{"product_id":"mitsubishi-msdd-50br-e-m-series-branch-box-distribution-pipe","title":"Mitsubishi MSDD-50BR-E M-Series Branch Box Distribution Pipe","description":"\u003cp\u003e\u003cstrong\u003eProduct: MSDD-50BR-E\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"157\" data-end=\"592\"\u003eThe \u003cstrong data-start=\"161\" data-end=\"176\"\u003eMSDD-50BR-E\u003c\/strong\u003e is a \u003cstrong data-start=\"182\" data-end=\"214\"\u003ebranch box distribution pipe\u003c\/strong\u003e used in \u003cstrong data-start=\"223\" data-end=\"284\"\u003emulti-zone Mitsubishi mini-split air conditioning systems\u003c\/strong\u003e. It’s a \u003cstrong data-start=\"293\" data-end=\"319\"\u003ebrazed-connection type\u003c\/strong\u003e refrigerant distribution tee that allows the refrigerant from a large outdoor unit to be split into \u003cstrong data-start=\"420\" data-end=\"449\"\u003etwo separate branch boxes\u003c\/strong\u003e, facilitating multi-zone installations with more than one branch box connected to a single outdoor unit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"594\" data-end=\"861\"\u003eThis part is \u003cstrong data-start=\"607\" data-end=\"631\"\u003einstalled by brazing\u003c\/strong\u003e (soldering) into the refrigerant line and is intended for systems where \u003cstrong data-start=\"704\" data-end=\"756\"\u003eflare-type connection distribution (MSDD-50AR-E)\u003c\/strong\u003e is not used or where brazed connections are preferred or required. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"863\" data-end=\"866\"\u003e\n\u003ch3 data-start=\"868\" data-end=\"897\"\u003e\u003cstrong data-start=\"875\" data-end=\"897\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"899\" data-end=\"2503\"\u003e\n\u003cli data-start=\"899\" data-end=\"973\"\u003e\n\u003cp data-start=\"901\" data-end=\"973\"\u003e\u003cstrong data-start=\"901\" data-end=\"917\"\u003ePart Number:\u003c\/strong\u003e \u003cstrong data-start=\"918\" data-end=\"933\"\u003eMSDD-50BR-E\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"974\" data-end=\"1057\"\u003e\n\u003cp data-start=\"976\" data-end=\"1057\"\u003e\u003cstrong data-start=\"976\" data-end=\"993\"\u003eManufacturer:\u003c\/strong\u003e \u003cstrong data-start=\"994\" data-end=\"1017\"\u003eMitsubishi Electric\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1058\" data-end=\"1184\"\u003e\n\u003cp data-start=\"1060\" data-end=\"1184\"\u003e\u003cstrong data-start=\"1060\" data-end=\"1079\"\u003eAccessory Type:\u003c\/strong\u003e Branch box \u003cstrong data-start=\"1091\" data-end=\"1144\"\u003erefrigerant distribution pipe (brazed connection)\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1185\" data-end=\"1376\"\u003e\n\u003cp data-start=\"1187\" data-end=\"1376\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1199\"\u003ePurpose:\u003c\/strong\u003e Splits refrigerant refrigerant lines so that \u003cstrong data-start=\"1245\" data-end=\"1265\"\u003etwo branch boxes\u003c\/strong\u003e can be connected to a single outdoor unit in a multi-zone HVAC system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1377\" data-end=\"1500\"\u003e\n\u003cp data-start=\"1379\" data-end=\"1500\"\u003e\u003cstrong data-start=\"1379\" data-end=\"1399\"\u003eConnection Type:\u003c\/strong\u003e \u003cstrong data-start=\"1400\" data-end=\"1433\"\u003eBrazed connections (soldered)\u003c\/strong\u003e — not flare-type fittings. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1501\" data-end=\"1683\"\u003e\n\u003cp data-start=\"1503\" data-end=\"1683\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1526\"\u003eApplicable Systems:\u003c\/strong\u003e Commonly used with \u003cstrong data-start=\"1546\" data-end=\"1574\"\u003eMXZ-series outdoor units\u003c\/strong\u003e such as MXZ-8A140VA and branch boxes like PAC-AK30BC and PAC-AK50BC. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1684\" data-end=\"1805\"\u003e\n\u003cp data-start=\"1686\" data-end=\"1805\"\u003e\u003cstrong data-start=\"1686\" data-end=\"1702\"\u003eRefrigerant:\u003c\/strong\u003e Typically \u003cstrong data-start=\"1713\" data-end=\"1723\"\u003eR-410A\u003c\/strong\u003e (standard refrigerant for these systems). