Trane Trane  |  SKU: GDK180A3SHA1DQY

Trane 15 Ton 182,000 BTU Commercial Gas/Electric Packaged Unit | High Heat | 14.0 IEER | R-454B | 208/230V 3-Phase | Foundation Series | Single Stage

Is this system right for you?

Width
86.9 in
Height
58 in
Depth
123.1 in
Weight
2300 lbs
V Voltage
208V/230V
Bundled
Purchase
All in
One Buy
Good for
Replacements

Need help with choosing a system or have other questions?Talk with one of our trusted HVAC professionals today!

Email us at : sales@acunitsforless.com

Call us at : 678-535-7176

 Physical Address : Unit 1284, 2210 Holly Springs Parkway, Holly Springs, Georgia 30142, United States

Call Or Text Us For Sale Price 678-535-7176

Reviews (39)

Shipping Policy

Once you place an order on AC units for less, we will promptly reach out to express our gratitude for your purchase and address any inquiries you may have. Our team will also review your order with you to ensure that you have selected the right equipment for your specific needs.

Order Process

Our order process includes a handling or production time in addition to the transit time. Delivery time = handling time + transit time.

Handling Time

All the products undergo a production process, so there will be a handling time of 2–3 business days from Monday to Friday. If your order is placed and payment is received after 2 p.m., then we will process the order the next business day.

Transit Time

Our shipping providers take 3-4 business days to deliver the order. It's an estimate, so there might be a delay.

Shipping Providers

We primarily use UPS or FEDEX for our deliveries. However, we reserve the right to use other carrier services as required to ensure efficient delivery. After an order ships, the shipping carrier will contact customers to coordinate the delivery schedule. 

Once an order has been processed and shipped, it's important to note that the shipping address cannot be altered. Items designated for pickup at the terminal will only be released to the individual listed on the shipping label. A valid driver's license and a signature will be required for the release of the shipment. We adhere strictly to this policy, with no exceptions.

Shipping Rates

We offer free shipping on all orders except for Flat Bed Shipping or Oversized items. Flat Bed Freight Shipping applies to units larger than 7.5 tons. These items will be delivered via flat bed truck and may require additional delivery coordination. Flat rate charges will be shown at checkout for eligible item. Hot Point PTAC items if ordered under 8 Units different freight is charged

Damages and shipping issues

At ACUnitsForLess.com, we are committed to providing our customers with a superior buying experience. We offer free crating to safeguard your equipment during transit, thus eliminating any concerns regarding damage. When you compare our shipping policy to that of our competitors, you'll notice the difference. Customers are not held accountable for any damage to their orders. 

Please make your purchase with confidence, knowing that we will ensure you receive the correct equipment that is brand new and in perfect condition.

How do I handle a return shipment?

You may return your unopened order within 60 days for a refund, minus shipping costs and a 25% restocking fee. Customers will be responsible for return shipping costs. Please keep your original box for shipping.

Cancellation

All orders cancelled after 6 hours from the confirmation email will follow the  return process,  whether or not your order has been shipped. If your order has shipped, you (the buyer) will also be responsible for return shipping charges. Refunds will be issued to the original credit card.

However, if you cancel the order before 6 hours, we will refund your full money.

To process the cancellation, please call us at +1  678-535-7176. We will not be available on Saturday and Sunday, so if somehow you have purchased a product on these days, then contact us on Monday before 3 pm.

If you need any help, feel free to contact us

Address : Unit 1284, 2210 Holly Springs Parkway, Holly Springs, Georgia, 30142, United States
E-Mail: sales@acunitsforless.com
Phone: +1  678-535-7176
Customer Service: Monday to Friday between 9:00 am to 5:00 pm.

Return Policy

If you are not entirely happy with your purchase, you can return your item/s within 60 days of delivery for a full refund of the original payment.

Once we have received the product(s) and, if appropriate, any packaging, a refund will be credited to the payment card account within two weeks; please note that it may take up to 3 days for your bank to credit your account. We are not liable and cannot take responsibility for any bank charges you may incur during the refund process.

Damages and issues

Please inspect your order upon reception and contact us immediately if the item is defective, damaged or if you receive the wrong item, so that we can evaluate the issue and make it right. In this case, we will cover the cost of return shipping as well as we will not charge any restocking fee.

