This furnace pairs moderate heating capacity with higher airflow for residential systems that require up to 1,600 CFM. Its two-stage burner and variable-speed blower can adjust operation as indoor conditions change.
The Goodman GRVT800604BN gas furnace provides 60,000 BTU of high-stage input and approximately 48,000 BTU of heating output.
The Goodman 60000 BTU gas furnace has a compact 17.5-inch cabinet with upflow and horizontal positioning.
The Goodman 80 AFUE furnace is a non-condensing model that uses an approved metal-flue venting arrangement.
The Goodman 1600 CFM furnace can support cooling systems ranging from approximately 1.5 to 4 tons, depending on the complete equipment match.
Goodman GRVT800604BN Overview
The Goodman GRVT800604BN gas furnace operates at two heating levels. Its low stage uses 42,000 BTU of input and produces approximately 33,600 BTU of output. Full capacity becomes available when the thermostat calls for more heat.
A Goodman variable-speed ECM furnace adjusts blower output gradually rather than shifting between one fixed speed and off. This helps reduce sudden airflow changes.
The Goodman two-stage gas furnace can spend longer periods at its lower firing rate during moderate conditions, then move to the 60,000 BTU stage when heating demand increases.
The increased blower capacity sets this Goodman 60000 BTU gas furnace apart from lower-airflow configurations with the same heating input.
Key Features of Goodman 60K BTU 1600 CFM Furnace
The Goodman GRVT800604BN gas furnace combines higher airflow capacity with ComfortBridge controls in a 17.5-inch-wide cabinet.
-
Two-stage gas valve
-
Variable-speed ECM circulator motor
-
60,000 BTU high-stage input
-
42,000 BTU low-stage input
-
80% AFUE efficiency rating
-
Maximum airflow of approximately 1,600 CFM
-
Upflow and horizontal positioning
-
Integrated ComfortBridge technology
-
Bluetooth-enabled CoolCloud diagnostics
-
Multiple continuous-fan settings
-
Auto-Comfort airflow mode
-
Enhanced dehumidification mode
-
R-32 refrigerant detection controls
-
R-410A backward compatibility
-
Aluminized-steel tubular heat exchanger
-
Silicon nitride hot-surface igniter
-
Two-speed induced-draft blower
-
Self-diagnostic control board
-
Natural gas operation with propane-conversion capability
-
Insulated heavy-gauge steel cabinet
The Goodman 80 AFUE furnace converts approximately 80% of its fuel into usable indoor heat. Its non-condensing design requires a 4-inch metal flue connection.
The Goodman 1600 CFM furnace is useful when the connected cooling equipment requires more airflow than a standard 1,200 CFM blower can provide.
The Goodman variable-speed ECM furnace can also maintain lower continuous-fan airflow between active heating or cooling cycles.
Technical Specifications
|
Specification
|
Product Details
|
|
Brand
|
Goodman
|
|
Model Number
|
GRVT800604BN
|
|
Equipment Type
|
Non-condensing gas furnace
|
|
Fuel Type
|
Natural gas
|
|
Propane Convertible
|
Yes, with the appropriate conversion kit
|
|
AFUE Rating
|
80%
|
|
Maximum Heating Input
|
60,000 BTU
|
|
Maximum Heating Output
|
Approximately 48,000 BTU
|
|
Low-Stage Heating Input
|
42,000 BTU
|
|
Low-Stage Heating Output
|
Approximately 33,600 BTU
|
|
Heating Stages
|
Two
|
|
Blower Motor
|
Variable-speed ECM
|
|
Motor Rating
|
3/4 HP
|
|
Maximum Airflow
|
Approximately 1,600 CFM
|
|
Supported Cooling Capacity
|
Approximately 1.5 to 4 tons
|
|
Airflow Position
|
Upflow or horizontal
|
|
Comfort Controls
|
Integrated ComfortBridge technology
|
|
Refrigerant Controls
|
R-32 refrigerant detection system included
|
|
Additional Compatibility
|
R-410A compatible when correctly configured
|
|
Heat Exchanger
|
Aluminized-steel tubular design
|
|
Ignition Type
|
Silicon nitride hot-surface ignition
|
|
Vent Connection
|
4 inches
|
|
NOx Classification
|
Standard NOx
|
|
Low NOx Compliant
|
No
|
|
Electrical Supply
|
115V, single phase, 60 Hz
|
|
Minimum Circuit Ampacity
|
10.8 amps
|
|
Maximum Breaker Size
|
15 amps
|
|
Cabinet Size
|
B cabinet
|
|
Height
|
33.375 inches
|
|
Width
|
17.5 inches
|
|
Depth
|
28 inches
|
|
Weight
|
107 lbs
|
The heating capacity, 1,600 CFM airflow rating, dimensions and weight were checked against current listings for this exact model.
GRVT800604BN Dimensions & Capacity
The Goodman GRVT800604BN gas furnace measures 33.375 inches high, 17.5 inches wide and 28 inches deep. Its listed weight is approximately 107 pounds.
-
Height: 33.375 inches
-
Width: 17.5 inches
-
Depth: 28 inches
-
Weight: 107 lbs
-
Cabinet designation: B cabinet
-
Maximum input: 60,000 BTU
-
Maximum output: approximately 48,000 BTU
-
Low-stage input: 42,000 BTU
-
Low-stage output: approximately 33,600 BTU
-
Maximum airflow: approximately 1,600 CFM
-
Cooling capacity range: approximately 1.5 to 4 tons
The compact cabinet allows the Goodman two-stage gas furnace to support upflow, horizontal-left or horizontal-right positioning without requiring a wider cabinet.
Who Should Buy Goodman 60K BTU 1600 CFM Furnace?
The Goodman GRVT800604BN gas furnace may suit smaller or medium-sized homes that need 60,000 BTU of heating input along with higher cooling airflow.
The Goodman 60000 BTU gas furnace is worth considering when the heating requirement is moderate but the connected cooling equipment needs up to 1,600 CFM.
A Goodman 80 AFUE furnace makes sense for properties designed around conventional metal-flue venting and a non-condensing heating system.
The Goodman 1600 CFM furnace may support cooling systems up to approximately 4 tons, but the furnace, indoor coil and outdoor unit must be properly matched.
Buyers planning to buy Goodman GRVT800604BN online should confirm the heating load, airflow requirement, cabinet dimensions and local NOx rules before ordering.
Frequently Asked Questions
Q1. What is the heating output of this furnace?
The Goodman GRVT800604BN gas furnace produces approximately 48,000 BTU at high fire and 33,600 BTU at low fire.
Q2. What does the variable-speed blower do?
The Goodman variable-speed ECM furnace changes airflow according to heating, cooling or continuous-fan demand.
Q3. How does two-stage heating work?
The Goodman two-stage gas furnace can operate at 42,000 BTU input during moderate conditions and move to 60,000 BTU input when more heat is required.
Q4. Is this a Low NOx furnace?
No. This is a standard-NOx model and is not classified as Low NOx or Ultra-Low NOx equipment.
Q5. Which airflow positions does this furnace support?
It supports upflow, horizontal-left and horizontal-right positioning.