{"product_id":"daikin-nexio-max-10-ton-inverter-packaged-heat-pump-460v-dvh1024d000001s","title":"Daikin NEXIO MAX 10 Ton Light Commercial Inverter Packaged Heat Pump 460V 3-Phase R-32 | DVH1024D000001S","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Daikin NEXIO MAX DVH1024D000001S is a 10 ton (102,000 BTU) light commercial inverter packaged heat pump from the DV Series configured for 460V, 3-Phase, 60 Hz electrical service. It delivers 21.0 IEER \/ 12.3 EER efficiency from a single variable-speed scroll inverter compressor on R-32 refrigerant — the same performance platform as the 208\/230V DVH1023D, with the key advantage of significantly reduced ampacity requirements that simplify panel sizing and wire gauge selection in commercial buildings already running 460V distribution.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eAt 460V, the minimum circuit ampacity drops to 26.0A and maximum overcurrent protection to 30A — compared to 52.7A MCA and 60A overcurrent on the 208\/230V counterpart. For building owners and electrical contractors working with existing 460V infrastructure or managing constrained panel capacity, the 460V configuration eliminates the need for panel upgrades or large-gauge wiring runs while delivering identical heating and cooling performance.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe inverter compressor continuously modulates speed to match real-time building load, eliminating the energy waste of fixed-speed on\/off cycling across the part-load hours that dominate commercial operating schedules. A subcooling heat exchanger, vapor-injection solenoid, and electronic expansion valves on both indoor and outdoor coils optimize the refrigerant circuit across all operating modes: cooling, heating, defrost, oil return, and hot gas reheat on HGRH-configured models. The indoor section delivers 3,100 CFM nominal airflow through a direct-drive 7\/8 HP blower at 7.2A FLA, supporting up to 1.4 in. W.C. external static pressure in standard configuration. A dedicated BACnet PCB is physically installed in the indoor control panel as standard for native BAS integration with no field-add cards required.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis unit ships to all 48 contiguous states via LTL freight from AC Units for Less, an authorized Daikin dealer. Contractor and B2B pricing available at business.acunitsforless.com. Call 678-535-7176 for lead times, freight quotes, or spec support.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpec Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDVH1024D000001S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin NEXIO MAX (DV Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInverter Packaged Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e102,000 BTU\/H (10 Tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.0 IEER \/ 12.3 EER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e335 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e460V – 3 Phase – 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e26.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax. Overcurrent Protection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1 \/ Scroll \/ Inverter Variable-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Nominal CFM\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Motor HP\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e7\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Blower FLA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e7.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax External Static Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.4 in. W.C. (Standard ESP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e16.6 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Motors\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Diameter \/ Blades\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.3 in. \/ 3 Blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e27.0 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFilter Sizes\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e(2) 20×25×2 in. + (2) 25×25×2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDrain Connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3\/4 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.375 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow-Voltage Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.5 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBACnet MS\/TP (Dedicated PCB, Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIoT Platform\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin HERO Cloud Services \/ HERO Pro Edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,293 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eShip Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,365 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInstallation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRooftop, Horizontal, or Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNew Construction \u0026amp; Retrofit Curb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the difference between the DVH1024D000001S and the DVH1023D000001S?\u003c\/strong\u003e\u003cbr\u003eA: Voltage only. The DVH1024D is configured for 460V, 3-Phase; the DVH1023D runs on 208\/230V, 3-Phase. All performance specs are identical — 102,000 BTU, 21.0 IEER, 12.3 EER, 3,100 CFM, 335 oz. R-32 charge, and 1,293 lb. operating weight. The 460V configuration reduces MCA from 52.7A to 26.0A and max overcurrent protection from 60A to 30A.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Why would I choose the 460V model over 208\/230V?\u003c\/strong\u003e\u003cbr\u003eA: If your building already has 460V, 3-phase distribution — standard in many larger commercial, industrial, and multi-tenant properties — the 460V model is the correct choice. The lower current draw (26.0A MCA vs. 52.7A) means smaller wire gauges, smaller breakers, and reduced demand on panel capacity. On retrofits where 208\/230V panel space is tight, the 460V unit can resolve an electrical bottleneck without requiring a panel upgrade.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the IEER efficiency rating?\u003c\/strong\u003e\u003cbr\u003eA: 21.0 IEER \/ 12.3 EER — identical to the 208\/230V DVH1023D. Voltage configuration has no effect on the unit's heating and cooling efficiency ratings.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What are the full electrical requirements?\u003c\/strong\u003e\u003cbr\u003eA: 460V, 3-Phase, 60 Hz. Minimum Circuit Ampacity (MCA) is 26.0A and maximum overcurrent protection is 30A. Power supply conduit knockout is 1.375 in. diameter; low-voltage conduit is 0.5 in. diameter.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is BACnet MS\/TP standard on the 460V model?\u003c\/strong\u003e\u003cbr\u003eA: Yes. All DV Series NEXIO MAX units include a dedicated BACnet PCB physically installed in the indoor control panel as standard. Native BAS integration requires no field-add communication cards regardless of voltage configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the indoor blower FLA on the 460V model?\u003c\/strong\u003e\u003cbr\u003eA: 7.2A — compared to 11.7A on the 208\/230V DVH1023D. Same motor, higher voltage, proportionally lower current — consistent with standard electrical principles across the DV Series platform.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is there a high-static 460V 10-ton version available?\u003c\/strong\u003e\u003cbr\u003eA: Yes — the DVH1024W000001S is the 460V high-static variant rated at 2.0 in. W.C. maximum external static pressure, with a higher-HP indoor blower motor at 10.6A FLA. Contact us at 678-535-7176 to confirm availability.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: How does the 10-ton 460V compare to the 7.5-ton 460V model?\u003c\/strong\u003e\u003cbr\u003eA: The DVH1024D delivers 102,000 BTU and 3,100 CFM versus 90,000 BTU and 2,950 CFM on the DVH0904D. The MCA steps up slightly from 24.8A to 26.0A. Cabinet dimensions, operating weight (1,293 lbs.), ship weight (1,365 lbs.), refrigerant charge (335 oz.), coil configuration, and full control architecture are shared across the entire DV Series platform.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What does this unit weigh and how does it ship?\u003c\/strong\u003e\u003cbr\u003eA: Operating weight is 1,293 lbs. and ship weight is 1,365 lbs. Units ship LTL freight to all 48 contiguous states. Call 678-535-7176 for a freight quote before ordering; liftgate and inside delivery options vary by carrier and delivery address.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Where can I buy the Daikin NEXIO MAX DVH1024D000001S?\u003c\/strong\u003e\u003cbr\u003eA: AC Units for Less is an authorized Daikin dealer shipping to all 48 contiguous states. Contractor and B2B pricing is available at business.acunitsforless.com. Call 678-535-7176 for availability, lead times, and freight quotes.\u003c\/p\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":55295905693987,"sku":"DVH1024D000001S","price":16208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/DBC.png?v=1782392828","url":"https:\/\/www.acunitsforless.com\/products\/daikin-nexio-max-10-ton-inverter-packaged-heat-pump-460v-dvh1024d000001s","provider":"acunitsforless.com","version":"1.0","type":"link"}