{"product_id":"goodman-wire-harness-economizer-0259g00214","title":"Goodman Wire Harness Economizer 0259G00214","description":"\u003cp\u003eGoodman Wire Harness Economizer \u003cspan\u003e0259G00214\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe DP14GM24 – 48 and A\/GPG1424 – 48 units have single-stage compressors and use a PCBAG123 single-stage control board. Part # 0259G00214 (economizer wiring harness) would be used to connect from the control board and thermostat to the economizer 9-pin connector (see instructions below). Part # 0259L00412 would be used for gas\/electric package units with a two-stage compressor (14 SEER 5 Ton and 16 SEER units).\u003c\/p\u003e\n\u003cp\u003eTo connect an economizer to an “H” or “M” series package cooling unit with a single-stage compressor, use Part # 0259G00213. For single-stage package heat pump models, Part # 0259G00215 would be used to connect from the control board and thermostat to the economizer 9-pin connector (see instructions below). Part # 0259L00411 would be used for heat pump package units with a two-stage compressor (14 SEER 5 Ton and 16 SEER units).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGas Package Units – 1-stage cooling (Wire harness Part # 0259G00214):\u003c\/strong\u003e\u003cbr\u003e1. Connect yellow wire from harness pin #2 to the Y connection (yellow wire) from thermostat.\u003cbr\u003e2. Connect yellow wire from harness pin #4 to the Y\/Y2 connection on the unit (yellow wire).\u003cbr\u003e3. Connect blue wire from harness pin #5 to 24V Common (blue common wire) on unit.\u003cbr\u003e4. Connect green wire from harness pin #6 to ECON spade on control board.\u003cbr\u003e5. Connect red wire from harness pin #9 to R terminal (red wire) on transformer.\u003c\/p\u003e\n\u003cp data-wp-editing=\"1\"\u003e\u003cimg data-recalc-dims=\"1\" decoding=\"async\" class=\"aligncenter wp-image-3777 size-full entered lazyloaded\" src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-1.jpg?resize=700%2C249\u0026amp;ssl=1\" alt=\"Economizer Installation Wiring for Gas Package Units – 1-stage cooling\" width=\"700\" height=\"249\" data-lazy-srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-1.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-1.jpg?resize=300%2C107\u0026amp;ssl=1 300w\" data-lazy-sizes=\"(max-width: 700px) 100vw, 700px\" data-lazy-src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-1.jpg?resize=700%2C249\u0026amp;ssl=1\" data-ll-status=\"loaded\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-1.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-1.jpg?resize=300%2C107\u0026amp;ssl=1 300w\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGas Package Units – 2-stage cooling (Wire harness Part # 0259L00412):\u003c\/strong\u003e\u003cbr\u003e1. Connect yellow wire from harness pin #1 to the Y1 connection from thermostat.\u003cbr\u003e2. Connect yellow wire from harness pin #4 to the Y1 unit control board connection.\u003cbr\u003e3. Connect purple wire from harness pin #2 to the Y2 connection from thermostat.\u003cbr\u003e4. Connect purple wire from harness pin #3 to the Y2 unit control board connection.\u003cbr\u003e5. Connect blue wire from harness pin #5 to 24V Common (blue common wire) on unit.\u003cbr\u003e6. Connect green wire from harness pin #6 to ECON spade on control board.\u003cbr\u003e7. Connect red wire from harness pin #9 to R terminal or S2 terminal (if present) on control board.\u003c\/p\u003e\n\u003cp\u003e\u003cimg data-recalc-dims=\"1\" decoding=\"async\" class=\"aligncenter wp-image-3776 size-full entered lazyloaded\" src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-2.jpg?resize=700%2C342\u0026amp;ssl=1\" alt=\"Economizer Installation Wiring for Gas Package Units – 2-stage cooling\" width=\"700\" height=\"342\" data-lazy-srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-2.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-2.jpg?resize=300%2C147\u0026amp;ssl=1 300w\" data-lazy-sizes=\"(max-width: 700px) 100vw, 700px\" data-lazy-src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-2.jpg?resize=700%2C342\u0026amp;ssl=1\" data-ll-status=\"loaded\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-2.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-2.jpg?resize=300%2C147\u0026amp;ssl=1 300w\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling Package Units – 1-stage (Wire harness Part # 0259G00213):\u003c\/strong\u003e\u003cbr\u003e1. Connect yellow wire from harness pin #2 to the Y connection from thermostat.\u003cbr\u003e2. Connect yellow wire from harness pin #4 to Y connection (yellow wire) on unit.\u003cbr\u003e3. Connect blue wire from harness pin #5 to 24V Common connection (blue wires) on LVTB (low voltage terminal block) or C for unit and thermostat.