{"product_id":"mitsubishi-msdd-50ar-e-m-series-branch-box-distribution-pipe","title":"Mitsubishi MSDD-50AR-E M-Series Branch Box Distribution Pipe","description":"\u003cp\u003e\u003cstrong\u003eProduct: MSDD-50AR-E\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"189\" data-end=\"566\"\u003eThe \u003cstrong data-start=\"193\" data-end=\"208\"\u003eMSDD-50AR-E\u003c\/strong\u003e is a \u003cstrong data-start=\"214\" data-end=\"239\"\u003edistribution pipe set\u003c\/strong\u003e used in \u003cstrong data-start=\"248\" data-end=\"306\"\u003eMitsubishi Electric multi-zone mini-split HVAC systems\u003c\/strong\u003e to \u003cstrong data-start=\"310\" data-end=\"337\"\u003esplit refrigerant lines\u003c\/strong\u003e when installing \u003cstrong data-start=\"354\" data-end=\"374\"\u003etwo branch boxes\u003c\/strong\u003e off a larger outdoor condenser. It provides \u003cstrong data-start=\"419\" data-end=\"445\"\u003eflare-type connections\u003c\/strong\u003e for both the liquid and suction lines, making installation easier without brazing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"568\" data-end=\"791\"\u003eThis accessory is typically used with larger \u003cstrong data-start=\"613\" data-end=\"641\"\u003eMXZ series outdoor units\u003c\/strong\u003e and appropriate branch boxes to enable refrigerant distribution to multiple indoor units in a multi-zone setup. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"798\" data-end=\"822\"\u003e Key Specifications\u003c\/h2\u003e\n\u003cp data-start=\"824\" data-end=\"890\"\u003e\u003cstrong data-start=\"824\" data-end=\"840\"\u003ePart Number:\u003c\/strong\u003e MSDD-50AR-E \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"892\" data-end=\"1005\"\u003e\u003cstrong data-start=\"892\" data-end=\"911\"\u003eAccessory Type:\u003c\/strong\u003e Branch Box \u003cstrong data-start=\"923\" data-end=\"948\"\u003eDistribution Pipe Set\u003c\/strong\u003e (flare connection) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1007\" data-end=\"1034\"\u003e\u003cstrong data-start=\"1007\" data-end=\"1032\"\u003eSystem Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1035\" data-end=\"1210\"\u003e\n\u003cli data-start=\"1035\" data-end=\"1210\"\u003e\n\u003cp data-start=\"1037\" data-end=\"1210\"\u003eUsed in \u003cstrong data-start=\"1045\" data-end=\"1078\"\u003emulti-zone mini-split systems\u003c\/strong\u003e with two branch boxes (e.g., in systems with larger outdoor units such as the \u003cem data-start=\"1157\" data-end=\"1170\"\u003eMXZ-8A140VA\u003c\/em\u003e). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1212\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1212\" data-end=\"1233\"\u003eRefrigerant Type:\u003c\/strong\u003e R-410A (typical system refrigerant) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1309\" data-end=\"1335\"\u003e\u003cstrong data-start=\"1309\" data-end=\"1333\"\u003eConnections \u0026amp; Sizes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1336\" data-end=\"1508\"\u003e\n\u003cli data-start=\"1336\" data-end=\"1420\"\u003e\n\u003cp data-start=\"1338\" data-end=\"1420\"\u003e\u003cstrong data-start=\"1338\" data-end=\"1365\"\u003eLiquid line connection:\u003c\/strong\u003e 3\/8 inch flare \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1421\" data-end=\"1508\"\u003e\n\u003cp data-start=\"1423\" data-end=\"1508\"\u003e\u003cstrong data-start=\"1423\" data-end=\"1455\"\u003eSuction\/gas line connection:\u003c\/strong\u003e 5\/8 inch flare \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1510\" data-end=\"1606\"\u003e\u003cstrong data-start=\"1510\" data-end=\"1530\"\u003eConnection Type:\u003c\/strong\u003e Flared fittings (no brazing required) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1608\" data-end=\"1634\"\u003e\u003cstrong data-start=\"1608\" data-end=\"1632\"\u003eIncluded Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1635\" data-end=\"1883\"\u003e\n\u003cli data-start=\"1635\" data-end=\"1716\"\u003e\n\u003cp data-start=\"1637\" data-end=\"1716\"\u003e1 × \u003cstrong data-start=\"1641\" data-end=\"1669\"\u003eLiquid distribution pipe\u003c\/strong\u003e (3\/8″) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1717\" data-end=\"1797\"\u003e\n\u003cp data-start=\"1719\" data-end=\"1797\"\u003e1 × \u003cstrong data-start=\"1723\" data-end=\"1748\"\u003eGas distribution pipe\u003c\/strong\u003e (5\/8″) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1883\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1883\"\u003e2 × \u003cstrong data-start=\"1804\" data-end=\"1830\"\u003eHeat insulation covers\u003c\/strong\u003e (for piping) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1885\" data-end=\"1956\"\u003e\u003cstrong data-start=\"1885\" data-end=\"1896\"\u003eWeight:\u003c\/strong\u003e ~1.5 lb (≈ 0.68 kg) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1958\" data-end=\"2076\"\u003e\u003cstrong data-start=\"1958\" data-end=\"1982\"\u003eDimensions (approx):\u003c\/strong\u003e ~7 ⅜ inches wide \u003cem data-start=\"2000\" data-end=\"2036\"\u003e(varies by pipe length and layout)\u003c\/em\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2078\" data-end=\"2193\"\u003e\u003cstrong data-start=\"2078\" data-end=\"2091\"\u003eWarranty:\u003c\/strong\u003e Around \u003cstrong data-start=\"2099\" data-end=\"2125\"\u003e90 days parts warranty\u003c\/strong\u003e (varies by retailer\/region) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54744094376227,"sku":"MSDD-50AR-E","price":173.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/mitsubishi-msdd-50ar-e-m-series-branch-box-distribution-pipe.png?v=1771943394","url":"https:\/\/www.acunitsforless.com\/products\/mitsubishi-msdd-50ar-e-m-series-branch-box-distribution-pipe","provider":"acunitsforless.com","version":"1.0","type":"link"}