{"product_id":"goodman-5-ton-r32-air-handler-amvt60dp1300","title":"Goodman 5 Ton R-32 Variable-Speed Air Handler AMVT60DP1300","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman AMVT60DP1300\u003c\/strong\u003e is a 5 ton, R-32 multi-position air handler with a variable-speed ECM blower, factory-installed TXV, and a factory-installed R-32 refrigerant detection sensor. It is the AHRI-matched indoor unit for Goodman's GLZT7 two-stage heat pumps in 4 and 5 ton sizes, and it replaces the R-410A AMVT60DP1400.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-speed ECM blower\u003c\/strong\u003e holds steady airflow across a wide range of duct static pressures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunicating-capable:\u003c\/strong\u003e works with Goodman communicating equipment and thermostats and auto-configures airflow in communicating mode. It also runs on standard 24V controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-installed TXV\u003c\/strong\u003e for cooling and heat pump operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory-installed R-32 refrigerant detection sensor\u003c\/strong\u003e, as required for A2L refrigerant systems.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAll-aluminum evaporator coil.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-position:\u003c\/strong\u003e upflow, downflow, horizontal left or right.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTight cabinet:\u003c\/strong\u003e less than 2.0% air leakage at 1.0 in. w.c. (ASHRAE 193), with foil-faced insulation and a thermoplastic drain pan with secondary drain connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService-friendly:\u003c\/strong\u003e tool-less filter access, CFM indicator, and recall of the last six fault codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric heat ready:\u003c\/strong\u003e accepts Goodman HKTS field-installed heat kits from 3 to 25 kW.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAMVT60DP1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM, 1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum airflow\u003c\/td\u003e\n\u003ctd\u003eApprox. 2,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering device\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil\u003c\/td\u003e\n\u003ctd\u003eAll-aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant connections\u003c\/td\u003e\n\u003ctd\u003e3\/8\" liquid, 3\/4\" suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e24.5\" x 21\" x 58\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 172 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric heat\u003c\/td\u003e\n\u003ctd\u003eGoodman HKTS kits, 3 to 25 kW (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces\u003c\/td\u003e\n\u003ctd\u003eAMVT60DP1400 (R-410A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAHRI-matched heat pump systems\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOutdoor unit\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLZT7CA4810 (4 ton)\u003c\/td\u003e\n\u003ctd\u003eTwo-stage heat pump\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLZT7CA6010 (5 ton)\u003c\/td\u003e\n\u003ctd\u003eTwo-stage heat pump\u003c\/td\u003e\n\u003ctd\u003e16.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657368\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAlways confirm the exact outdoor unit and air handler combination in the AHRI directory before ordering.\u003c\/p\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with R-32 equipment only. Do not pair with R-410A or R-22 outdoor units.\u003c\/li\u003e\n\u003cli\u003eInstall to the manufacturer's instructions and local code, including A2L refrigerant requirements.\u003c\/li\u003e\n\u003cli\u003eSize the heat kit and branch circuit to the home's heat loss and the installation manual.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect the unit for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCan I use this with a 4 ton outdoor unit?\u003c\/h3\u003e\n\u003cp\u003eYes, if the combination is AHRI certified. The GLZT7CA4810 4 ton two-stage heat pump is certified with this air handler. The outdoor unit should never be larger than the air handler.\u003c\/p\u003e\n\u003ch3\u003eDoes it need a communicating thermostat?\u003c\/h3\u003e\n\u003cp\u003eNo. It works with standard 24V thermostats. Communicating mode with compatible Goodman equipment adds automatic airflow setup and fault reporting.\u003c\/p\u003e\n\u003ch3\u003eIs a heat kit included?\u003c\/h3\u003e\n\u003cp\u003eNo. Heat kits are sold separately. Choose an HKTS kit sized for the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eWill it work with my existing R-410A condenser?\u003c\/h3\u003e\n\u003cp\u003eNo. This is an R-32 air handler. It must be paired with a matched R-32 outdoor unit.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":55906135376163,"sku":"AMVT60DP1300","price":2617.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/IMG-AVPTC_5a8119d1-d944-4bad-aa6c-45bb688845ee.jpg?v=1793681015","url":"https:\/\/www.acunitsforless.com\/products\/goodman-5-ton-r32-air-handler-amvt60dp1300","provider":"acunitsforless.com","version":"1.0","type":"link"}