Exchanges

The fastest way to ensure you get what you want is to return the item you have, and once the return is accepted, make a separate purchase for the new item. The cost of return shipping is the responsibility of the customer if you want to Exchange. Also we will charge 25% restocking fee.

Return Eligibility

Your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging to be eligible for a return. You’ll also need the receipt or proof of purchase.

Non-returnable items

The following items are not eligible for return:

  • Items that weren't returned within 60 days from the date the customer received the item
  • Items that have been used or damaged by the customer
  • Items that are not in their original packaging
  • Items that do not have all tags and accessories
  • Unfortunately, we cannot accept returns on sale items or gift cards.
  • Items that are consumable and  other wise stated cannot be returned examples are parts, compressors, misc items
  • Special order units
  • Custom-configured products
  • Commercial Units 
  • Consumable parts 
Return Costs

The cost of return shipping is the responsibility of the customer, except in the case of items that were damaged in transit. In that case, we will cover the cost of return shipping.

Restocking Fee

We charge 25% Restocking Fee, except product got damaged by carrier.

To start a return, you can contact us at sales@acunitsforless.com. If your return is accepted, we’ll send you a return shipping label and instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted.

Cancelled Orders

An order that has shipped cannot be cancelled. If you refuse an order which has already been shipped, not due to damage, you will be responsible for paying an ORDER RETURN FEE. We incur a fee from the freight carrier to return items that have been shipped, this fee is dependent on the item refused and the destination location.

Built-to-Order Items

There are no returns allowed for products which have been specially built for you and shipped by the manufacturer. These items are not routinely stocked at our warehouse and therefore cannot be returned.

Final Sale Policy

 By placing an order, the purchaser expressly acknowledges and agrees to the following terms:

1. No Returns or Exchanges
Final sale items are not eligible for return, exchange, substitution, or store credit for any reason, including but not limited to dissatisfaction, incorrect selection, incompatibility, or change of mind.

2. No Refunds
All sales of final sale items are final and non-refundable. Once an order is placed, it cannot be canceled, modified, or refunded.

3. Assumption of Risk
The purchaser assumes full responsibility for determining product suitability, compatibility, and compliance with applicable codes, regulations, and intended use prior to purchase.

4. Condition and Disclaimer
Final sale items are sold “AS IS” and “WITH ALL FAULTS” with no representations or warranties, express or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement, except where prohibited by law.

5. Shipping and Damage Claims
Any damage occurring during transit must be reported in writing within 48 hours of delivery with supporting photographs. Failure to report within this period constitutes acceptance of the product.

6. Chargebacks and Disputes
The purchaser agrees not to initiate any chargebacks or payment disputes related to final sale items. Any chargeback initiated in violation of this policy may be contested with the payment processor using this agreement as evidence.

7. Severability
If any provision of this policy is deemed unenforceable under applicable law, the remaining provisions shall remain in full force and effect.

If you need any help, feel free to contact us

Address: Unit 1284, 2210 Holly Springs Parkway, Holly Springs, Georgia, 30142, United States
E-Mail: sales@acunitsforless.com
Phone: +1  678-535-7176
Customer Service: Monday to Friday between 9:00 am to 5:00 pm.

Refund Policy

We provide a 60-day return policy for your convenience. To initiate a return, it is essential that the items remain unused and in their original manufacturer's packaging. When returning the equipment, please ensure that you reuse all shipping materials that were initially used to protect the equipment during shipment.

We will provide the return label.

Upon receiving your return, we will issue a refund for the full order amount, minus the return shipping cost and a 25% restocking fee.

Final Sale Policy

 By placing an order, the purchaser expressly acknowledges and agrees to the following terms:

1. No Returns or Exchanges
Final sale items are not eligible for return, exchange, substitution, or store credit for any reason, including but not limited to dissatisfaction, incorrect selection, incompatibility, or change of mind.

2. No Refunds
All sales of final sale items are final and non-refundable. Once an order is placed, it cannot be canceled, modified, or refunded.

3. Assumption of Risk
The purchaser assumes full responsibility for determining product suitability, compatibility, and compliance with applicable codes, regulations, and intended use prior to purchase.

