The Goodman CAPFA6030D3 is a heavy-duty 5 Ton evaporator coil designed for upflow/downflow residential HVAC applications. Engineered to work with R-32 refrigerant, it features a factory-installed TXV (Thermal Expansion Valve) for precise refrigerant control and maximum system performance. The 24.5-inch cabinet width supports large-system configurations, making it ideal for high-capacity installations.
Key Features and Benefits:
-
5 Ton Cooling Capacity
Delivers strong and consistent cooling for large residential or light commercial systems.
-
Factory-Installed TXV
Optimizes refrigerant flow for improved energy efficiency and comfort.
-
All-Aluminum Coil
Offers superior corrosion resistance and long-term durability.
-
Upflow/Downflow Installation Design
Provides flexibility for a variety of HVAC layouts and retrofit applications.
-
24.5-Inch Cabinet Width
Accommodates wider furnace or air handler setups with ease.
-
Energy-Efficient Operation
Designed for R-32 refrigerant, reducing environmental impact and maximizing system efficiency.
This unit is part of the trusted Goodman HVAC Products line, delivering reliable comfort, performance, and energy savings.
Product Specification Table
Brand | Goodman |
Model # | CAPFA6030D3 |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | |
Coil Type | Cased |
Total Indoor Unit(s) BTU | |
Voltage Requirements | 208V To 230V |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | |
Indoor Unit BTUs | |
Zone/Rooms | |
AHRI No | |
Burner Stages | |
Cabinet Width | |
Airflow Direction | |
Furnace Efficiency / AFUE | |
Furnace BTU | |
Power Phase ( Single/Three) | 1 Ph |
Dimensions - (Shipping Unit Width) | 26.00 in |
Dimensions - (Shipping Unit Height) | 32.25 in |
Dimensions - (Shipping Unit Depth) | 26.75 in |
Weight - (Shipping Unit) | 69.090 lb |
Refrigerant Pre-Charged Line Length | |
Power Frequency | 60 Hz |
Nom. CFM | |
Motor Speed Type | |
MOCP | |
Min. Circuit Amps | |
Min Voltage | |
Max Voltage | |
Max Overcurrent Protection | |
LoNox | |
Valve Size Suction (O.D.) | 0 |
Valve Size Liquid (O.D.) | |
Liquid Line Size | |
Energy Source | Electric |
Expansion Device | Orifice |
Decibels (dBA) | |
Compressor Type | |
Compressor Stages | |
Cased vs Uncased | Cased |
Heating Capacity - (Nominal) | |
Cooling Capacity - (Nominal) | |
Airflow Rate High Cooling | |
Function Category | |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |
The Goodman GLXS3BN3610 is a reliable and energy-efficient 3-ton split-system air conditioner, ideal for cooling larger homes around 1,500–1,800 sq. ft. With a 13.4 SEER2 rating and eco-friendly R-32 refrigerant, this unit provides dependable performance, reduced environmental impact, and quiet operation.
Key Features & Performance
-
13.4 SEER2 Efficiency & R-32 Refrigerant – Meets current energy standards and utilizes an environmentally responsible refrigerant.
-
Single-Stage Scroll Compressor – Ensures steady, efficient cooling for everyday comfort.
-
Copper Tube & Enhanced Aluminum Fin Coil – Boosts heat transfer and durability.
-
Factory-Installed Filter Drier – Protects internal components from moisture and debris.
-
Quiet Operation (~69 dB) – Designed with sound-reducing technology for quieter performance.
-
Durable Galvanized Cabinet – Built with heavy-gauge steel and powder-coated finish for long-term protection.
-
Service-Friendly Design – Features top and side access, sweat-type service valves, enclosed contactor, and pressure switches for easy maintenance.
-
Certified & Warrantied – AHRI and ETL certified, with a 10-year parts warranty upon registration.
-
Hurricane-Ready Build – Meets wind-load requirements when properly anchored, making it suitable for coastal and high-wind zones.
Specifications
-
Cooling Capacity: 36,000 BTU/h (3 Ton)
-
SEER2 Rating: 13.4 (up to 13.7 depending on matched components)
-
Noise Level: Approx. 69 dB(A)
-
Refrigerant: R-32, pre-charged for 15 ft line set
-
Dimensions: 26″ W × 26″ D × 32.5″ H
-
Weight: Approx. 136–151 lbs
-
Electrical: 208/230 V, single-phase; recommended breaker size: 25–30 A
-
Piping Sizes: Liquid Line – 3/8", Suction Line – 7/8"
Installation & Compatibility
The GLXS3BN3610 is designed to pair with compatible indoor coils or air handlers to create a full split-system AC setup. It comes pre-charged for faster installation and features accessible service ports for contractor convenience. This unit is approved for use in the Northern Region of the U.S. and meets updated DOE guidelines. It is not approved for installation in Southern regions due to specific efficiency requirements.
Keywords Included
- Goodman 3 Ton Air Conditioner
- GLXS3BN3610
- Goodman 13.4 SEER2 R‑32 Cooling Unit
Summary
The Goodman GLXS3BN3610 delivers consistent, high-capacity cooling with a 13.4 SEER2 rating and R-32 refrigerant. Built for energy savings, environmental compliance, and quiet operation, it's a durable and efficient solution for large residential spaces in Northern regions. Its design, certifications, and 10-year warranty make it a strong long-term investment.
Looking for more reliable solutions?
Explore our full range of Goodman HVAC products designed for energy efficiency and long-lasting performance.
Product Specification Table
Brand | Goodman |
Model # | GLXS3BN3610 |
SEER2/EER2 | 13.4 |
Refrigerant | R-32 |
Tonnage | 3.0 Ton |
Coil Type | |
Total Indoor Unit(s) BTU | |
Voltage Requirements | 208V To 230V |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | |
Indoor Unit BTUs | |
Zone/Rooms | |
AHRI No | |
Burner Stages | |
Cabinet Width | |
Airflow Direction | |
Furnace Efficiency / AFUE | |
Furnace BTU | |
Power Phase ( Single/Three) | 1 Ph |
Dimensions - (Shipping Unit Width) | 27.50 in |
Dimensions - (Shipping Unit Height) | 34.50 in |
Dimensions - (Shipping Unit Depth) | 27.50 in |
Weight - (Shipping Unit) | 151.000 lb |
Refrigerant Pre-Charged Line Length | 15 ft |
Power Frequency | 60 Hz |
Nom. CFM | |
Motor Speed Type | |
MOCP | |
Min. Circuit Amps | 17.5 A |
Min Voltage | |
Max Voltage | |
Max Overcurrent Protection | 30 A |
LoNox | |
Valve Size Suction (O.D.) | 7/8 in |
Valve Size Liquid (O.D.) | |
Liquid Line Size | |
Energy Source | Electric |
Expansion Device | |
Decibels (dBA) | 69 dBA |
Compressor Type | Scroll |
Compressor Stages | Single Stage |
Cased vs Uncased | |
Heating Capacity - (Nominal) | |
Cooling Capacity - (Nominal) | 34200 Btu/H |
Airflow Rate High Cooling | |
Function Category | Split Air Conditioner |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |