{"product_id":"daikin-nexio-max-10-ton-inverter-packaged-heat-pump-dvh1023d000001s","title":"Daikin NEXIO MAX 10 Ton Light Commercial Inverter Packaged Heat Pump 208\/230V 3-Phase R-32 | DVH1023D000001S","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Daikin NEXIO MAX DVH1023D000001S is a 10 ton (102,000 BTU) light commercial inverter packaged heat pump from the DV Series — the flagship tier of Daikin's NEXIO rooftop lineup. It delivers a rated efficiency of 21.0 IEER \/ 12.3 EER, powered by a single variable-speed scroll inverter compressor running on R-32 refrigerant. For building owners and specifiers stepping up from 7.5 tons to serve larger open-plan spaces, multi-room zones, or higher internal-load commercial environments, the 10-ton NEXIO MAX delivers the same inverter modulation and controls intelligence as the 7.5-ton platform at increased capacity.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe inverter compressor continuously modulates output to match real-time building load — eliminating the energy waste and temperature swings of fixed-speed on\/off cycling. A subcooling heat exchanger, vapor-injection solenoid, and multiple electronic expansion valves across the indoor and outdoor coils work in concert to optimize the refrigerant circuit across all operating modes: cooling, heating, defrost, oil return, and hot gas reheat on HGRH-configured models. The result is a unit that runs efficiently across the full range of part-load conditions that dominate real-world commercial operating hours.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe indoor section delivers 3,100 CFM nominal airflow through a direct-drive 3.5 HP blower motor (5.0 HP on the high-static DVH1023W variant), supporting up to 1.4 in. W.C. external static pressure in standard configuration. A dedicated BACnet PCB is physically installed in the indoor control panel as standard — not a field-add communication card — providing native BACnet MS\/TP integration with building automation systems without any additional hardware. Two condenser fan motors drive 21.3-inch, 3-blade fans across 27.0 sq. ft. of outdoor coil face area.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis unit ships to all 48 contiguous states via LTL freight from AC Units for Less, an authorized Daikin dealer. Contractors with recurring commercial volume can access B2B pricing at business.acunitsforless.com. Call 678-535-7176 for lead times, freight quotes, or spec support.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpec Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDVH1023D000001S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin NEXIO MAX (DV Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInverter Packaged Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e102,000 BTU\/H (10 Tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.0 IEER \/ 12.3 EER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e335 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208\/230V – 3 Phase – 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e52.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax. Overcurrent Protection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1 \/ Scroll \/ Inverter Variable-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Nominal CFM\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Motor HP\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Blower FLA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e11.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax External Static Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.4 in. W.C. (Standard ESP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e16.6 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Motors\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Diameter \/ Blades\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.3 in. \/ 3 Blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e27.0 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFilter Sizes\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e(2) 20×25×2 in. + (2) 25×25×2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDrain Connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3\/4 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.375 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow-Voltage Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.5 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBACnet MS\/TP (Dedicated PCB, Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIoT Platform\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin HERO Cloud Services \/ HERO Pro Edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,293 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eShip Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,365 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInstallation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRooftop, Horizontal, or Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNew Construction \u0026amp; Retrofit Curb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the IEER rating of the DVH1023D000001S?\u003c\/strong\u003e\u003cbr\u003eA: The DVH1023D000001S is rated at 21.0 IEER and 12.3 EER. The slight efficiency difference versus the 7.5-ton model (22.0 IEER) is normal as capacity scales up — both units are among the highest-efficiency options available in their respective size classes for light commercial packaged heat pumps.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the cooling capacity in BTU?\u003c\/strong\u003e\u003cbr\u003eA: 102,000 BTU\/H total cooling capacity at 10 nominal tons. This covers larger light commercial spaces typically ranging from 3,000 to 4,500+ sq. ft. depending on building envelope, occupancy, internal loads, and climate zone.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What refrigerant does the DVH1023D000001S use and what is the factory charge?\u003c\/strong\u003e\u003cbr\u003eA: R-32, with a factory charge of 335 oz. (approximately 20.9 lbs.) — the same refrigerant charge as the 7.5-ton DVH0903D. R-32 is an A2L low-GWP refrigerant with a Global Warming Potential of 675, roughly 68% lower than R-410A. All service personnel must hold current A2L refrigerant certification.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What are the electrical requirements?\u003c\/strong\u003e\u003cbr\u003eA: 208\/230V, 3-Phase, 60 Hz. Minimum Circuit Ampacity (MCA) is 52.7A and the maximum overcurrent protection device is 60A. Power supply conduit knockout is 1.375 in. diameter; low-voltage conduit is 0.5 in. diameter.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is BACnet MS\/TP included standard or an add-on?\u003c\/strong\u003e\u003cbr\u003eA: Factory-installed standard. The DVH1023D000001S includes a dedicated BACnet PCB physically mounted in the indoor control panel — confirmed in Daikin's service documentation for the DV Series. No field-add communication cards are needed for native BAS integration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the indoor airflow and blower motor size?\u003c\/strong\u003e\u003cbr\u003eA: 3,100 CFM nominal with a 3.5 HP direct-drive blower motor. The unit supports up to 1.4 in. W.C. external static pressure in the standard (DVH1023D) configuration. For applications requiring higher static pressure, the DVH1023W is the high-static variant at 2.0 in. W.C. with a 5.0 HP blower motor.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is there a high-static version of the 10-ton NEXIO MAX?\u003c\/strong\u003e\u003cbr\u003eA: Yes — the DVH1023W000001S is the high-static variant, rated at 2.0 in. W.C. maximum external static and equipped with a 5.0 HP indoor blower motor and 15.1A blower FLA versus 11.7A on the standard model. Contact us at 678-535-7176 to confirm availability.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: How does the 10-ton differ from the 7.5-ton NEXIO MAX?\u003c\/strong\u003e\u003cbr\u003eA: Capacity and airflow are the primary differences. The 10-ton (DVH1023D) delivers 102,000 BTU vs. 90,000 BTU and 3,100 CFM vs. 2,950 CFM. Electrical requirements step up slightly — MCA is 52.7A vs. 49.9A. Cabinet dimensions, operating weight (1,293 lbs.), ship weight (1,365 lbs.), refrigerant charge (335 oz.), coil configuration, and control architecture are shared across both platform sizes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What does this unit weigh and how does it ship?\u003c\/strong\u003e\u003cbr\u003eA: Operating weight is 1,293 lbs. and ship weight is 1,365 lbs. — identical to the 7.5-ton model, as both share the same cabinet platform. Units ship LTL freight. Call 678-535-7176 for a freight quote; liftgate and inside delivery options vary by carrier and delivery address.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Where can I buy the Daikin NEXIO MAX DVH1023D000001S?\u003c\/strong\u003e\u003cbr\u003eA: AC Units for Less is an authorized Daikin dealer shipping to all 48 contiguous states. Contractor and B2B pricing is available at business.acunitsforless.com. Call 678-535-7176 for availability, lead times, and freight quotes.\u003c\/p\u003e","brand":"acunitsforless.com","offers":[{"title":"Default Title","offer_id":55295893569827,"sku":"DVH1023D000001S","price":16157.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Dfcdaikin_975e5006-2ae8-4e99-ad47-a4e7b369e970.png?v=1782392973","url":"https:\/\/www.acunitsforless.com\/products\/daikin-nexio-max-10-ton-inverter-packaged-heat-pump-dvh1023d000001s","provider":"acunitsforless.com","version":"1.0","type":"link"}