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1806\" data-end=\"1928\"\u003e\n\u003cp data-start=\"1808\" data-end=\"1928\"\u003e\u003cstrong data-start=\"1808\" data-end=\"1829\"\u003eLiquid Line Size:\u003c\/strong\u003e \u003cstrong data-start=\"1830\" data-end=\"1854\"\u003e3\/8 inch (Ø 9.52 mm)\u003c\/strong\u003e for inlet and branch connections. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"2059\"\u003e\n\u003cp data-start=\"1931\" data-end=\"2059\"\u003e\u003cstrong data-start=\"1931\" data-end=\"1957\"\u003eSuction\/Gas Line Size:\u003c\/strong\u003e \u003cstrong data-start=\"1958\" data-end=\"1983\"\u003e5\/8 inch (Ø 15.88 mm)\u003c\/strong\u003e for inlet and branch connections. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2324\"\u003e\n\u003cp data-start=\"2062\" data-end=\"2079\"\u003e\u003cstrong data-start=\"2062\" data-end=\"2077\"\u003eDimensions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2082\" data-end=\"2324\"\u003e\n\u003cli data-start=\"2082\" data-end=\"2203\"\u003e\n\u003cp data-start=\"2084\" data-end=\"2203\"\u003e\u003cstrong data-start=\"2084\" data-end=\"2108\"\u003eLiquid pipe lengths:\u003c\/strong\u003e ~100 mm (to outdoor unit) and ~80 mm (to branch box) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2206\" data-end=\"2324\"\u003e\n\u003cp data-start=\"2208\" data-end=\"2324\"\u003e\u003cstrong data-start=\"2208\" data-end=\"2229\"\u003eGas pipe lengths:\u003c\/strong\u003e ~150 mm (to outdoor unit) and ~80 mm (to branch box) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2325\" data-end=\"2503\"\u003e\n\u003cp data-start=\"2327\" data-end=\"2503\"\u003e\u003cstrong data-start=\"2327\" data-end=\"2344\"\u003eInstallation:\u003c\/strong\u003e Requires brazing to the refrigerant piping; heat-insulation covers are typically installed afterward (provided\/added). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2505\" data-end=\"2508\"\u003e\n\u003ch3 data-start=\"2510\" data-end=\"2535\"\u003e\u003cstrong data-start=\"2518\" data-end=\"2535\"\u003eUsage \u0026amp; Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2537\" data-end=\"3432\"\u003e\n\u003cli data-start=\"2537\" data-end=\"2747\"\u003e\n\u003cp data-start=\"2539\" data-end=\"2747\"\u003e\u003cstrong data-start=\"2539\" data-end=\"2551\"\u003ePurpose:\u003c\/strong\u003e Allows \u003cstrong data-start=\"2559\" data-end=\"2579\"\u003etwo branch boxes\u003c\/strong\u003e to be connected from one outdoor unit in a \u003cstrong data-start=\"2623\" data-end=\"2637\"\u003emulti-zone\u003c\/strong\u003e setup, splitting both \u003cstrong data-start=\"2660\" data-end=\"2704\"\u003eliquid and suction\/gas refrigerant lines\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2748\" data-end=\"3005\"\u003e\n\u003cp data-start=\"2750\" data-end=\"3005\"\u003e\u003cstrong data-start=\"2750\" data-end=\"2774\"\u003eInstallation Method:\u003c\/strong\u003e \u003cstrong data-start=\"2775\" data-end=\"2796\"\u003eBrazed connection\u003c\/strong\u003e — refrigerant pipes are soldered to this distribution tee during installation, which provides a permanent, leak-free joint suitable for larger or fixed installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3006\" data-end=\"3201\"\u003e\n\u003cp data-start=\"3008\" data-end=\"3201\"\u003e\u003cstrong data-start=\"3008\" data-end=\"3031\"\u003eComplementary Part:\u003c\/strong\u003e The \u003cstrong data-start=\"3036\" data-end=\"3051\"\u003eMSDD-50AR-E\u003c\/strong\u003e is the \u003cstrong data-start=\"3059\" data-end=\"3087\"\u003eflare-connection version\u003c\/strong\u003e of this distribution pipe, used when brazing isn’t desired or feasible. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3202\" data-end=\"3432\"\u003e\n\u003cp data-start=\"3204\" data-end=\"3432\"\u003e\u003cstrong data-start=\"3204\" data-end=\"3229\"\u003eTypical Applications:\u003c\/strong\u003e Systems with \u003cstrong data-start=\"3243\" data-end=\"3286\"\u003elarge outdoor units (e.g., MXZ-8A140VA)\u003c\/strong\u003e and multiple branch boxes (e.g., PAC-AK30BC, PAC-AK50BC) requiring a split refrigerant distribution path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54744117149987,"sku":"MSDD-50BR-E","price":101.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/mitsubishi-msdd-50br-e-m-series-branch-box-distribution-pipe.png?v=1771943604","url":"https:\/\/www.acunitsforless.com\/products\/mitsubishi-msdd-50br-e-m-series-branch-box-distribution-pipe","provider":"acunitsforless.com","version":"1.0","type":"link"}