{"product_id":"daikin-nexio-max-7-5-ton-high-static-inverter-packaged-heat-pump-460v-dvh0904w000001s","title":"Daikin NEXIO MAX 7.5 Ton High Static Inverter Packaged Heat Pump 460V 3-Phase R-32 | DVH0904W000001S","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Daikin NEXIO MAX DVH0904W000001S is the 460V, 3-Phase high-static configuration of the 7.5 ton (90,000 BTU) DV Series inverter packaged heat pump — combining the reduced ampacity advantages of 460V electrical service with the 2.0 in. W.C. maximum external static pressure capability needed for demanding commercial duct systems. It delivers 22.0 IEER \/ 12.4 EER efficiency from a single variable-speed scroll inverter compressor on R-32 refrigerant, making it the highest-efficiency model in the initial NEXIO MAX DV Series release while simultaneously addressing both voltage and static pressure requirements in a single unit selection.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe DVH0904W occupies a specific but common specification niche: buildings that run 460V, 3-phase distribution and have duct systems — whether existing on a retrofit or designed for a high-resistance layout on new construction — that exceed the 1.4 in. W.C. ceiling of the standard-static platform. Selecting this model eliminates the need to choose between voltage compatibility and static pressure headroom. The 460V configuration keeps MCA at 24.8A and max overcurrent protection at 30A, while the high-static blower delivers 2,950 CFM nominal airflow against up to 2.0 in. W.C. of duct resistance through a direct-drive 3.5 HP motor at 7.2A FLA.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe inverter compressor continuously modulates speed to match real-time building load, eliminating fixed-speed on\/off cycling and maintaining tight temperature control across all occupancy conditions. A subcooling heat exchanger, vapor-injection solenoid, and electronic expansion valves on both indoor and outdoor coils optimize the refrigerant circuit across all operating modes: cooling, heating, defrost, oil return, and hot gas reheat on HGRH-configured models. A dedicated BACnet PCB is physically installed in the indoor control panel as standard for native BAS integration with no field-add cards required.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis unit ships to all 48 contiguous states via LTL freight from AC Units for Less, an authorized Daikin dealer. Contractor and B2B pricing available at business.acunitsforless.com. Call 678-535-7176 for lead times, freight quotes, or spec support.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpec Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDVH0904W000001S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin NEXIO MAX (DV Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInverter Packaged Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e90,000 BTU\/H (7.5 Tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e22.0 IEER \/ 12.4 EER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e335 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e460V – 3 Phase – 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax. Overcurrent Protection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1 \/ Scroll \/ Inverter Variable-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Nominal CFM\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2,950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Motor HP\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Blower FLA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e7.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax External Static Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2.0 in. W.C. (High Static)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e16.6 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Motors\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Diameter \/ Blades\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.3 in. \/ 3 Blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e27.0 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFilter Sizes\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e(2) 20×25×2 in. + (2) 25×25×2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDrain Connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3\/4 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.375 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow-Voltage Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.5 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBACnet MS\/TP (Dedicated PCB, Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIoT Platform\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin HERO Cloud Services \/ HERO Pro Edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,293 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eShip Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,365 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInstallation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRooftop, Horizontal, or Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNew Construction \u0026amp; Retrofit Curb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What makes the DVH0904W000001S different from the other 7.5-ton DV Series models?\u003c\/strong\u003e\u003cbr\u003eA: It combines two configuration upgrades in one unit: 460V, 3-Phase electrical service and 2.0 in. W.C. high-static capability. Compared to the base 208\/230V standard-static DVH0903D, it offers both reduced ampacity (24.8A MCA vs. 49.9A) and higher static pressure headroom (2.0 vs. 1.4 in. W.C.). All performance specs — 90,000 BTU, 22.0 IEER, 2,950 CFM, 335 oz. R-32 charge — are identical across all four 7.5-ton DV Series variants.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: When does the DVH0904W make more sense than the DVH0903W?\u003c\/strong\u003e\u003cbr\u003eA: When your building runs 460V, 3-phase distribution. The DVH0903W is the 208\/230V high-static model; the DVH0904W delivers identical high-static performance at 460V. Both handle 2.0 in. W.C. max external static with the same 3.5 HP blower — the only difference is voltage, ampacity, and the resulting wire and breaker sizing requirements.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Does the blower motor change between the 460V standard and 460V high-static 7.5-ton models?\u003c\/strong\u003e\u003cbr\u003eA: No. Both the DVH0904D (standard static) and DVH0904W (high static) use the same 3.5 HP direct-drive blower at 7.2A FLA. As with the 208\/230V 7.5-ton pair, the high-static capability at this tonnage comes from blower wheel and operating characteristics rather than a motor upgrade. The motor steps up to higher HP only on the 10 and 12-ton W configurations.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What are the electrical requirements?\u003c\/strong\u003e\u003cbr\u003eA: 460V, 3-Phase, 60 Hz. Minimum Circuit Ampacity (MCA) is 24.8A and maximum overcurrent protection is 30A — identical to the standard-static 460V DVH0904D. The high-static blower configuration does not change the electrical requirements at 7.5 tons and 460V. Power supply conduit knockout is 1.375 in. diameter; low-voltage conduit is 0.5 in. diameter.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the IEER efficiency rating?\u003c\/strong\u003e\u003cbr\u003eA: 22.0 IEER \/ 12.4 EER — the highest efficiency rating in the initial NEXIO MAX DV Series lineup, shared across all four 7.5-ton variants regardless of voltage or static pressure configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is BACnet MS\/TP standard on this model?\u003c\/strong\u003e\u003cbr\u003eA: Yes. All DV Series NEXIO MAX units include a dedicated BACnet PCB physically installed in the indoor control panel as standard. Native BAS integration requires no field-add communication cards regardless of voltage or static pressure configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: How does this unit compare to the 460V standard-static DVH0904D?\u003c\/strong\u003e\u003cbr\u003eA: The only difference is static pressure rating — 2.0 in. W.C. on the DVH0904W versus 1.4 in. W.C. on the DVH0904D. Electrical requirements, efficiency ratings, capacity, airflow, refrigerant charge, cabinet dimensions, and weight are all identical between the two 460V 7.5-ton models.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What does this unit weigh and how does it ship?\u003c\/strong\u003e\u003cbr\u003eA: Operating weight is 1,293 lbs. and ship weight is 1,365 lbs. — consistent across all twelve DV Series models. Units ship LTL freight to all 48 contiguous states. Call 678-535-7176 for a freight quote before ordering.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Where can I buy the Daikin NEXIO MAX DVH0904W000001S?\u003c\/strong\u003e\u003cbr\u003eA: AC Units for Less is an authorized Daikin dealer shipping to all 48 contiguous states. Contractor and B2B pricing is available at business.acunitsforless.com. Call 678-535-7176 for availability, lead times, and freight quotes\u003c\/p\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":55295926403363,"sku":"DVH0904W000001S","price":14583.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/daikinDfc_0a4e9bcc-13e9-40c5-9e56-de02541d433e.png?v=1782392973","url":"https:\/\/www.acunitsforless.com\/products\/daikin-nexio-max-7-5-ton-high-static-inverter-packaged-heat-pump-460v-dvh0904w000001s","provider":"acunitsforless.com","version":"1.0","type":"link"}