{"product_id":"goodman-dfke-02-downflow-kit","title":"Goodman DFKE-02 Downflow Kit","description":"\u003cp\u003e\u003cstrong\u003eProduct: DFKE-02\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescriptions\u003c\/strong\u003eThe \u003cstrong data-start=\"158\" data-end=\"169\"\u003eDFKE-02\u003c\/strong\u003e is a \u003cstrong data-start=\"175\" data-end=\"191\"\u003edownflow kit\u003c\/strong\u003e accessory for Goodman (and related Daikin\/AMST\/AMVT) \u003cstrong data-start=\"245\" data-end=\"261\"\u003eair handlers\u003c\/strong\u003e. It’s designed to be installed on the \u003cstrong data-start=\"300\" data-end=\"341\"\u003ebottom of the air handler’s drain pan\u003c\/strong\u003e when the unit is set up in a \u003cstrong data-start=\"371\" data-end=\"395\"\u003edownflow orientation\u003c\/strong\u003e (i.e., conditioned air and condensate flow downward). Its purpose is to \u003cstrong data-start=\"468\" data-end=\"531\"\u003eprevent unwanted condensation (“sweating”) on the drain pan\u003c\/strong\u003e surfaces, which can occur in downflow installations and could otherwise lead to moisture buildup, corrosion, or water damage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003chr data-start=\"697\" data-end=\"700\"\u003e\n\u003ch2 data-start=\"702\" data-end=\"740\"\u003e\u003cstrong data-start=\"708\" data-end=\"740\"\u003eDescription \u0026amp; Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"742\" data-end=\"757\"\u003e\u003cstrong data-start=\"746\" data-end=\"757\"\u003eGeneral\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"758\" data-end=\"1029\"\u003e\n\u003cli data-start=\"758\" data-end=\"807\"\u003e\n\u003cp data-start=\"760\" data-end=\"807\"\u003e\u003cstrong data-start=\"760\" data-end=\"772\"\u003eProduct:\u003c\/strong\u003e Goodman \u003cstrong data-start=\"781\" data-end=\"805\"\u003eDFKE-02 Downflow Kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"808\" data-end=\"877\"\u003e\n\u003cp data-start=\"810\" data-end=\"877\"\u003e\u003cstrong data-start=\"810\" data-end=\"819\"\u003eType:\u003c\/strong\u003e Drain pan accessory \/ downflow condensation control kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"1029\"\u003e\n\u003cp data-start=\"880\" data-end=\"1029\"\u003e\u003cstrong data-start=\"880\" data-end=\"896\"\u003eApplication:\u003c\/strong\u003e Used with \u003cstrong data-start=\"907\" data-end=\"945\"\u003edownflow air handler installations\u003c\/strong\u003e to manage condensate and reduce pan sweating. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1031\" data-end=\"1052\"\u003e\u003cstrong data-start=\"1035\" data-end=\"1052\"\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1053\" data-end=\"1403\"\u003e\n\u003cli data-start=\"1053\" data-end=\"1177\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1177\"\u003eDesigned for use with Goodman \u003cstrong data-start=\"1085\" data-end=\"1122\"\u003eAMST and AMVT series air handlers\u003c\/strong\u003e — particularly those rated \u003cstrong data-start=\"1150\" data-end=\"1165\"\u003e2 – 3.5 ton\u003c\/strong\u003e capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-start=\"1405\" data-end=\"1618\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1618\"\u003e\u003cstrong data-start=\"1407\" data-end=\"1432\"\u003eDownflow Kit Context:\u003c\/strong\u003e Goodman manuals list \u003cstrong data-start=\"1454\" data-end=\"1465\"\u003eDFKE-02\u003c\/strong\u003e as the required downflow configuration kit in humid environments for AMST\/AMVT units to prevent coil pan sweating. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr data-start=\"1620\" data-end=\"1623\"\u003e\n\u003ch3 data-start=\"1625\" data-end=\"1655\"\u003e\u003cstrong data-start=\"1629\" data-end=\"1655\"\u003ePerformance \/ Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1656\" data-end=\"2041\"\u003e\n\u003cli data-start=\"1656\" data-end=\"1707\"\u003e\n\u003cp data-start=\"1658\" data-end=\"1707\"\u003e\u003cstrong data-start=\"1658\" data-end=\"1674\"\u003eOrientation:\u003c\/strong\u003e \u003cstrong data-start=\"1675\" data-end=\"1700\"\u003eDownflow installation\u003c\/strong\u003e only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1871\"\u003e\n\u003cp data-start=\"1710\" data-end=\"1725\"\u003e\u003cstrong data-start=\"1710\" data-end=\"1723\"\u003eFunction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1728\" data-end=\"1871\"\u003e\n\u003cli data-start=\"1728\" data-end=\"1804\"\u003e\n\u003cp data-start=\"1730\" data-end=\"1804\"\u003eApplied to the bottom of the drain pan to \u003cstrong data-start=\"1772\" data-end=\"1804\"\u003eprevent condensation buildup\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1807\" data-end=\"1871\"\u003e\n\u003cp data-start=\"1809\" data-end=\"1871\"\u003eHelps condense moisture to flow properly to the drain outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1872\" data-end=\"2041\"\u003e\n\u003cp data-start=\"1874\" data-end=\"2041\"\u003e\u003cstrong data-start=\"1874\" data-end=\"1891\"\u003eInstallation:\u003c\/strong\u003e Typically installed by a qualified HVAC technician as part of the air handler setup (sold as an accessory part) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2043\" data-end=\"2046\"\u003e\n\u003ch3 data-start=\"2048\" data-end=\"2073\"\u003e\u003cstrong data-start=\"2052\" data-end=\"2073\"\u003ePhysical \u0026amp; Weight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2074\" data-end=\"2297\"\u003e\n\u003cli data-start=\"2074\" data-end=\"2194\"\u003e\n\u003cp data-start=\"2076\" data-end=\"2194\"\u003e\u003cstrong data-start=\"2076\" data-end=\"2095\"\u003eProduct Weight:\u003c\/strong\u003e Approximately \u003cstrong data-start=\"2110\" data-end=\"2129\"\u003e10 lb (≈4.5 kg)\u003c\/strong\u003e (total accessory weight) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2195\" data-end=\"2297\"\u003e\n\u003cp data-start=\"2197\" data-end=\"2297\"\u003e\u003cstrong data-start=\"2197\" data-end=\"2217\"\u003eShipping Weight:\u003c\/strong\u003e ~15 lb (≈6.8 kg) (depending on packaging)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":54762030825763,"sku":"DFKE-02","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/IMG-DFK-B.jpg?v=1771589611","url":"https:\/\/www.acunitsforless.com\/products\/goodman-dfke-02-downflow-kit","provider":"acunitsforless.com","version":"1.0","type":"link"}