4. Condition and Disclaimer
Final sale items are sold “AS IS” and “WITH ALL FAULTS” with no representations or warranties, express or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement, except where prohibited by law.

5. Shipping and Damage Claims
Any damage occurring during transit must be reported in writing within 48 hours of delivery with supporting photographs. Failure to report within this period constitutes acceptance of the product.

6. Chargebacks and Disputes
The purchaser agrees not to initiate any chargebacks or payment disputes related to final sale items. Any chargeback initiated in violation of this policy may be contested with the payment processor using this agreement as evidence.

7. Severability
If any provision of this policy is deemed unenforceable under applicable law, the remaining provisions shall remain in full force and effect.

genuine_parts

IMPORTANT: HVAC and Water Heater parts and accessories should only be installed by qualified technicians. Failure to understand and follow the manufacturer’s installation and use instructions may result in fire or explosion, electric shock, property damage, injury or loss of life. It is your responsibility to seek professional advice when installing and using these parts and accessories.

Trane Foundation Series 15 Ton Commercial Gas/Electric Packaged Unit — 208/230V High Heat for High-Capacity Cold Climate Commercial Buildings

The Trane Foundation Series 15-ton unit in high heat configuration on 208/230V 3-phase power is the step-up specification for cold climate commercial buildings where 12.5 tons no longer covers the cooling load and medium heat output falls critically short of winter heating demands. At 182,000 BTU on standard commercial voltage with high heat gas output, this commercial rooftop packaged unit is built for large retail centers, major office buildings, substantial institutional facilities, large houses of worship, schools, and high-occupancy commercial buildings in cold climate zones — the upper Midwest, New England, Mountain West, and Great Plains markets — where the cooling load has grown beyond the 12.5-ton ceiling and winter heating demands are severe enough that only maximum gas heat output keeps the building comfortable and protected through peak cold conditions. When step-up cooling capacity at 15 tons and maximum winter heat output are both non-negotiable in a cold climate building on standard commercial voltage, this is the configuration that delivers both simultaneously.

The high heat configuration at 15-ton capacity on 208/230V power opens the upper tier of the Foundation Series cold climate lineup on standard voltage — the first step beyond the 12.5-ton high heat entries that completed the lower tier, now carrying maximum gas heat output into the larger commercial building profile that 15-ton cooling capacity addresses. At 182,000 BTU cooling output, the buildings that specify this unit are genuinely large cold climate commercial facilities — high internal heat loads combined with substantial exterior envelope exposure, high infiltration in cold climate winters, and the extended heating degree days that northern U.S. markets generate across long heating seasons that can run six months or more. For these buildings, high heat at 15-ton capacity is not an optional upgrade over medium heat — it is the specification that determines whether the building maintains occupant comfort and building safety through the coldest sustained conditions of a genuine northern U.S. winter at a scale where heating system shortfalls affect large occupied areas simultaneously. Specifying high heat at installation at this tonnage eliminates the most disruptive and costly alternative a large cold climate commercial building faces: supplemental heating systems retrofitted to cover a medium heat shortfall on a 15-ton rooftop unit already in service.

At 14.0 IEER and R-454B refrigerant, this unit delivers full commercial energy code compliance and complete refrigerant future-proofing at the 15-ton high heat tier on standard commercial voltage. The 14.0 IEER at 15-ton capacity is consistent with the Foundation Series efficiency standard at this tonnage tier across all heat configurations — high heat specification carries no cooling efficiency penalty at 15-ton capacity, and building owners in cold climate zones get maximum winter heat output and full energy code compliance on the cooling side in the same factory-assembled package. For large cold climate commercial buildings on standard voltage holding rooftop equipment through 15 to 20-year service lives that accumulate higher annual operating hours than moderate or warm climate installations, R-454B at installation eliminates the mid-lifecycle refrigerant retrofit risk across extended cold climate service — the single most disruptive and costly mid-lifecycle event a 15-ton commercial rooftop unit can generate in a large cold climate building.

Specifications at a Glance

Spec Detail
Capacity 15 Ton / 182,000 BTU
Heat Configuration High Heat
IEER 14.0
Refrigerant R-454B
Voltage 208/230V
Phase 3-Phase
Heating Gas
Cooling Electric
Stages Single Stage
Series Foundation Series