat exchanger limited warranty for the original owner and a 10-year parts limited warranty. Unregistered furnaces get 20 years on the heat exchanger and 5 years on parts. Labor is not included in the manufacturer warranty.
What does the model number GD9S800804BN mean?
GD9 is the Goodman downflow/horizontal multi-speed gas furnace platform, S means single-stage heat and 80 is the efficiency class (80% AFUE). 08 is the input in thousands of BTU/h (80,000 BTU/h), 4 means the blower supports up to 4 tons of cooling, the next letter is the cabinet width code (17-1/2" wide) and the last letter is the burner type (N = standard, X = Low NOx, U = Ultra-low NOx).
Frequently Asked Questions
Q1. What is the heating capacity of the Goodman GD9S800804BN?
This furnace has an 80,000 BTU heating input and approximately 64,000 BTU of heating output.
Q2. What is the AFUE rating of the Goodman GD9S800804BN?
This model has an 80% AFUE efficiency rating.
Q3. What type of blower motor does this gas furnace use?
It features a multi-speed ECM blower motor with selectable airflow settings.
Q4. What are the electrical requirements of this Goodman gas furnace?
The furnace requires a 110V/120V, single-phase, 60 Hz electrical supply.
Q5. What airflow configurations does the Goodman GD9S800804BN support?
This furnace supports downflow and horizontal equipment configurations.
Explore Links