The Goodman 5 Ton Split AC GLXS5BA6010 delivers powerful, efficient cooling in large residential and light commercial settings. Featuring a two-stage scroll compressor and eco-friendly R‑32 refrigerant, this split-system unit offers balanced performance, improved comfort, and reduced environmental impact with an impressive 15.2 SEER2 rating
Key Features
-
Two‑Stage Scroll Compressor – Offers smooth transitions between low and high cooling stages, enhancing energy efficiency and comfort control.
-
15.2 SEER2 Efficiency – Exceeds current energy standards, helping reduce utility costs in both cooling and partially with heat pumps.
-
R‑32 Refrigerant – Low global warming potential for more environmentally responsible operation.
-
Factory‑Installed Filter Drier – Protects internal components by removing moisture and debris.
-
Heavy‑Gauge Steel Cabinet – Built to stand up to outdoor elements, with a durable baked powder-coat finish.
-
Service‑Friendly Access Panels – Top and side panels simplify seasonal maintenance.
Design & Installation
-
Pre‑Charged for 15‑Foot Line Sets – Streamlines installation and reduces setup time.
-
Sweat‑Connection Service Valves with Gauge Ports – Supports easy refrigerant charging and diagnostic access.
-
Large‑Capacity Design – Ideal for cooling large living areas or smaller commercial spaces efficiently.
-
AHRI Certified & ETL Listed – Meets rigorous safety and performance standards.
Performance & Compatibility
The Goodman 15.2 SEER2 R‑32 Two‑Stage AC pairs seamlessly with matched indoor air handlers or coils to create a complete, efficient split-system. Perfect for new installations or replacing older units, this model ensures quiet operation, balanced airflow, and dependable comfort in larger spaces.
📌 Explore more Goodman models:
Goodman R32 Air Conditioners
Goodman Air Conditioners
Product Specification Table
Brand | Goodman |
Model # | GLXS5BA6010 |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | 5.0 Ton |
Coil Type | |
Total Indoor Unit(s) BTU | |
Voltage Requirements | |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | |
Indoor Unit BTUs | |
Zone/Rooms | |
AHRI No | GLXS5BA6010 |
Burner Stages | |
Cabinet Width | |
Airflow Direction | |
Furnace Efficiency / AFUE | |
Furnace BTU | |
Power Phase ( Single/Three) | |
Dimensions - (Shipping Unit Width) | 37.00 in |
Dimensions - (Shipping Unit Height) | 44.00 in |
Dimensions - (Shipping Unit Depth) | |
Weight - (Shipping Unit) | 297.000 lb |
Refrigerant Pre-Charged Line Length | 15 ft |
Power Frequency | 60 Hz |
Nom. CFM | |
Motor Speed Type | 0 |
MOCP | |
Min. Circuit Amps | 36.4 A |
Min Voltage | 0 |
Max Voltage | 0 |
Max Overcurrent Protection | 60 A |
LoNox | |
Valve Size Suction (O.D.) | 7/8 in |
Valve Size Liquid (O.D.) | 3/8 in |
Liquid Line Size | |
Energy Source | 0 |
Expansion Device | 0 |
Decibels (dBA) | 75.6 dBA |
Compressor Type | Scroll |
Compressor Stages | Two Stage |
Cased vs Uncased | |
Heating Capacity - (Nominal) | 0 |
Cooling Capacity - (Nominal) | 0 |
Airflow Rate High Cooling | |
Function Category | Split Air Conditioner |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |
Reliable indoor cooling component for large HVAC systems. The Goodman CAPTA6030D3 evaporator coil is designed for upflow or downflow installation and uses eco-friendly R‑32 refrigerant. Paired with outdoor 5 Ton condensers or heat pumps, it ensures efficient refrigerant management and optimal system performance in residential and light-commercial applications.
Key Features & Performance
-
TXV Expansion Valve – Maintains precise refrigerant flow and maximizes cooling efficiency.
-
R‑32 Refrigerant Compatibility – Supports modern, environmentally conscious HVAC systems.
-
Cased Multi-Position Design – Can be installed in upflow or downflow orientations to suit diverse duct and cabinet layouts.
-
Durable Cabinet Construction – Encased in robust, insulated housing built for reliable operation.
-
Optimized for 5 Ton Systems – Engineered to match capacity and refrigerant charge requirements of large HVAC setups.
Specifications
-
System Compatibility: 5 Ton split-system condensers or heat pumps
-
Refrigerant: R‑32
-
Expansion Device: Thermostatic Expansion Valve (TXV)
-
Installation Orientation: Upflow or Downflow
-
Casing: Fully cased, insulated steel housing
Installation & Compatibility
- Designed for straightforward connection to outdoor condensers or heat pumps in full HVAC systems
- Multi-position flexibility allows seamless integration into existing ductwork or new installations
Looking for a reliable and efficient heating solution?
Explore our full range of Goodman HVAC products designed for comfort and energy efficiency.
