The Goodman 5 Ton Split AC GLXS5BA6010 delivers powerful, efficient cooling in large residential and light commercial settings. Featuring a two-stage scroll compressor and eco-friendly R‑32 refrigerant, this split-system unit offers balanced performance, improved comfort, and reduced environmental impact with an impressive 15.2 SEER2 rating
Key Features
-
Two‑Stage Scroll Compressor – Offers smooth transitions between low and high cooling stages, enhancing energy efficiency and comfort control.
-
15.2 SEER2 Efficiency – Exceeds current energy standards, helping reduce utility costs in both cooling and partially with heat pumps.
-
R‑32 Refrigerant – Low global warming potential for more environmentally responsible operation.
-
Factory‑Installed Filter Drier – Protects internal components by removing moisture and debris.
-
Heavy‑Gauge Steel Cabinet – Built to stand up to outdoor elements, with a durable baked powder-coat finish.
-
Service‑Friendly Access Panels – Top and side panels simplify seasonal maintenance.
Design & Installation
-
Pre‑Charged for 15‑Foot Line Sets – Streamlines installation and reduces setup time.
-
Sweat‑Connection Service Valves with Gauge Ports – Supports easy refrigerant charging and diagnostic access.
-
Large‑Capacity Design – Ideal for cooling large living areas or smaller commercial spaces efficiently.
-
AHRI Certified & ETL Listed – Meets rigorous safety and performance standards.
Performance & Compatibility
The Goodman 15.2 SEER2 R‑32 Two‑Stage AC pairs seamlessly with matched indoor air handlers or coils to create a complete, efficient split-system. Perfect for new installations or replacing older units, this model ensures quiet operation, balanced airflow, and dependable comfort in larger spaces.
📌 Explore more Goodman models:
Goodman R32 Air Conditioners
Goodman Air Conditioners
Product Specification Table
Brand | Goodman |
Model # | GLXS5BA6010 |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | 5.0 Ton |
Coil Type | |
Total Indoor Unit(s) BTU | |
Voltage Requirements | |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | |
Indoor Unit BTUs | |
Zone/Rooms | |
AHRI No | GLXS5BA6010 |
Burner Stages | |
Cabinet Width | |
Airflow Direction | |
Furnace Efficiency / AFUE | |
Furnace BTU | |
Power Phase ( Single/Three) | |
Dimensions - (Shipping Unit Width) | 37.00 in |
Dimensions - (Shipping Unit Height) | 44.00 in |
Dimensions - (Shipping Unit Depth) | |
Weight - (Shipping Unit) | 297.000 lb |
Refrigerant Pre-Charged Line Length | 15 ft |
Power Frequency | 60 Hz |
Nom. CFM | |
Motor Speed Type | 0 |
MOCP | |
Min. Circuit Amps | 36.4 A |
Min Voltage | 0 |
Max Voltage | 0 |
Max Overcurrent Protection | 60 A |
LoNox | |
Valve Size Suction (O.D.) | 7/8 in |
Valve Size Liquid (O.D.) | 3/8 in |
Liquid Line Size | |
Energy Source | 0 |
Expansion Device | 0 |
Decibels (dBA) | 75.6 dBA |
Compressor Type | Scroll |
Compressor Stages | Two Stage |
Cased vs Uncased | |
Heating Capacity - (Nominal) | 0 |
Cooling Capacity - (Nominal) | 0 |
Airflow Rate High Cooling | |
Function Category | Split Air Conditioner |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |
Reliable indoor cooling component for large HVAC systems. The Goodman CAPTA6030D3 evaporator coil is designed for upflow or downflow installation and uses eco-friendly R‑32 refrigerant. Paired with outdoor 5 Ton condensers or heat pumps, it ensures efficient refrigerant management and optimal system performance in residential and light-commercial applications.
Key Features & Performance
-
TXV Expansion Valve – Maintains precise refrigerant flow and maximizes cooling efficiency.
-
R‑32 Refrigerant Compatibility – Supports modern, environmentally conscious HVAC systems.
-
Cased Multi-Position Design – Can be installed in upflow or downflow orientations to suit diverse duct and cabinet layouts.
-
Durable Cabinet Construction – Encased in robust, insulated housing built for reliable operation.
-
Optimized for 5 Ton Systems – Engineered to match capacity and refrigerant charge requirements of large HVAC setups.
Specifications
-
System Compatibility: 5 Ton split-system condensers or heat pumps
-
Refrigerant: R‑32
-
Expansion Device: Thermostatic Expansion Valve (TXV)
-
Installation Orientation: Upflow or Downflow
-
Casing: Fully cased, insulated steel housing
Installation & Compatibility
- Designed for straightforward connection to outdoor condensers or heat pumps in full HVAC systems
- Multi-position flexibility allows seamless integration into existing ductwork or new installations
Looking for a reliable and efficient heating solution?
Explore our full range of Goodman HVAC products designed for comfort and energy efficiency.
