    Liquid Cooling Fluids for Data Centers, AI and HPC

    Rack densities have outgrown air cooling. Whether you are filling a coolant distribution unit (CDU) for direct-to-chip cold plates or charging a chilled-water loop that serves CRAHs and dry coolers, the fluid in the loop decides how long the equipment lasts. ACUnitsForLess stocks Dynalene heat transfer fluids engineered for data center service, in pails, drums and totes shipped to all 48 contiguous states.

    Direct-to-Chip (DTC) Coolants

    The Dynalene PG-D Series is a pre-diluted USP propylene glycol coolant built for technology cooling system (TCS) loops, CDUs and copper cold plates. PG-D25 is accepted by the Open Compute Project (OCP). The series passes ASTM D8040 (heat transfer coolant corrosion), D7437 (thermal stability) and D1881 (foaming).

    • PG-D15 – 15% PG with biocide, freeze point 23Β°F, for indoor loops with no freeze exposure
    • PG-D25 – 25% PG, freeze point 14Β°F, the OCP-accepted standard for cold plate loops
    • PG-D55 – 55% PG for loops that run to outdoor dry coolers in cold climates

    Aluminum-Safe OAT Glycols

    Standard inhibited glycols can gel, drop white precipitate or spike pH in contact with hot aluminum. Dynalene PG-A1 and EG-A1 use an organic acid technology (OAT) inhibitor package that protects aluminum up to 239Β°F surface temperature, making them the right fill for aluminum cold plates, microchannel dry coolers and mixed-metal loops.

    Inhibited Glycols for Chiller and Facility Water Loops

    Dynalene PG (non-toxic propylene glycol) and Dynalene EG (ethylene glycol) are virgin-glycol heat transfer fluids with a corrosion inhibitor package for steel, copper, brass and cast iron. Use them in chillers, facility water systems (FWS), cooling towers, and freeze protection for rooftop and outdoor piping.

    Which Fluid Do I Need?

    Application Recommended Fluid
    CDU / cold plate loop (TCS), copper and stainless PG-D25 (or PG-D15 indoors)
    Cold plate or CDU loop with aluminum components PG-A1 or EG-A1
    Loop running to outdoor dry coolers in freezing climates PG-D55, PG-A1 or EG-A1 at 40–50%
    Chilled-water plant / facility water system Dynalene PG or EG
    Aluminum microchannel dry cooler or coil PG-A1 or EG-A1

    Why Buy Coolant from ACUnitsForLess

    • Pre-mixed fluids – no on-site blending, no tap-water contamination
    • Pails for top-offs, drums and totes for initial fills
    • Contractor pricing through our B2B portal
    • Tanker quantities quoted on request – call 678-535-7176

    Always confirm fluid selection against your CDU or chiller manufacturer's requirements. Do not mix glycol types or inhibitor chemistries in the same loop.