Product Specification Table
Brand | Goodman |
Model # | CAPTA6030D3 |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | 5.0 Ton |
Coil Type | Upflow/Downflow |
Total Indoor Unit(s) BTU | |
Voltage Requirements | |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | |
Indoor Unit BTUs | |
Zone/Rooms | |
AHRI No | CAPTA6030D3 |
Burner Stages | |
Cabinet Width | |
Airflow Direction | Upflow |
Furnace Efficiency / AFUE | |
Furnace BTU | |
Power Phase ( Single/Three) | |
Dimensions - (Shipping Unit Width) | 26.75 in |
Dimensions - (Shipping Unit Height) | 32.25 in |
Dimensions - (Shipping Unit Depth) | |
Weight - (Shipping Unit) | 70 lb |
Refrigerant Pre-Charged Line Length | 0 |
Power Frequency | 0 |
Nom. CFM | |
Motor Speed Type | 0 |
MOCP | |
Min. Circuit Amps | 0 |
Min Voltage | 0 |
Max Voltage | 0 |
Max Overcurrent Protection | 0 |
LoNox | |
Valve Size Suction (O.D.) | 0 |
Valve Size Liquid (O.D.) | 0 |
Liquid Line Size | |
Energy Source | 0 |
Expansion Device | TXV |
Decibels (dBA) | 0 |
Compressor Type | 0 |
Compressor Stages | 0 |
Cased vs Uncased | |
Heating Capacity - (Nominal) | 0 |
Cooling Capacity - (Nominal) | 0 |
Airflow Rate High Cooling | |
Function Category | |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |
Efficient and adaptable heating performance for medium to large homes. The Goodman GR9T800805CX is a two-stage gas furnace featuring a nine-speed ECM blower motor and low-NOx emissions compliance. Designed for upflow or horizontal installation, it delivers consistent comfort while maintaining quiet, efficient operation.
Key Features & Performance
-
80 kBTU Heating (Input) / 64 kBTU Output @ 80 AFUE – Reliable performance for medium-sized homes.
-
Two-Stage Gas Valve – Offers quieter, more consistent heating by operating at low output for mild weather and full output in colder conditions.
-
Nine-Speed ECM Blower – Provides enhanced airflow control and improved energy efficiency.
-
SureStart® Silicon Nitride Igniter – Durable and dependable ignition throughout the unit’s lifespan.
-
Self-Diagnostic Control Board – Simplifies troubleshooting and system maintenance.
-
Low-NOx Compliant (California) – Meets environmental standards for reduced emissions.
Cabinet & Installation Features
-
Versatile Installation – Configurable for upflow, horizontal left, or right airflow.
-
Heavy-Gauge Insulated Steel Cabinet – Reduces leakage and ensures quiet operation.
-
Flexible Service Access – Includes sweat connections, low-voltage terminals, and multi-position returns.
Specifications
-
Input/Output: 80 kBTU / 64 kBTU
-
AFUE: 80%
-
Motor: Nine-speed ECM blower
-
Igniter: Silicon Nitride
-
Electrical: 115 V, 1 Phase, MCA 14.3 A, MOP 25 A
-
Dimensions: 21″ W × 28″ D × 33⅜″ H
-
Weight: ~129 lb
-
Airflow: Up to ~2,000 CFM
Warranty & Certifications
-
Heat Exchanger: Lifetime limited with registration
-
Unit Replacement & Parts: 10-year limited with registration
-
Certifications: AHRI-certified, ETL-listed, California Low-NOx compliant
Compatible Applications
- Ideal for homes requiring 80 kBTU input capacity with high airflow flexibility
- Upflow or horizontal orientation supports diverse installation layouts
- Compatible with natural gas or convertible to propane
Looking for a reliable and efficient heating solution?
Explore our full range of Goodman HVAC products designed for comfort and energy efficiency.
Product Specification Table
Brand | Goodman |
Model # | GR9T800805CX |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | |
Coil Type | |
Total Indoor Unit(s) BTU | 80000 |
Voltage Requirements | 110V To 120 V |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | Wall Mount |
Indoor Unit BTUs | 80K |
Zone/Rooms | |
AHRI No | GR9T800805CX |
Burner Stages | Two Stage |
Cabinet Width | 21" |
Airflow Direction | Upflow |
Furnace Efficiency / AFUE | 80% |
Furnace BTU | 80,000 BTU's |
Power Phase ( Single/Three) | 1 Ph |
Dimensions - (Shipping Unit Width) | #N/A |
Dimensions - (Shipping Unit Height) | #N/A |
Dimensions - (Shipping Unit Depth) | |
Weight - (Shipping Unit) | |
Refrigerant Pre-Charged Line Length | |
Power Frequency | 60 Hz |
Nom. CFM | |
Motor Speed Type | #N/A |
MOCP | |
Min. Circuit Amps | #N/A |
Min Voltage | |
Max Voltage | |
Max Overcurrent Protection | #N/A |
LoNox | |
Valve Size Suction (O.D.) | |
Valve Size Liquid (O.D.) | |
Liquid Line Size | |
Energy Source | |
Expansion Device | |
Decibels (dBA) | |
Compressor Type | |
Compressor Stages | |
Cased vs Uncased | |
Heating Capacity - (Nominal) | |
Cooling Capacity - (Nominal) | |
Airflow Rate High Cooling | |
Function Category | Gas Furnace |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |