{"product_id":"wrangler-wr-capea2418c3-2-ton-aluminum-coil-eev-upflow-downflow-18","title":"Wrangler WR-CAPEA2418C3 2 Ton Aluminum Coil EEV Upflow\/Downflow 18\"","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe WR-CAPEA2418C3 is a reliable 2-ton evaporator coil that is suitable for R-32 refrigerant-based HVAC systems. Designed for both upflow and downflow installations, this coil comes with a factory-mounted electronic expansion valve (EEV) in addition to a fully aluminum coil assembly. It offers efficient heat transfer and reliable performance for residential HVAC systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe WR-CAPEA2418C3 is an evaporator coil case. A designed for split HVAC systems that need an upflow or downflow evaporator airflow configuration. With a protective cabinet structure, the evaporator coil case A maintains consistent airflow and protects the internal components. This evaporator coil case A is built with an aluminum coil, sinks, and tubes to increase heat transfer efficiency. The electronic expansion valve (EEV) found in this model is designed for accurate control of refrigerant flow. This helps maintain conditioned spaces at the desired temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eQuick Facts\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eModel \/ SKU:\u003c\/span\u003e\u003cspan\u003e WR-CAPEA2418C3\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eNominal Capacity:\u003c\/span\u003e\u003cspan\u003e 2 Ton\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eRefrigerant Type:\u003c\/span\u003e\u003cspan\u003e R-32\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eCoil Type:\u003c\/span\u003e\u003cspan\u003e Cased A-Coil Evaporator\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eInstallation Configuration:\u003c\/span\u003e\u003cspan\u003e Upflow \/ Downflow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eCoil Construction:\u003c\/span\u003e\u003cspan\u003e All-Aluminum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eApplication:\u003c\/span\u003e\u003cspan\u003e Residential HVAC Systems\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eSuction Line Size:\u003c\/span\u003e\u003cspan\u003e 3\/4\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eLiquid Line Size:\u003c\/span\u003e\u003cspan\u003e 3\/8\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cspan\u003eDimensions (W × H × D):\u003c\/span\u003e\u003cspan\u003e Approx. \u003c\/span\u003e\u003cspan\u003e21″ × 18″ × 21″\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCapacity \u0026amp; Coverage\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis coil is designed for HVAC systems that require 2 tons of cooling capacity. This coil will serve well in residential homes and small-sized HVAC systems. The flexible and diverse Downflow\/ Upflow installation makes this coil easy to integrate into variable ductwork. The WR-CAPEA2418C3 evaporator coil works well with compatible outdoor units. This coil is best used in 1st fit-out projects or replacement projects for new HVAC units to ensure added cooling capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEvaporator coil WR-CAPEA2418C3 is designed to operate efficiently with R-32 refrigerant in HVAC units. This is the best choice for excellent heat transfer with lesser corrosion as compared to aluminum copper used in coils of evaporator units. The electronic expansion valve (EEV) is used to control the amount of refrigerant and helps to maintain cooling cycles and airflow in a steady state.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eConstruction \u0026amp; Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe cabinet structure of the WR-CAPEA2418C3 is fabricated to withstand rough handling and to protect internal mechanisms during shipping, there is a provision for ensuring the steady flow of air to the warm side coil and to the cold side coil, ensuring that the coil operates under optimal thermal conditions for as long as possible. It is constructed of aluminum throughout; this provides long-term durability as well as improved thermal performance. The insulated cabinet of the coil is constructed to ensure that the operational flow of air remains steady, and the corrosion-protected drain pan is built to facilitate a steady flow of liquid that is evaporated from the condensation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eInstallation \u0026amp; Application\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe WR-CAPEA2418C3 is made for the purpose of interfacing with HVAC systems that utilize R-32 refrigerants, and it is designed for interfacing with systems in either the upflow direction or the downflow direction. Provision is made for standard suction and liquid line connections, and this enhances the ability for integration with the HVAC equipment that is provided. Additionally, the design of the cased cabinet yields more ease of access for the performance of service or inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eNoise \u0026amp; Comfort\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe WR-CAPEA2418C3 coil is designed to ensure that the operation of the system is quiet. This is achieved through the provision of airflow that is balanced throughout the system, as well as the steady distribution of refrigerant through the entire system. This results in the attainment of lower temperatures, thereby increasing comfort in the conditioned space.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eQ1: \u003c\/span\u003e\u003cspan\u003eWhat refrigerant does the Wrangler WR-CAPEA2418C3 use?\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e A: The \u003c\/span\u003e\u003cspan\u003eWR-CAPEA2418C3\u003c\/span\u003e\u003cspan\u003e is designed specifically for \u003c\/span\u003e\u003cspan\u003eR-32 refrigerant HVAC systems\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eQ2: \u003c\/span\u003e\u003cspan\u003eDoes this evaporator coil include an EEV?\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e A: \u003c\/span\u003e\u003cspan\u003eYes, it has a factory-installed electronic expansion valve (EEV) for refrigerant control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eQ3: \u003c\/span\u003e\u003cspan\u003eWhat installation configurations are supported?\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e A: \u003c\/span\u003e\u003cspan\u003eThis coil supports both upflow and downflow configurations of the HVAC installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eExplore More\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003ca href=\"https:\/\/www.acunitsforless.com\/products\/wrangler-wr-capta1818a3-1-5-ton-cased-evaporator-coil-txv-upflow-downflow?_pos=1\u0026amp;_psq=Wrangler+WR-CAPTA1818A3+1.5+Ton+Cased+Evaporator+Coil\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e\u003cspan\u003eWrangler WR-CAPTA1818A3 1.5 Ton Cased Evaporator Coil\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" role=\"presentation\"\u003e\u003ca href=\"https:\/\/www.acunitsforless.com\/products\/wrangler-2-5-ton-cased-coil-wr-capta3026c3-r-32-txv-upflow-downflow?_pos=1\u0026amp;_psq=WR-CAPTA3026C3\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e\u003cspan\u003eWrangler WR-CAPTA3026C3 2.5 Ton Cased Evaporator Coil\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.acunitsforless.com\/products\/wrangler-3-ton-cased-coil-wr-capta3626c3-r-32-txv-upflow-downflow?_pos=1\u0026amp;_psq=WR-CAPTA3626C3\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eWrangler WR-CAPTA3626C3 3 Ton Cased Evaporator Coil\u003c\/a\u003e\u003cb id=\"docs-internal-guid-2538aefb-7fff-9abb-8da0-c0fa0949b0de\"\u003e\u003ca href=\"https:\/\/www.acunitsforless.com\/products\/wrangler-3-ton-cased-coil-wr-capta3626c3-r-32-txv-upflow-downflow?_pos=1\u0026amp;_psq=WR-CAPTA3626C3\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Wrangler","offers":[{"title":"Default Title","offer_id":54546692014371,"sku":"WR-CAPEA2418C3","price":770.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/wrangler-wr-capea2418c3-2-ton-aluminum-coil-eev-upflowdownflow-18wrangleracunitsforless-3611560.png?v=1768334717","url":"https:\/\/www.acunitsforless.com\/products\/wrangler-wr-capea2418c3-2-ton-aluminum-coil-eev-upflow-downflow-18","provider":"acunitsforless.com","version":"1.0","type":"link"}