{"product_id":"trane-15-ton-commercial-gas-electric-packaged-unit-foundation-series-medium-heat-r454b-208-230v-3-phas","title":"Trane 15 Ton 182,000 BTU Commercial Gas\/Electric Packaged Unit | Medium Heat | 14.0 IEER | R-454B | 208\/230V 3-Phase | Foundation Series | Single Stage","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Trane Foundation Series 15-ton unit in medium heat configuration on 208\/230V 3-phase power is the step-up specification for large moderate climate commercial buildings where 12.5 tons no longer covers the cooling load and low heat output falls short of actual winter heating demand. At 182,000 BTU on standard commercial voltage with medium heat gas configuration, this commercial rooftop packaged unit is built for large retail centers, major office buildings, full-service restaurants, large houses of worship, schools, and substantial institutional facilities in moderate climate zones — the Mid-Atlantic, Pacific Northwest, lower Midwest, and transitional Southeast markets — where cooling loads are large enough to justify 15-ton capacity and winter heating demands are real enough to require more than low heat output but not severe enough to warrant high heat specification. Medium heat at 15-ton capacity is the correct call for the largest group of large commercial buildings across the broadest geographic band of the U.S. commercial market.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe medium heat configuration at 15-ton capacity on 208\/230V power positions this unit as the specification for large commercial buildings where the heat configuration decision is driven by geography and building envelope rather than tonnage alone. At 182,000 BTU cooling output, the buildings that specify this unit are genuinely large — high internal heat loads, significant exterior envelope exposure, and sustained peak cooling demand through warm months — but they operate in climates where winter conditions are moderate rather than severe, making medium heat the configuration that covers actual winter demand without the fuel consumption overhead of high heat in a building that will rarely if ever require maximum gas output through its heating season. For facility managers and building owners in moderate climate zones tracking operating costs across both heating and cooling seasons, medium heat at 15-ton capacity is the specification that delivers correct performance on both sides of the annual load profile without oversizing either system.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eAt 14.0 IEER and R-454B refrigerant, this unit delivers full commercial energy code compliance and complete refrigerant future-proofing at the 15-ton medium heat tier. For large moderate climate commercial buildings that hold rooftop equipment for 15 to 20 years through balanced annual operating cycles of meaningful heating and extended cooling, R-454B at installation is the specification that protects the building owner's investment across the full equipment service life — eliminating the mid-lifecycle refrigerant retrofit risk that will materialize for R-410A equipment well within the operational life of units being installed today. Single-stage operation at 15-ton capacity keeps commissioning clean and long-term service costs predictable at the tonnage tier where system availability matters most across both heating and cooling seasons in large moderate climate commercial buildings.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpecifications at a Glance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpec\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCapacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e15 Ton \/ 182,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeat Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMedium Heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIEER\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e14.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePhase\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eGas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eElectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStages\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFoundation Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Trane","offers":[{"title":"Default Title","offer_id":55231160451363,"sku":null,"price":21763.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/TraneGDK_9e5fd715-ae92-4ad3-860d-1ac9ce180485.png?v=1781331538","url":"https:\/\/www.acunitsforless.com\/products\/trane-15-ton-commercial-gas-electric-packaged-unit-foundation-series-medium-heat-r454b-208-230v-3-phas","provider":"acunitsforless.com","version":"1.0","type":"link"}