The Goodman GLXS4BA4810 is a 4 ton cooling-only condenser built for residential split-system air conditioning. With 48,000 BTU of nominal cooling capacity, R32 refrigerant, and up to 14.4 SEER2 efficiency, this model is a practical option for larger homes that need steady central cooling. Its single-stage scroll compressor keeps operation simple, while the outdoor cabinet is designed to handle everyday exposure and routine HVAC use.
Goodman GLXS4BA4810 Overview
The Goodman GLXS4BA4810 is the outdoor condenser portion of a central air conditioning system. It works with compatible indoor equipment to remove heat from the home and maintain comfortable temperatures during warmer months.
As a Goodman 4 ton air conditioner, this model provides approximately 48,000 BTU of nominal cooling capacity. It uses R32 refrigerant and a single-stage scroll compressor, giving homeowners a straightforward cooling setup without the added complexity of multi-stage or variable-capacity operation.
The unit is listed with up to 14.4 SEER2 efficiency when paired with compatible indoor equipment. Final system performance can vary based on the matched coil or air handler, airflow, ductwork, and complete system configuration.
Key Features of Goodman 4 Ton R32 Condenser
The GLXS4BA4810 combines higher cooling capacity with a simple, service-friendly design.
-
4 Ton Cooling Capacity: Provides approximately 48,000 BTU of nominal cooling.
-
Up to 14.4 SEER2: Designed for efficient seasonal cooling when properly matched.
-
R32 Refrigerant: Uses current-generation refrigerant for modern residential HVAC applications.
-
Single-Stage Scroll Compressor: Delivers consistent cooling through straightforward on/off operation.
-
Durable Cabinet: Architectural gray powder-coated exterior helps protect internal components.
-
Steel Louver Coil Guard: Adds protection around the condenser coil.
-
Service-Friendly Access: Top and side maintenance access make major components easier to reach.
-
208/230V Operation: Designed for common residential split-system electrical configurations.
-
15-Foot Factory Charge: Comes factory charged for approximately 15 feet of refrigerant line.
-
73 dBA Sound Level: Listed outdoor operating sound rating.
For buyers looking for a Goodman R32 condenser in the 4 ton range, this model offers the capacity needed for larger residential cooling loads without moving into more complex equipment.
Technical Specifications
|
Specification
|
Details
|
|
Brand
|
Goodman
|
|
Model Number
|
GLXS4BA4810
|
|
Product Type
|
Cooling-Only Split-System Condenser
|
|
Nominal Capacity
|
4 Ton
|
|
Cooling Capacity
|
48,000 BTU nominal
|
|
Efficiency
|
Up to 14.4 SEER2
|
|
Refrigerant
|
R32
|
|
Compressor Type
|
Scroll
|
|
Compressor Stages
|
Single Stage
|
|
Voltage
|
208/230V
|
|
Phase
|
Single Phase
|
|
Frequency
|
60 Hz
|
|
Minimum Circuit Ampacity
|
25.19 A
|
|
Maximum Overcurrent Protection
|
40 A
|
|
Width
|
35-1/2 inches
|
|
Height
|
35-3/4 inches
|
|
Depth
|
35-1/2 inches
|
|
Weight
|
226 lbs
|
The GLXS4BA4810 condenser is only the outdoor section of a complete AC system. Proper indoor equipment matching, refrigerant compatibility, airflow, and electrical setup all play a role in final system performance.
GLXS4BA4810 Dimensions & Capacity
The Goodman GLXS4BA4810 has a nominal 4 ton capacity, which equals approximately 48,000 BTU of cooling per hour. The unit measures about 35.5 inches wide × 35.5 inches deep × 35.75 inches high, while the current shipping specifications list a packaged height of 39.75 inches and shipping weight of about 226 lbs.
A Goodman 4 ton AC unit can be appropriate for larger residential applications, but tonnage should not be selected from square footage alone. Insulation, windows, ceiling height, local climate, ductwork, sun exposure, and air leakage can all change the actual cooling demand.
A professional HVAC load calculation is the best way to determine whether a 48,000 BTU system is the right fit for a particular home.
Who Should Buy Goodman 4 Ton AC Unit?
The Goodman GLXS4BA4810 is best suited to homeowners who need a dedicated cooling-only condenser and whose property has been properly sized for a 4 ton system.
This model may be a good fit for:
-
Larger homes with a calculated 4 ton cooling requirement
-
Properties needing approximately 48,000 BTU of nominal cooling
-
Replacement of a compatible older central AC condenser
-
New split-system cooling configurations
-
Homes that already use a furnace or another separate heating source
-
Buyers specifically looking for an R32 central air conditioner
-
Applications where single-stage cooling is preferred
Because the GLXS4BA4810 is a cooling-only condenser, it does not provide heat-pump heating. Indoor equipment, airflow, electrical requirements, refrigerant compatibility, and system sizing should all be checked before selecting the unit.
FAQ
Q1: What is the cooling capacity of Goodman GLXS4BA4810?
The Goodman GLXS4BA4810 is a 4 ton condenser with approximately 48,000 BTU of nominal cooling capacity.
Q2: What SEER2 rating does GLXS4BA4810 have?
The product specification field lists the GLXS4BA4810 at up to 14.4 SEER2. Final efficiency depends on the complete matched HVAC system.
Q3: What refrigerant does Goodman GLXS4BA4810 use?
The GLXS4BA4810 uses R32 refrigerant and should be paired with compatible R32 indoor HVAC equipment.
Q4: Is Goodman GLXS4BA4810 a heat pump?
No. The GLXS4BA4810 is a cooling-only air conditioner condenser and does not provide reverse-cycle heating.
Q5: Is GLXS4BA4810 a complete AC system?
No. It is the outdoor condenser portion of a split air conditioning system. Compatible indoor equipment is required to create a complete central cooling system.
Explore Related Products