{"product_id":"mitsubishi-msdd-50tr-e-m-series-branch-box-distribution-pipe","title":"Mitsubishi MSDD-50TR-E M-Series Branch Box Distribution Pipe","description":"\u003cp\u003e\u003cstrong\u003eProduct: MSDD-50TR-E\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"154\" data-end=\"506\"\u003eThe \u003cstrong data-start=\"158\" data-end=\"173\"\u003eMSDD-50TR-E\u003c\/strong\u003e is a \u003cstrong data-start=\"179\" data-end=\"214\"\u003edistribution pipe\/accessory kit\u003c\/strong\u003e designed for \u003cstrong data-start=\"228\" data-end=\"316\"\u003eMitsubishi Electric multi-system twin-type mini-split air conditioning installations\u003c\/strong\u003e. It’s used to \u003cstrong data-start=\"331\" data-end=\"355\"\u003eevenly split (50:50)\u003c\/strong\u003e the refrigerant flow from a compatible outdoor unit into \u003cstrong data-start=\"413\" data-end=\"438\"\u003etwo separate circuits\u003c\/strong\u003e for twin (dual-indoor) usage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"508\" data-end=\"781\"\u003eThis accessory is part of the refrigerant line set during installation of two indoor units connected to a single outdoor unit in a \u003cstrong data-start=\"639\" data-end=\"676\"\u003emulti-system (twin) configuration\u003c\/strong\u003e and uses \u003cstrong data-start=\"686\" data-end=\"712\"\u003eflare-type connections\u003c\/strong\u003e for simplified field assembly. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"783\" data-end=\"786\"\u003e\n\u003ch2 data-start=\"788\" data-end=\"812\"\u003e Key Specifications\u003c\/h2\u003e\n\u003cp data-start=\"814\" data-end=\"1801\"\u003e\u003cstrong data-start=\"814\" data-end=\"830\"\u003ePart Number:\u003c\/strong\u003e \u003cstrong data-start=\"831\" data-end=\"846\"\u003eMSDD-50TR-E\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cbr data-start=\"884\" data-end=\"887\"\u003e\u003cstrong data-start=\"887\" data-end=\"904\"\u003eProduct Type:\u003c\/strong\u003e \u003cstrong data-start=\"905\" data-end=\"972\"\u003eTwinning Distribution Pipe \/ Branch Pipe (Mini-Split Accessory)\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cbr data-start=\"1010\" data-end=\"1013\"\u003e\u003cstrong data-start=\"1013\" data-end=\"1029\"\u003eApplication:\u003c\/strong\u003e Used in \u003cstrong data-start=\"1038\" data-end=\"1083\"\u003emulti-system twin type (two indoor units)\u003c\/strong\u003e refrigerant distribution for split-type outdoor units from Mitsubishi Electric. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cbr data-start=\"1201\" data-end=\"1204\"\u003e\u003cstrong data-start=\"1204\" data-end=\"1227\"\u003eDistribution Ratio:\u003c\/strong\u003e \u003cstrong data-start=\"1228\" data-end=\"1237\"\u003e50:50\u003c\/strong\u003e — Outdoor unit’s refrigerant capacity is equally divided into two branches for two indoor units. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cbr data-start=\"1372\" data-end=\"1375\"\u003e\u003cstrong data-start=\"1375\" data-end=\"1395\"\u003eConnection Type:\u003c\/strong\u003e \u003cstrong data-start=\"1396\" data-end=\"1418\"\u003eFlared connections\u003c\/strong\u003e (no brazing required) — stacks with flare nuts and joint pipes provided. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cbr data-start=\"1529\" data-end=\"1532\"\u003e\u003cstrong data-start=\"1532\" data-end=\"1550\"\u003ePipe Material:\u003c\/strong\u003e \u003cstrong data-start=\"1551\" data-end=\"1582\"\u003ePhosphate deoxidized copper\u003c\/strong\u003e (JIS H3300, C1220T-OL) for both liquid and gas pipes. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003cbr data-start=\"1674\" data-end=\"1677\"\u003e\u003cstrong data-start=\"1677\" data-end=\"1692\"\u003eInsulation:\u003c\/strong\u003e Styrofoam molded pipe covers included for both liquid and gas lines. