Quick answer: When a Daikin mini split stops and its operation lamp blinks, the unit has stored a malfunction code. On most Daikin wireless remotes, point the remote at the indoor unit and hold TIMER CANCEL for about 5 seconds until "00" shows, then press it repeatedly until you hear a long beep. The code on the display when you hear the long beep is the error. U4 (indoor/outdoor communication), A5 (freeze or high-pressure protection) and E7 (outdoor fan) are among the most common.
How to Read a Daikin Mini Split Error Code With the Remote
- Point the wireless remote at the indoor unit.
- Hold the TIMER CANCEL button for about 5 seconds. "00" flashes in the temperature display.
- Press TIMER CANCEL again, one press at a time. The display steps through possible codes.
- Listen to the indoor unit. One short beep or two short beeps mean the displayed code is not the stored one. One long beep means that code is the stored error. Write it down.
- To return to normal, hold TIMER CANCEL for 5 seconds. The display also clears itself if no button is pressed for 1 minute.
Some Daikin remotes use a different method: press TEMP up, TEMP down and MODE together to enter diagnosis mode, then change each digit until you hear a long beep. If your remote doesn't respond to TIMER CANCEL, check the operation manual for your model. A blinking operation lamp with no stored code can also be a normal protection state, so read the code before assuming a fault.
Daikin Mini Split Error Code Chart
Codes and descriptions below follow Daikin's service code list. Not every code applies to every model, so confirm with your unit's manual.
| Code | Daikin description | What you can check |
|---|---|---|
| 00 | Normal, no stored error | No action needed |
| A1 | Malfunction of indoor unit PCB | Call a technician |
| A3 | Drain level control system abnormality | Check the condensate drain for clogs or kinks; then call a technician |
| A5 | High pressure control in heating, freeze-up protection control in cooling | Clean the air filter and clear blocked airflow; call if it repeats |
| A6 | Malfunction of fan motor (indoor) | Call a technician |
| C4 | Malfunction of liquid pipe thermistor for heat exchanger | Call a technician (sensor) |
| C7 | Front panel driving motor fault | Call a technician |
| C9 | Malfunction of suction air thermistor | Call a technician (sensor) |
| E1 | Defective outdoor unit PCB | Call a technician |
| E5 | Inverter compressor motor or overheat | Turn the system off and call a technician |
| E6 | Compressor motor overcurrent or lock | Turn the system off and call a technician |
| E7 | Malfunction of outdoor unit fan motor system | Check that nothing blocks the outdoor fan; then call |
| E8 | Overcurrent of inverter compressor | Turn the system off and call a technician |
| EA | Malfunction of four-way valve or cool/heat switching | Call a technician |
| F3 | Malfunction of discharge pipe temperature | Turn the system off and call a technician |
| F6 | Abnormal high pressure or refrigerant overcharged | Check for a blocked outdoor coil; then call |
| H0 | Malfunction of sensor system of compressor | Call a technician |
| H6 | Malfunction of position detection sensor | Call a technician |
| H8 | Malfunction of compressor input (CT) system | Call a technician |
| H9 | Malfunction of outdoor air thermistor | Call a technician (sensor) |
| J3 | Malfunction of discharge pipe thermistor | Call a technician (sensor) |
| J6 | Malfunction of heat exchanger thermistor (outdoor) | Call a technician (sensor) |
| L3 | Electrical component box temperature rise | Check outdoor unit airflow; then call |
| L4 | Inverter radiation fin temperature rise | Check outdoor unit airflow; then call |
| L5 | Inverter instantaneous overcurrent (DC output) | Turn the system off and call a technician |
| P4 | Malfunction of radiation fin temperature sensor | Call a technician (sensor) |
| U0 | Shortage of refrigerant | Call a technician; this usually means a leak |
| U2 | Malfunction of power supply or instantaneous power failure | Check the breaker and incoming voltage |
| U4 | Malfunction of transmission between indoor and outdoor unit | Check the outdoor unit breaker, then power-cycle once |
| UA | Improper combination of indoor and outdoor units | Confirm the indoor and outdoor units are a Daikin-approved match |
| UH | Malfunction of system | Call a technician |
The Most Common Daikin Codes, Explained
U4: Indoor and outdoor units aren't communicating
U4 means the indoor and outdoor units have lost their signal connection. Check that the outdoor unit's breaker or disconnect is on, then turn the system off at the breaker for a few minutes and restore power once. If U4 returns, a technician should check the connecting wiring, voltage and control boards.
A5: Freeze protection or high-pressure protection
A5 shows up when the indoor coil gets too cold in cooling or too hot in heating. The most common cause is restricted airflow, so clean the filter and make sure nothing blocks the indoor unit. If it repeats with a clean filter, call a technician.
U0: Refrigerant shortage
U0 points to low refrigerant, which almost always means a leak. Topping off refrigerant without finding the leak won't fix it. A licensed technician needs to find and repair the leak.
E5, E6, E8, F3 and L5: Compressor protection
These codes protect the compressor. Don't keep resetting the system to clear them. Turn it off and have a technician check it, since repeated restarts can damage the compressor.
Before You Call a Technician
- Clean or replace the indoor unit's air filter.
- Make sure nothing blocks the indoor unit or the outdoor coil and fan.
- Check the breaker and outdoor disconnect.
- Write down the code, model numbers and when the problem started.
- Check your warranty status. Daikin's parts warranty depends on registration within 60 days of installation. See our Daikin mini split warranty guide.
FAQs
Why is my Daikin mini split blinking green?
A blinking operation lamp usually means the unit has stopped because of a malfunction and stored a code. Use the TIMER CANCEL method above to read it. Lamp colors vary by model.
How do I reset a Daikin mini split error?
For codes like U4 or U2, turn the system off at the breaker for a few minutes and restore power once. Don't keep resetting compressor-protection codes such as E5, F3 or L5.
Where can I find my Daikin remote's buttons explained?
See our Daikin mini split remote control guide. Need a new remote or controller? Shop Daikin remotes and controls.