\u003cbr\u003e4. Connect green wire from harness pin #6 to G connection (green wire) for unit and thermostat.\u003cbr\u003e5. Connect red wire from harness pin #9 to R connection (red wire) for unit and thermostat.\u003c\/p\u003e\n\u003cp\u003e\u003cimg data-recalc-dims=\"1\" decoding=\"async\" class=\"aligncenter wp-image-3676 size-full entered lazyloaded\" src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-3.jpg?resize=700%2C367\" alt=\"Gas Package Units wiring instalation\" width=\"700\" height=\"367\" data-lazy-srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-3.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-3.jpg?resize=300%2C157\u0026amp;ssl=1 300w\" data-lazy-sizes=\"(max-width: 700px) 100vw, 700px\" data-lazy-src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-3.jpg?resize=700%2C367\" data-ll-status=\"loaded\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-3.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-3.jpg?resize=300%2C157\u0026amp;ssl=1 300w\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Pump Package Units – 1-stage (Wire harness Part # 0259G00215):\u003c\/strong\u003e\u003cbr\u003e1. Connect yellow wire from harness pin #2 to the Y connection from thermostat.\u003cbr\u003e2. Connect yellow wire from harness pin #4 to Y connection on unit.\u003cbr\u003e3. Connect blue wire from harness pin #5 to 24V Common connection (blue wires) on LVTB (low voltage terminal block) or C for unit and thermostat.\u003cbr\u003e4. Connect green wire from harness pin #6 to G connection (green wire) for unit and thermostat.\u003cbr\u003e5. Connect orange wire from harness pin #8 to O connection (orange wire) for unit and thermostat.\u003cbr\u003e6. Connect red wire from harness pin #9 to R connection (red wire) for unit and thermostat.\u003c\/p\u003e\n\u003cp data-wp-editing=\"1\"\u003e\u003cimg data-recalc-dims=\"1\" decoding=\"async\" class=\"aligncenter wp-image-3778 size-full entered lazyloaded\" src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-4.jpg?resize=700%2C245\u0026amp;ssl=1\" alt=\"Heat Pump Package Units wiring instalation\" width=\"700\" height=\"245\" data-lazy-srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-4.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-4.jpg?resize=300%2C105\u0026amp;ssl=1 300w\" data-lazy-sizes=\"(max-width: 700px) 100vw, 700px\" data-lazy-src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-4.jpg?resize=700%2C245\u0026amp;ssl=1\" data-ll-status=\"loaded\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-4.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2016\/11\/sp-038-rev-4.jpg?resize=300%2C105\u0026amp;ssl=1 300w\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Pump Package Units – 2-stage (Wire harness Part # 0259L00411):\u003c\/strong\u003e\u003cbr\u003e1. Connect yellow wire from harness pin #1 to the Y1 connection from thermostat.\u003cbr\u003e2. Connect yellow wire from harness pin #4 to the Y1 connection (purple wire) on unit.\u003cbr\u003e3. Connect purple wire from harness pin #2 to the Y2 connection from thermostat.\u003cbr\u003e4. Connect purple wire from harness pin #3 to the Y2 connection (yellow wire) on unit.\u003cbr\u003e5. Connect blue wire from harness pin #5 to 24V Common connection (blue wire) for unit and thermostat.\u003cbr\u003e6. Connect green wire from harness pin #6 to G connection (green wire) for unit and thermostat.\u003cbr\u003e7. Connect orange wire from harness pin #8 to O connection (orange wire) for unit and thermostat.\u003cbr\u003e8. Connect red wire from harness pin #9 to R connection (red wire) for unit and thermostat.\u003c\/p\u003e\n\u003cp\u003e\u003cimg data-recalc-dims=\"1\" decoding=\"async\" class=\"aligncenter wp-image-3458 size-full entered lazyloaded\" src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-5.jpg?resize=700%2C242\u0026amp;ssl=1\" alt=\"Heat Pump Package Units wiring instalation\" width=\"700\" height=\"242\" data-lazy-srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-5.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-5.jpg?resize=300%2C104\u0026amp;ssl=1 300w\" data-lazy-sizes=\"(max-width: 700px) 100vw, 700px\" data-lazy-src=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-5.jpg?resize=700%2C242\u0026amp;ssl=1\" data-ll-status=\"loaded\" sizes=\"(max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-5.jpg?w=700\u0026amp;ssl=1 700w, https:\/\/i0.wp.com\/hvacdist.com\/wp-content\/uploads\/2018\/12\/sp-038-rev-5.jpg?resize=300%2C104\u0026amp;ssl=1 300w\"\u003e\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":55068547416355,"sku":"0259G00214","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/IMG-0259G00214.jpg?v=1778382358","url":"https:\/\/www.acunitsforless.com\/products\/goodman-wire-harness-economizer-0259g00214","provider":"acunitsforless.com","version":"1.0","type":"link"}