{"product_id":"mitsubishi-cmy-y62-g-e-city-multi®-2-branch-joint","title":"Mitsubishi CMY-Y62-G-E - City Multi® 2-Branch Joint","description":"\u003cp\u003e\u003cstrong\u003eProduct: CMY-Y62-G-E\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"309\" data-end=\"911\"\u003eThe \u003cstrong data-start=\"313\" data-end=\"329\"\u003eCMY‑Y62‑GA‑E\u003c\/strong\u003e is a \u003cstrong data-start=\"335\" data-end=\"393\"\u003etwo‑way refrigerant branch joint\/distribution pipe kit\u003c\/strong\u003e designed for \u003cstrong data-start=\"407\" data-end=\"450\"\u003emulti‑zone VRF\/City Multi outdoor units\u003c\/strong\u003e (such as the \u003cem data-start=\"464\" data-end=\"479\"\u003ePUMY‑P250\/300\u003c\/em\u003e and similar PUMY\/P‑series models). It serves as a \u003cstrong data-start=\"530\" data-end=\"563\"\u003erefrigerant line branch joint\u003c\/strong\u003e that splits the outdoor refrigerant piping into two outlets — one for each downstream branch of system piping — which then connects to indoor units or branch boxes. This type of joint is part of the \u003cstrong data-start=\"763\" data-end=\"799\"\u003erefrigerant distribution network\u003c\/strong\u003e and facilitates complex piping layouts in larger commercial HVAC systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"913\" data-end=\"916\"\u003e\n\u003ch2 data-start=\"918\" data-end=\"946\"\u003e\u003cstrong data-start=\"924\" data-end=\"946\"\u003eKey Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"948\" data-end=\"966\"\u003e\u003cstrong data-start=\"948\" data-end=\"964\"\u003ePart Number:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"967\" data-end=\"1079\"\u003e\n\u003cli data-start=\"967\" data-end=\"1079\"\u003e\n\u003cp data-start=\"969\" data-end=\"1079\"\u003e\u003cstrong data-start=\"969\" data-end=\"985\"\u003eCMY‑Y62‑GA‑E\u003c\/strong\u003e (sometimes referenced as CMY‑Y62‑G‑E in documentation). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1081\" data-end=\"1102\"\u003e\u003cstrong data-start=\"1081\" data-end=\"1100\"\u003eAccessory Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1103\" data-end=\"1198\"\u003e\n\u003cli data-start=\"1103\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1105\" data-end=\"1198\"\u003e\u003cstrong data-start=\"1105\" data-end=\"1159\"\u003e2‑way Refrigerant Branch Joint \/ Distribution Pipe\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1200\" data-end=\"1218\"\u003e\u003cstrong data-start=\"1200\" data-end=\"1216\"\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1219\" data-end=\"1494\"\u003e\n\u003cli data-start=\"1219\" data-end=\"1494\"\u003e\n\u003cp data-start=\"1221\" data-end=\"1494\"\u003eUsed in \u003cstrong data-start=\"1229\" data-end=\"1283\"\u003eMitsubishi Electric CITY MULTI \/ VRF outdoor units\u003c\/strong\u003e — typically larger \u003cem data-start=\"1303\" data-end=\"1309\"\u003ePUMY\u003c\/em\u003e series heat pump or cooling‑only units — where refrigerant piping must be \u003cstrong data-start=\"1384\" data-end=\"1422\"\u003ebranched into two downstream lines\u003c\/strong\u003e for indoor units or branch boxes. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1496\" data-end=\"1511\"\u003e\u003cstrong data-start=\"1496\" data-end=\"1509\"\u003eFunction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1512\" data-end=\"1691\"\u003e\n\u003cli data-start=\"1512\" data-end=\"1691\"\u003e\n\u003cp data-start=\"1514\" data-end=\"1691\"\u003eSplits the refrigerant refrigerant line (both liquid and gas pipes) into \u003cstrong data-start=\"1587\" data-end=\"1611\"\u003etwo separate outlets\u003c\/strong\u003e to feed different branches of the system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1693\" data-end=\"1718\"\u003e\u003cstrong data-start=\"1693\" data-end=\"1716\"\u003ePipe Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1719\" data-end=\"1838\"\u003e\n\u003cli data-start=\"1719\" data-end=\"1838\"\u003e\n\u003cp data-start=\"1721\" data-end=\"1838\"\u003eTwo \u003cstrong data-start=\"1725\" data-end=\"1734\"\u003eports\u003c\/strong\u003e (one for each branch) on both \u003cstrong data-start=\"1765\" data-end=\"1799\"\u003eliquid and suction (gas) sides\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1840\" data-end=\"1855\"\u003e\u003cstrong data-start=\"1840\" data-end=\"1853\"\u003eMaterial:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1856\" data-end=\"1985\"\u003e\n\u003cli data-start=\"1856\" data-end=\"1985\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1985\"\u003e\u003cstrong data-start=\"1858\" data-end=\"1902\"\u003ePhosphorus‑deoxidized copper (C1220T‑OL)\u003c\/strong\u003e — standard HVAC refrigerant piping material. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1987\" data-end=\"2004\"\u003e\u003cstrong data-start=\"1987\" data-end=\"2002\"\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2005\" data-end=\"2137\"\u003e\n\u003cli data-start=\"2005\" data-end=\"2137\"\u003e\n\u003cp data-start=\"2007\" data-end=\"2137\"\u003eTypically includes \u003cstrong data-start=\"2026\" data-end=\"2047\"\u003einsulation covers\u003c\/strong\u003e for the liquid and gas pipes (foamed polyethylene). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2139\" data-end=\"2167\"\u003e\u003cstrong data-start=\"2139\" data-end=\"2165\"\u003eReducers\/Reducers Kit:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2168\" data-end=\"2376\"\u003e\n\u003cli data-start=\"2168\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2170\" data-end=\"2376\"\u003eOften supplied with a set of reducers\/fittings of various sizes so different refrigerant pipe diameters (e.g., 3\/8″, 1\/2″, 5\/8″, etc.) can be connected without welding. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2378\" data-end=\"2401\"\u003e\u003cstrong data-start=\"2378\" data-end=\"2399\"\u003eConnection Style:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2402\" data-end=\"2605\"\u003e\n\u003cli data-start=\"2402\" data-end=\"2605\"\u003e\n\u003cp data-start=\"2404\" data-end=\"2605\"\u003eNormally designed for \u003cstrong data-start=\"2426\" data-end=\"2447\"\u003ebrazed connection\u003c\/strong\u003e to the piping network (though reducers\/adapters allow for flare or brazed joining depending on installation practices). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2607\" data-end=\"2638\"\u003e\u003cstrong data-start=\"2607\" data-end=\"2636\"\u003eCompatible Outdoor Units:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2639\" data-end=\"2882\"\u003e\n\u003cli data-start=\"2639\" data-end=\"2882\"\u003e\n\u003cp data-start=\"2641\" data-end=\"2882\"\u003ePUMY‑P\/‑SP\/‑HP series (including larger cooling‑only and heat pump models like PUMY‑P250, PUMY‑P300) and other City Multi \u003cem data-start=\"2763\" data-end=\"2773\"\u003eS‑Series\u003c\/em\u003e or similar VRF outdoor units that support multiple downstream lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":54744331878691,"sku":"CMY-Y62-GA-E","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/CMY.png?v=1771356137","url":"https:\/\/www.acunitsforless.com\/products\/mitsubishi-cmy-y62-g-e-city-multi%c2%ae-2-branch-joint","provider":"acunitsforless.com","version":"1.0","type":"link"}