Built for properties with substantial heating needs, this high-efficiency furnace combines two-stage heat with a variable-speed blower. Its wide airflow range also supports larger cooling systems.
The Goodman GRVT961205DN gas furnace provides up to 120,000 BTU of heating input and approximately 115,320 BTU of high-stage output.
The Goodman 120000 BTU gas furnace uses a 24.5-inch D-width cabinet and supports upflow or horizontal positioning.
With a 96.1% efficiency rating, the Goodman 96 AFUE furnace converts most of the fuel it consumes into usable indoor heat.
Goodman GRVT961205DN Overview
The Goodman GRVT961205DN gas furnace operates at two heating levels. Its lower stage uses 84,000 BTU of input and produces approximately 80,724 BTU of output. Full capacity is available when the heating demand rises.
A Goodman variable-speed ECM furnace can adjust blower output in smaller steps than a fixed-speed unit. This produces a gentler stream of conditioned air and supports steadier temperatures from room to room.
The Goodman two-stage gas furnace normally starts at its lower heating level. Longer low-stage cycles can reduce abrupt temperature changes while keeping full heating output ready for colder conditions.
The Goodman 120000 BTU gas furnace can support cooling airflow for systems ranging from approximately 2 to 5 tons. Maximum selectable cooling airflow reaches about 2,200 CFM.
Key Features of Goodman 120K BTU Gas Furnace
The Goodman GRVT961205DN gas furnace pairs substantial heating capacity with ComfortBridge controls. The system manages communication and airflow from the furnace control board, so it can work with a compatible conventional thermostat.
-
Two-stage gas valve
-
Variable-speed ECM circulator motor
-
120,000 BTU high-stage input
-
84,000 BTU low-stage input
-
96.1% AFUE efficiency rating
-
Upflow and horizontal positioning
-
Integrated ComfortBridge technology
-
Bluetooth-enabled CoolCloud diagnostics
-
Multiple continuous-fan settings
-
Auto-Comfort airflow mode
-
Enhanced dehumidification mode
-
R-32 refrigerant detection controls
-
R-410A backward compatibility
-
Aluminized-steel tubular primary heat exchanger
-
Stainless-steel secondary heat exchanger
-
Silicon nitride hot-surface igniter
-
Two-speed induced-draft blower
-
Self-diagnostic control board
-
California Low NOx compliance
-
Natural gas operation with propane-conversion capability
The condensing design helps the Goodman 96 AFUE furnace recover heat that lower-efficiency furnaces would send through the exhaust. The unit uses 2- or 3-inch approved vent piping and produces condensate during operation.
The Goodman variable-speed ECM furnace provides high-stage cooling airflow from 800 to 2,000 CFM, depending on the selected tonnage. Low-stage airflow ranges from 560 to 1,400 CFM.
Technical Specifications
|
Specification
|
Product Details
|
|
Brand
|
Goodman
|
|
Model Number
|
GRVT961205DN
|
|
Equipment Type
|
High-efficiency condensing gas furnace
|
|
Fuel Type
|
Natural gas
|
|
Propane Convertible
|
Yes, with the appropriate conversion kit
|
|
AFUE Rating
|
96.1%
|
|
Maximum Heating Input
|
120,000 BTU
|
|
Maximum Heating Output
|
Approximately 115,320 BTU
|
|
Low-Stage Heating Input
|
84,000 BTU
|
|
Low-Stage Heating Output
|
Approximately 80,724 BTU
|
|
Heating Stages
|
Two
|
|
Blower Motor
|
Variable-speed ECM
|
|
Motor Rating
|
1 HP
|
|
Nominal Cooling Airflow
|
Up to 2,000 CFM
|
|
Maximum Cooling Airflow
|
Approximately 2,200 CFM
|
|
Supported Cooling Capacity
|
Approximately 2 to 5 tons
|
|
Recommended High-Heat Airflow
|
Approximately 2,150 CFM
|
|
Temperature-Rise Range
|
35°F to 65°F
|
|
Airflow Position
|
Upflow or horizontal
|
|
Comfort Controls
|
Integrated ComfortBridge technology
|
|
Refrigerant Controls
|
R-32 refrigerant detection system included
|
|
Additional Compatibility
|
R-410A compatible when correctly configured
|
|
Primary Heat Exchanger
|
Aluminized-steel tubular design
|
|
Secondary Heat Exchanger
|
Stainless steel
|
|
Ignition Type
|
Silicon nitride hot-surface ignition
|
|
Vent Diameter
|
2 or 3 inches
|
|
Number of Burners
|
Six
|
|
Emissions Rating
|
California Low NOx
|
|
Electrical Supply
|
115V, single phase, 60 Hz
|
|
Minimum Circuit Ampacity
|
13.9 amps
|
|
Maximum Breaker Size
|
20 amps
|
|
Cabinet Size
|
D cabinet
|
|
Height
|
34.5 inches
|
|
Width
|
24.5 inches
|
|
Depth
|
28.875 inches
|
|
Weight
|
156 lbs
|
The dimensions, heating figures and equipment features were checked against the current specification data for this exact model.
GRVT961205DN Dimensions & Capacity
The Goodman GRVT961205DN gas furnace measures 34.5 inches high, 24.5 inches wide and 28.875 inches deep. Its listed weight is approximately 156 pounds.
-
Height: 34.5 inches
-
Width: 24.5 inches
-
Depth: 28.875 inches
-
Weight: 156 lbs
-
Cabinet designation: D cabinet
-
Maximum input: 120,000 BTU
-
Maximum output: approximately 115,320 BTU
-
Low-stage input: 84,000 BTU
-
Low-stage output: approximately 80,724 BTU
-
Cooling capacity range: approximately 2 to 5 tons
-
Nominal maximum cooling airflow: 2,000 CFM
The wide D cabinet gives the Goodman two-stage gas furnace enough airflow capacity for larger ducted systems while supporting upflow, horizontal-left or horizontal-right positioning.
Who Should Buy Goodman 120K BTU Gas Furnace?
The Goodman GRVT961205DN gas furnace may suit larger homes or light commercial spaces with a calculated heating load that requires up to 120,000 BTU of input.
The Goodman 120000 BTU gas furnace is also a possible match for systems that need airflow support for cooling equipment up to 5 tons. Correct sizing should be based on the property’s heating load rather than square footage alone.
A Goodman 96 AFUE furnace is suited to buyers who want high fuel utilization, staged heating and a condensing furnace design.
Buyers planning to buy Goodman GRVT961205DN online should confirm the 24.5-inch cabinet width, heating-load requirement, duct capacity and venting arrangement before ordering.
Frequently Asked Questions
Q1. What is the heating output of this furnace?
The Goodman GRVT961205DN gas furnace produces approximately 115,320 BTU at high fire and 80,724 BTU at low fire.
Q2. What does the variable-speed blower control?
The Goodman variable-speed ECM furnace adjusts airflow according to heating or cooling demand, helping the system provide smoother air circulation.
Q3. How does two-stage heating work?
The Goodman two-stage gas furnace can operate at 84,000 BTU input during moderate demand and move to its full 120,000 BTU input when additional heat is needed.
Q4. Which airflow positions does this model support?
This furnace supports upflow, horizontal-left and horizontal-right positioning. It is not a dedicated downflow model.
Q5. Can this furnace work with R-32 equipment?
Yes. Its control board includes factory-integrated refrigerant detection controls for compatible R-32 systems.