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1803\" data-end=\"1806\"\u003e\n\u003ch2 data-start=\"1808\" data-end=\"1837\"\u003e Components \u0026amp; Dimensions\u003c\/h2\u003e\n\u003cul data-start=\"1839\" data-end=\"2373\"\u003e\n\u003cli data-start=\"1839\" data-end=\"1952\"\u003e\n\u003cp data-start=\"1841\" data-end=\"1952\"\u003e\u003cstrong data-start=\"1841\" data-end=\"1870\"\u003eLiquid Distribution Pipe:\u003c\/strong\u003e One line for dividing liquid refrigerant. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1953\" data-end=\"2074\"\u003e\n\u003cp data-start=\"1955\" data-end=\"2074\"\u003e\u003cstrong data-start=\"1955\" data-end=\"1989\"\u003eGas\/Suction Distribution Pipe:\u003c\/strong\u003e One line for dividing suction refrigerant. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2075\" data-end=\"2244\"\u003e\n\u003cp data-start=\"2077\" data-end=\"2244\"\u003e\u003cstrong data-start=\"2077\" data-end=\"2093\"\u003eJoint Pipes:\u003c\/strong\u003e Multiple joint adapters (various flare sizes) included — typically 7 joints of 4 types for field adaptation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2245\" data-end=\"2373\"\u003e\n\u003cp data-start=\"2247\" data-end=\"2373\"\u003e\u003cstrong data-start=\"2247\" data-end=\"2263\"\u003ePipe Covers:\u003c\/strong\u003e Insulating foam covers for both pipes to protect and insulate them. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2375\" data-end=\"2403\"\u003e\u003cstrong data-start=\"2378\" data-end=\"2401\"\u003eApprox. Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2404\" data-end=\"2619\"\u003e\n\u003cli data-start=\"2404\" data-end=\"2537\"\u003e\n\u003cp data-start=\"2406\" data-end=\"2537\"\u003eOverall width approx. \u003cstrong data-start=\"2428\" data-end=\"2452\"\u003e17 1\/8 in (≈ 435 mm)\u003c\/strong\u003e (depending on installation configuration). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2538\" data-end=\"2619\"\u003e\n\u003cp data-start=\"2540\" data-end=\"2619\"\u003eApprox. height \u003cstrong data-start=\"2555\" data-end=\"2565\"\u003e6 ⅜ in\u003c\/strong\u003e (≈ 162 mm). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2621\" data-end=\"2772\"\u003e\u003cstrong data-start=\"2624\" data-end=\"2643\"\u003eApprox. Weight:\u003c\/strong\u003e ~1.5 lb (≈ 0.68 kg) (varies slightly depending on included joint pieces and insulation). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2774\" data-end=\"2777\"\u003e\n\u003ch2 data-start=\"2779\" data-end=\"2807\"\u003e Typical Compatibility\u003c\/h2\u003e\n\u003cp data-start=\"2809\" data-end=\"2941\"\u003eThe MSDD-50TR-E is intended for use with medium-to-large split-type outdoor units in Mitsubishi’s line, especially models such as:\u003c\/p\u003e\n\u003cul data-start=\"2942\" data-end=\"3097\"\u003e\n\u003cli data-start=\"2942\" data-end=\"2972\"\u003e\n\u003cp data-start=\"2944\" data-end=\"2972\"\u003e\u003cstrong data-start=\"2944\" data-end=\"2970\"\u003ePUHZ-ZRP71\/100\/125\/140\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2973\" data-end=\"2999\"\u003e\n\u003cp data-start=\"2975\" data-end=\"2999\"\u003e\u003cstrong data-start=\"2975\" data-end=\"2997\"\u003ePUHZ-SHW80\/112\/140\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3000\" data-end=\"3097\"\u003e\n\u003cp data-start=\"3002\" data-end=\"3097\"\u003e\u003cstrong data-start=\"3002\" data-end=\"3023\"\u003ePUHZ-P100\/125\/140\u003c\/strong\u003e\u003cbr data-start=\"3023\" data-end=\"3026\"\u003e(all used in twin 50:50 setups) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3099\" data-end=\"3247\"\u003eThese outdoor units typically use \u003cstrong data-start=\"3133\" data-end=\"3143\"\u003eR-410A\u003c\/strong\u003e refrigerant and support two indoor units connected in parallel.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54744150311203,"sku":"MSDD-50TR-E","price":153.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Mitsubishi_20MSDD-50TR-E_20M-Series_20Branch_20Box_20Distribution_20Pipe.png?v=1771944189","url":"https:\/\/www.acunitsforless.com\/products\/mitsubishi-msdd-50tr-e-m-series-branch-box-distribution-pipe","provider":"acunitsforless.com","version":"1.0","type":"link"}