{"product_id":"mitsubishi-pac-ukprc001-cn-1-bacnet-and-modbus-interface","title":"Mitsubishi PAC-UKPRC001-CN-1 BACnet and Modbus Interface","description":"\u003cp\u003e\u003cstrong\u003eProduct: PAC-UKPRC001-CN-1\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"204\" data-end=\"587\"\u003eThe \u003cstrong data-start=\"208\" data-end=\"229\"\u003ePAC-UKPRC001-CN-1\u003c\/strong\u003e is a \u003cstrong data-start=\"235\" data-end=\"271\"\u003eBACnet \u0026amp; Modbus interface module\u003c\/strong\u003e designed by \u003cstrong data-start=\"327\" data-end=\"350\"\u003eMitsubishi Electric\u003c\/strong\u003e to \u003cstrong data-start=\"354\" data-end=\"447\"\u003eintegrate Mitsubishi indoor HVAC units with third-party Building Management Systems (BMS)\u003c\/strong\u003e. It enables external control and monitoring of indoor units through widely used automation protocols. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"589\" data-end=\"877\"\u003eThis module is typically installed on Mitsubishi Electric \u003cem data-start=\"647\" data-end=\"660\"\u003eCITY MULTI®\u003c\/em\u003e, \u003cem data-start=\"662\" data-end=\"672\"\u003eM-Series\u003c\/em\u003e, and \u003cem data-start=\"678\" data-end=\"688\"\u003eP-Series\u003c\/em\u003e indoor units, allowing a one-to-one connection between the indoor unit and a third-party automation or monitoring system via \u003cstrong data-start=\"814\" data-end=\"838\"\u003eRS-485 communication\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"884\" data-end=\"907\"\u003e Key Functionality\u003c\/h2\u003e\n\u003cul data-start=\"909\" data-end=\"1569\"\u003e\n\u003cli data-start=\"909\" data-end=\"1061\"\u003e\n\u003cp data-start=\"911\" data-end=\"1061\"\u003e\u003cstrong data-start=\"911\" data-end=\"931\"\u003eBMS Integration:\u003c\/strong\u003e Connects Mitsubishi indoor units to a building management system for centralized control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1062\" data-end=\"1244\"\u003e\n\u003cp data-start=\"1064\" data-end=\"1244\"\u003e\u003cstrong data-start=\"1064\" data-end=\"1090\"\u003eDual Protocol Support:\u003c\/strong\u003e Supports \u003cstrong data-start=\"1100\" data-end=\"1116\"\u003eBACnet® MSTP\u003c\/strong\u003e and \u003cstrong data-start=\"1121\" data-end=\"1136\"\u003eModbus® RTU\u003c\/strong\u003e communication protocols over RS-485 for flexibility in integration. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1245\" data-end=\"1383\"\u003e\n\u003cp data-start=\"1247\" data-end=\"1383\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1271\"\u003eOne Module Per Unit:\u003c\/strong\u003e Requires one interface module for each indoor unit you want to control. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1386\" data-end=\"1569\"\u003e\u003cstrong data-start=\"1386\" data-end=\"1405\"\u003eLED Indicators:\u003c\/strong\u003e Provides visual feedback on communication status between the interface, the indoor unit, and the building management network. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1576\" data-end=\"1606\"\u003e Specifications\u003c\/h2\u003e\n\u003cp data-start=\"1608\" data-end=\"1640\"\u003e\u003cstrong data-start=\"1608\" data-end=\"1638\"\u003eElectrical \u0026amp; Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1641\" data-end=\"2194\"\u003e\n\u003cli data-start=\"1641\" data-end=\"1758\"\u003e\n\u003cp data-start=\"1643\" data-end=\"1758\"\u003e\u003cstrong data-start=\"1643\" data-end=\"1660\"\u003ePower Supply:\u003c\/strong\u003e 12 V DC, supplied from the indoor unit’s CN105 connector. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1759\" data-end=\"1921\"\u003e\n\u003cp data-start=\"1761\" data-end=\"1921\"\u003e\u003cstrong data-start=\"1761\" data-end=\"1789\"\u003eCommunication Interface:\u003c\/strong\u003e RS-485 supporting\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1922\" data-end=\"2041\"\u003e\n\u003cp data-start=\"1924\" data-end=\"2041\"\u003e\u003cstrong data-start=\"1924\" data-end=\"1951\"\u003eIndoor Unit Connection:\u003c\/strong\u003e CN105 IT terminal (for communications and power). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2042\" data-end=\"2194\"\u003e\n\u003cp data-start=\"2044\" data-end=\"2194\"\u003e\u003cstrong data-start=\"2044\" data-end=\"2062\"\u003eCompatibility:\u003c\/strong\u003e Suitable for Mitsubishi Electric \u003cem data-start=\"2096\" data-end=\"2119\"\u003eCITY MULTI\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54766532985123,"sku":"PAC-UKPRC001-CN-1","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/PAC-UKPRC001-CN-1.png?v=1771935130","url":"https:\/\/www.acunitsforless.com\/products\/mitsubishi-pac-ukprc001-cn-1-bacnet-and-modbus-interface","provider":"acunitsforless.com","version":"1.0","type":"link"}