This furnace is designed for residential systems that need moderate heating capacity and flexible airflow control. Its two-stage burner can reduce output during milder weather, while the ECM blower adjusts airflow more smoothly than a fixed-speed motor.
The Goodman GRVT800603BN gas furnace provides 60,000 BTU of high-stage input and approximately 48,000 BTU of heating output.
The Goodman 60000 BTU gas furnace uses a compact 17.5-inch cabinet that supports upflow, horizontal-left and horizontal-right positioning.
With an 80% efficiency rating, the Goodman 80 AFUE furnace is designed for conventional metal-flue venting.
Goodman GRVT800603BN Overview
The Goodman GRVT800603BN gas furnace operates at two heating levels. Its lower stage uses 42,000 BTU of input and delivers approximately 33,600 BTU of output. Full capacity is available when indoor heating demand rises.
A Goodman variable-speed ECM furnace can gradually adjust its blower output instead of moving air at one fixed rate. This helps provide more controlled airflow during heating, cooling and continuous-fan operation.
The Goodman two-stage gas furnace normally starts at its lower firing rate. It can move to the full 60,000 BTU input stage during colder conditions or when the thermostat calls for more heat.
The Goodman 60000 BTU gas furnace provides up to 1,200 CFM and supports cooling equipment from approximately 1.5 to 3 tons.
Key Features of Goodman 60K BTU Gas Furnace
The Goodman GRVT800603BN gas furnace combines staged heating with ComfortBridge technology and an R-32-ready control board. Its compact cabinet works well where equipment space is limited.
-
Two-stage gas valve
-
Variable-speed ECM circulator motor
-
60,000 BTU high-stage input
-
42,000 BTU low-stage input
-
80% AFUE efficiency rating
-
Maximum airflow of approximately 1,200 CFM
-
Upflow and horizontal positioning
-
Integrated ComfortBridge technology
-
Bluetooth-enabled CoolCloud diagnostics
-
Multiple continuous-fan settings
-
R-32 refrigerant detection controls
-
R-410A backward compatibility
-
Aluminized-steel tubular heat exchanger
-
Silicon nitride hot-surface igniter
-
Two-speed induced-draft blower
-
Self-diagnostic control board
-
Fully insulated steel cabinet
-
Natural gas operation with propane-conversion capability
The Goodman 80 AFUE furnace uses a 4-inch metal flue connection. Unlike a condensing furnace, it does not produce the same level of combustion condensate during normal operation.
The Goodman variable-speed ECM furnace can change airflow according to heating or cooling demand. And its 1,200 CFM capacity makes it suitable for several common residential system combinations.
Technical Specifications
|
Specification
|
Product Details
|
|
Brand
|
Goodman
|
|
Model Number
|
GRVT800603BN
|
|
Equipment Type
|
Non-condensing gas furnace
|
|
Fuel Type
|
Natural gas
|
|
Propane Convertible
|
Yes, with the appropriate conversion kit
|
|
AFUE Rating
|
80%
|
|
Maximum Heating Input
|
60,000 BTU
|
|
Maximum Heating Output
|
Approximately 48,000 BTU
|
|
Low-Stage Heating Input
|
42,000 BTU
|
|
Low-Stage Heating Output
|
Approximately 33,600 BTU
|
|
Heating Stages
|
Two
|
|
Blower Motor
|
Variable-speed ECM
|
|
Motor Rating
|
1/2 HP
|
|
Maximum Airflow
|
Approximately 1,200 CFM
|
|
Supported Cooling Capacity
|
Approximately 1.5 to 3 tons
|
|
Temperature-Rise Range
|
15°F to 45°F
|
|
Airflow Position
|
Upflow or horizontal
|
|
Comfort Controls
|
Integrated ComfortBridge technology
|
|
Refrigerant Controls
|
R-32 refrigerant detection system included
|
|
Additional Compatibility
|
R-410A compatible when correctly configured
|
|
Heat Exchanger
|
Aluminized-steel tubular design
|
|
Ignition Type
|
Silicon nitride hot-surface ignition
|
|
Vent Connection
|
4 inches
|
|
Number of Burners
|
Three
|
|
NOx Classification
|
Standard NOx; not Low NOx or Ultra-Low NOx
|
|
Electrical Supply
|
115V, single phase, 60 Hz
|
|
Minimum Circuit Ampacity
|
7.6 amps
|
|
Maximum Breaker Size
|
15 amps
|
|
Cabinet Size
|
B cabinet
|
|
Height
|
33.375 inches
|
|
Width
|
17.5 inches
|
|
Depth
|
28 inches
|
|
Weight
|
105 lbs
|
The capacity, airflow and physical specifications were checked against current data for this exact furnace model.
GRVT800603BN Dimensions & Capacity
The Goodman GRVT800603BN gas furnace measures 33.375 inches high, 17.5 inches wide and 28 inches deep. Its listed weight is approximately 105 pounds.
-
Height: 33.375 inches
-
Width: 17.5 inches
-
Depth: 28 inches
-
Weight: 105 lbs
-
Cabinet designation: B cabinet
-
Maximum input: 60,000 BTU
-
Maximum output: approximately 48,000 BTU
-
Low-stage input: 42,000 BTU
-
Low-stage output: approximately 33,600 BTU
-
Maximum airflow: approximately 1,200 CFM
-
Cooling capacity range: approximately 1.5 to 3 tons
The compact B-width cabinet allows the Goodman two-stage gas furnace to fit compatible residential equipment layouts while supporting side- or bottom-return airflow.
Who Should Buy Goodman 60K BTU Gas Furnace?
The Goodman GRVT800603BN gas furnace may suit smaller or medium-sized homes where the calculated heating requirement calls for up to 60,000 BTU of input.
The Goodman 60000 BTU gas furnace can also match systems that require airflow for approximately 1.5- to 3-ton cooling equipment. Home size alone should not be used to choose furnace capacity.
A Goodman 80 AFUE furnace makes sense for properties designed around conventional metal-flue venting and an 80% non-condensing heating system.
Buyers planning to buy Goodman GRVT800603BN online should confirm the required heating capacity, 17.5-inch cabinet width, airflow demand and NOx regulations in their area before ordering.
Frequently Asked Questions
Q1. What is the heating output of this furnace?
The Goodman GRVT800603BN gas furnace produces approximately 48,000 BTU at high fire and 33,600 BTU at low fire.
Q2. What does the variable-speed blower do?
The Goodman variable-speed ECM furnace adjusts its airflow according to heating, cooling or continuous-fan demand rather than operating at one fixed speed.
Q3. How does two-stage heating work?
The Goodman two-stage gas furnace can use its 42,000 BTU input stage during moderate demand and move to the full 60,000 BTU stage when more heat is required.
Q4. Which airflow positions does this furnace support?
This model supports upflow, horizontal-left and horizontal-right positioning.
Q5. Is this furnace classified as Low NOx?
No. This model is standard-NOx equipment and is not classified as Low NOx or Ultra-Low NOx.