{"product_id":"goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-100000-btu-96-afue-two-stage-furnace-gzv6sa4210-grvt961005dn-capea4830d3","title":"Goodman 3.5 Ton Up to 17.0 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA4210 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT961005DN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447235\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961005CN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447237\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT961005DN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447234\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118445277475,"sku":"GZV6SA4210-GRVT961005DN-CAPEA4830D3","price":8246.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118445310243,"sku":"GZV6SA4210-GDVT961005CN-CAPEA4830D3","price":8223.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118445343011,"sku":"GZV6SA4210-GRVT961005DN-CHPEA4830D3","price":8152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256","url":"https:\/\/www.acunitsforless.com\/products\/goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-100000-btu-96-afue-two-stage-furnace-gzv6sa4210-grvt961005dn-capea4830d3","provider":"acunitsforless.com","version":"1.0","type":"link"}