Light Commercial Packaged Heat Pump

(41 productos)

Shop light commercial packaged heat pumps from 3 to 10 tons. A packaged heat pump puts the compressor, both coils and the blower in one outdoor cabinet. It heats and cools a building from a single rooftop or ground-level unit, with no separate indoor air handler. Every unit in this collection is a Daikin R-32 model, available in 208/230V single-phase, 208/230V three-phase, 460V and 575V.

Leer más Leer menos

Not sure which unit fits your job? Call 678-535-7176, or see contractor pricing in our B2B portal.

Daikin packaged heat pump series

Series Sizes Voltages Best for
DSH standard efficiency 3, 4, 5, 6, 7.5, 8.5 and 10 ton 208/230V 1-ph (3–5 ton), 208/230V 3-ph, 460V, 575V Retail, office and light-industrial rooftop jobs. The widest size range, plus high-static 6-ton models.
DHH high efficiency 3, 4, 5 and 6 ton 208/230V 1-ph (3 and 5 ton), 208/230V 3-ph, 460V, 575V Buildings with long run hours, where lower operating cost pays back. The 3-ton single-phase unit is rated 16.4 SEER2.
DP3HM multi-position 3, 4 and 5 ton 208/230V 3-ph Small commercial spaces with three-phase power that need horizontal or downflow duct connections. 13.4 SEER2; the 5-ton is two-stage.

Looking for variable-speed units? See Daikin commercial inverter packaged heat pumps. For the full Daikin line, including direct-drive DFH models, see all Daikin commercial packaged heat pumps.

How to read a Daikin packaged model number

Example: DSH0363D000001S

  • DSH = series (DSH standard, DHH high efficiency)
  • 036 = nominal cooling capacity in thousands of BTU/h (036 = 3 ton, 060 = 5 ton, 120 = 10 ton)
  • 3 = voltage: 1 = 208/230V 1-phase, 3 = 208/230V 3-phase, 4 = 460V 3-phase, 7 = 575V 3-phase
  • W in place of D (for example DSH0723W) = high-static blower option

How to choose a commercial packaged heat pump

  • Size it to the load. A rule of thumb is not enough for commercial space. Occupancy, lighting, equipment and outside air all add load. Have a Manual N or equivalent load calculation done, or start with our Sizing Estimator.
  • Match the building's power. Check the electrical service before you order. Single-phase is common in small buildings and converted homes. Most commercial buildings have 208/230V three-phase or 460V, and 575V is mostly used in Canada and some industrial sites.
  • Plan for backup heat. In colder climates, add electric heat. Daikin heat strips install in the unit and carry the load when outdoor temperatures drop.
  • Order the curb and accessories together. A new rooftop install needs a Daikin roof curb. If code requires fresh air, or you want free cooling in mild weather, add an economizer.
  • Check static pressure. Long duct runs or high-MERV filters may need a high-static (W) model.

Packaged heat pump vs. other commercial options

  • Packaged heat pump: electric heating and cooling in one cabinet. Best where there's no gas or where an all-electric building is the goal.
  • Packaged gas/electric unit: gas heat with electric cooling. Better for cold climates with low-cost natural gas.
  • Packaged air conditioner: cooling only, for spaces heated another way.
  • Light commercial split heat pump: an outdoor unit plus an indoor air handler, for buildings without roof access or with an indoor mechanical room.

Frequently asked questions

What is a light commercial packaged heat pump?

It's a single outdoor unit, usually 3 to 10 tons, that heats and cools a building by moving heat in either direction. All major components are factory-built into one cabinet, which sits on a roof curb or a ground pad and connects to the supply and return ducts.

Can I use a packaged heat pump on a home?

Yes. The 3 to 5 ton single-phase models run on standard 208/230V residential power and are often used on homes and manufactured housing without room for an indoor unit.

Why R-32?

R-32 has a much lower global warming potential than R-410A and meets the current U.S. refrigerant rules for new equipment. Service tools and parts must be rated for R-32.

Do I need a roof curb?

For a new rooftop install, yes. The curb supports the unit, seals the roof opening and lines up the duct connections. Replacements can often reuse the existing curb, or use an adapter curb if the footprint changed.

Do you ship commercial units?

Yes. Units ship by freight to the 48 contiguous states. Inspect the unit for damage before you sign for the delivery. Licensed contractors can get trade pricing through our contractor portal.

Related: Daikin commercial packaged heat pumps · Inverter packaged heat pumps · Commercial rooftop air conditioners · Roof curbs · Economizers · Heat strips

Ver como

    Light Commercial Packaged Heat Pump - acunitsforless.com

    Pedidos de múltiples unidades y de contratistas

    ¿Está comprando para más de una propiedad?

    Obtenga precios para contratistas en múltiples sistemas o llame a nuestro equipo y le ayudaremos a elegir el equipo adecuado para cada trabajo.

    best-in-comfort-less-in-price-desktop

    Gracias por su visita

    Haz clic en "Inicio" para volver a la pantalla de inicio

    Comparar /3

    Cargando...