Product Specification Table
Brand | Goodman |
Model # | CAPTA6030D3 |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | 5.0 Ton |
Coil Type | Upflow/Downflow |
Total Indoor Unit(s) BTU | |
Voltage Requirements | |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | |
Indoor Unit BTUs | |
Zone/Rooms | |
AHRI No | CAPTA6030D3 |
Burner Stages | |
Cabinet Width | |
Airflow Direction | Upflow |
Furnace Efficiency / AFUE | |
Furnace BTU | |
Power Phase ( Single/Three) | |
Dimensions - (Shipping Unit Width) | 26.75 in |
Dimensions - (Shipping Unit Height) | 32.25 in |
Dimensions - (Shipping Unit Depth) | |
Weight - (Shipping Unit) | 70 lb |
Refrigerant Pre-Charged Line Length | 0 |
Power Frequency | 0 |
Nom. CFM | |
Motor Speed Type | 0 |
MOCP | |
Min. Circuit Amps | 0 |
Min Voltage | 0 |
Max Voltage | 0 |
Max Overcurrent Protection | 0 |
LoNox | |
Valve Size Suction (O.D.) | 0 |
Valve Size Liquid (O.D.) | 0 |
Liquid Line Size | |
Energy Source | 0 |
Expansion Device | TXV |
Decibels (dBA) | 0 |
Compressor Type | 0 |
Compressor Stages | 0 |
Cased vs Uncased | |
Heating Capacity - (Nominal) | 0 |
Cooling Capacity - (Nominal) | 0 |
Airflow Rate High Cooling | |
Function Category | |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |
Goodman GR9S800805CX – AFUE Gas Furnace with Nine Speed ECM & Low NOx Compliance
Goodman 80% AFUE Gas Furnace Nine Speed ECM, Single Stage, GR9S800403AN
The Goodman GR9S800805CX is a high-efficiency AFUE gas furnace engineered for reliable comfort, energy savings, and smooth operation. Featuring a Nine Speed ECM blower motor and Low NOx compliance, this Goodman AFUE Gas Furnace ensures quiet performance, consistent heat distribution, and cleaner emissions—ideal for environmentally conscious homes.
Built with a rugged aluminized-steel tubular heat exchanger and a durable Silicon Nitride igniter, this unit offers dependable performance through the toughest winters. Whether you're replacing an old furnace or upgrading your HVAC system, the GR9S800805CX delivers lasting value and efficiency with an 80% AFUE rating.
Key Specifications – GR9S800805CX:
-
Model: Goodman GR9S800805CX
-
AFUE Efficiency: 80%
-
Input Capacity: 80,000 BTU
-
Output Capacity: 64,000 BTU
-
Motor Type: Nine Speed ECM
-
Airflow (High Heating): 1270 CFM
-
Gas Valve: Single-Stage
-
Igniter: Long-life Silicon Nitride
-
Power Supply: 115V / 60Hz / Single Phase
-
Unit Dimensions (W x D x H): 21" x 28" x 33-3/8"
-
Weight: 132 lbs
-
Category: Indoor Gas Furnace
-
Emissions Compliance: Low NOx
Product Benefits
- ✔ Heavy-duty tubular heat exchanger for enhanced durability and heat transfer
- ✔ Multi-speed ECM blower motor with continuous fan for quiet and even airflow
- ✔ Self-diagnostic control board with constant memory for easy troubleshooting
- ✔ Pre-configured for air cleaner & humidifier support
- ✔ Color-coded low-voltage terminals for easier installation
- ✔ Quiet operation with a single-speed inducer draft blower
- ✔ Reliable ignition with the advanced Silicon Nitride igniter
Warranty Coverage
Residential (Registered)
- Heat Exchanger: Lifetime Warranty
- All Parts: 10 Years
Residential (Standard)
- Heat Exchanger: 20 Years
- All Parts: 5 Years
Multi-Family / Commercial
- Heat Exchanger: 20 Years
- All Parts: 5–10 Years (based on registration)
The Goodman GR9S800805CX offers a balance of affordability, performance, and eco-conscious operation. Its AFUE 80 efficiency, Nine Speed ECM technology, and Low NOx emission rating make it an excellent choice for homeowners looking for comfort without compromise.
Documents:
Product Specification Table
Brand | Goodman |
Model # | GR9S800805CX |
SEER2/EER2 | |
Refrigerant | R-32 |
Tonnage | |
Coil Type | |
Total Indoor Unit(s) BTU | 80000 |
Voltage Requirements | 110V To 120 V |
Series | |
Coverage Area (Sq. Ft) | |
Indoor Mount Type | Wall Mount |
Indoor Unit BTUs | 80K |
Zone/Rooms | |
AHRI No | GR9S800805CX |
Burner Stages | Single Stage |
Cabinet Width | 21" |
Airflow Direction | Upflow |
Furnace Efficiency / AFUE | 80% |
Furnace BTU | 80,000 BTU's |
Power Phase ( Single/Three) | 1 Ph |
Dimensions - (Shipping Unit Width) | #N/A |
Dimensions - (Shipping Unit Height) | #N/A |
Dimensions - (Shipping Unit Depth) | |
Weight - (Shipping Unit) | |
Refrigerant Pre-Charged Line Length | |
Power Frequency | 60 Hz |
Nom. CFM | |
Motor Speed Type | #N/A |
MOCP | |
Min. Circuit Amps | #N/A |
Min Voltage | |
Max Voltage | |
Max Overcurrent Protection | #N/A |
LoNox | |
Valve Size Suction (O.D.) | |
Valve Size Liquid (O.D.) | |
Liquid Line Size | |
Energy Source | |
Expansion Device | |
Decibels (dBA) | |
Compressor Type | |
Compressor Stages | |
Cased vs Uncased | |
Heating Capacity - (Nominal) | |
Cooling Capacity - (Nominal) | |
Airflow Rate High Cooling | |
Function Category | Gas Furnace |
Package System Type | |
Air Handler Mount Type System | |
Split System Type | |