{"product_id":"daikin-nexio-max-10-ton-high-static-inverter-packaged-heat-pump-dvh1023w000001s","title":"Daikin NEXIO MAX 10 Ton Light Commercial Inverter Packaged Heat Pump 208\/230V 3-Phase High Static R-32 | DVH1023W000001S","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Daikin NEXIO MAX DVH1023W000001S is the high-static configuration of the 10 ton (102,000 BTU) DV Series inverter packaged heat pump, rated for up to 2.0 in. W.C. maximum external static pressure. It delivers 21.0 IEER \/ 12.3 EER efficiency from a single variable-speed scroll inverter compressor on R-32 refrigerant, with an upgraded 5.0 HP direct-drive indoor blower motor capable of pushing 3,100 CFM nominal airflow through duct systems that exceed the 1.4 in. W.C. ceiling of the standard DVH1023D platform.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe step up to 5.0 HP at the 10-ton W configuration reflects the real demands of high-static commercial applications at this capacity. Long supply duct runs serving large open-plan spaces, retrofit installations into older buildings with undersized ductwork, high-MERV filtration systems with meaningful pressure drop, VAV systems with zone pressure-dependent dampers, and multi-branch distribution layouts serving diverse tenant spaces all push static pressure requirements beyond what standard rooftop units can handle. The DVH1023W meets those demands without requiring a different cabinet, a different curb, or a different refrigerant system — it is the same inverter packaged heat pump platform with the blower hardware matched to the application.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe inverter compressor continuously modulates speed to match real-time building load, eliminating fixed-speed on\/off cycling across the part-load conditions that dominate commercial operating schedules. A subcooling heat exchanger, vapor-injection solenoid, and electronic expansion valves on both indoor and outdoor coils optimize the refrigerant circuit across all operating modes: cooling, heating, defrost, oil return, and hot gas reheat on HGRH-configured models. A dedicated BACnet PCB is physically installed in the indoor control panel as standard for native BAS integration with no field-add cards required.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis unit ships to all 48 contiguous states via LTL freight from AC Units for Less, an authorized Daikin dealer. Contractor and B2B pricing available at business.acunitsforless.com. Call 678-535-7176 for lead times, freight quotes, or spec support.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpec Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDVH1023W000001S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin NEXIO MAX (DV Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInverter Packaged Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e102,000 BTU\/H (10 Tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.0 IEER \/ 12.3 EER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e335 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208\/230V – 3 Phase – 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e56.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax. Overcurrent Protection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1 \/ Scroll \/ Inverter Variable-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Nominal CFM\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Motor HP\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Blower FLA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e15.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax External Static Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2.0 in. W.C. (High Static)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e16.6 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Motors\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Diameter \/ Blades\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.3 in. \/ 3 Blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e27.0 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFilter Sizes\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e(2) 20×25×2 in. + (2) 25×25×2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDrain Connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3\/4 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.375 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow-Voltage Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.5 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBACnet MS\/TP (Dedicated PCB, Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIoT Platform\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin HERO Cloud Services \/ HERO Pro Edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,293 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eShip Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,365 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInstallation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRooftop, Horizontal, or Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNew Construction \u0026amp; Retrofit Curb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the difference between the DVH1023W000001S and the DVH1023D000001S?\u003c\/strong\u003e\u003cbr\u003eA: External static pressure rating and blower motor. The DVH1023W is rated for 2.0 in. W.C. maximum external static versus 1.4 in. W.C. on the DVH1023D, and achieves this with an upgraded 5.0 HP blower motor at 15.1A FLA versus 3.5 HP \/ 11.7A on the standard model. The higher blower FLA drives MCA up from 52.7A to 56.5A and max overcurrent protection from 60A to 70A. All performance, refrigerant, capacity, and cabinet specs are otherwise identical.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: When should I specify the DVH1023W over the DVH1023D?\u003c\/strong\u003e\u003cbr\u003eA: Specify the W model when your duct system's calculated total external static pressure exceeds 1.4 in. W.C. At 10 tons serving larger commercial spaces, high-static scenarios are common — long supply runs to distant zones, older undersized ductwork on retrofits, high-MERV or HEPA filtration banks, VAV systems with pressure-dependent zone dampers, and multi-branch distribution layouts with significant fitting losses. Run a full duct static calculation before specifying; the W model adds blower capacity without changing anything else about the installation.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Why does the 10-ton W model step up to 5.0 HP when the 7.5-ton W model stays at 3.5 HP?\u003c\/strong\u003e\u003cbr\u003eA: At 7.5 tons, the 3.5 HP motor has sufficient capacity to deliver 2,950 CFM against 2.0 in. W.C. static. At 10 tons, pushing 3,100 CFM against the same 2.0 in. W.C. ceiling requires more blower power — hence the 5.0 HP motor. This pattern continues at 12 tons where the W model also uses the 5.0 HP \/ 15.1A configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the IEER efficiency rating?\u003c\/strong\u003e\u003cbr\u003eA: 21.0 IEER \/ 12.3 EER — identical to the standard-static DVH1023D. The high-static blower upgrade does not affect the unit's cooling or heating efficiency ratings.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What are the electrical requirements?\u003c\/strong\u003e\u003cbr\u003eA: 208\/230V, 3-Phase, 60 Hz. Minimum Circuit Ampacity (MCA) is 56.5A and maximum overcurrent protection is 70A — stepping up from 52.7A \/ 60A on the standard DVH1023D due to the higher blower motor FLA. Power supply conduit knockout is 1.375 in. diameter; low-voltage conduit is 0.5 in. diameter. Verify panel and breaker capacity against the W model's electrical requirements before substituting for a D model on an existing circuit.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is BACnet MS\/TP standard on the high-static model?\u003c\/strong\u003e\u003cbr\u003eA: Yes. All DV Series NEXIO MAX units include a dedicated BACnet PCB physically installed in the indoor control panel as standard. Native BAS integration requires no field-add communication cards regardless of static pressure configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is there a 460V high-static version of the 10-ton available?\u003c\/strong\u003e\u003cbr\u003eA: Yes — the DVH1024W000001S is the 460V, 3-Phase high-static variant with a 10.6A blower FLA at 460V. Contact us at 678-535-7176 to confirm availability.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What does this unit weigh and how does it ship?\u003c\/strong\u003e\u003cbr\u003eA: Operating weight is 1,293 lbs. and ship weight is 1,365 lbs. — identical across all DV Series models regardless of static pressure configuration. Units ship LTL freight to all 48 contiguous states. Call 678-535-7176 for a freight quote before ordering.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Where can I buy the Daikin NEXIO MAX DVH1023W000001S?\u003c\/strong\u003e\u003cbr\u003eA: AC Units for Less is an authorized Daikin dealer shipping to all 48 contiguous states. Contractor and B2B pricing is available at business.acunitsforless.com. Call 678-535-7176 for availability, lead times, and freight quotes.\u003c\/p\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":55295916081443,"sku":null,"price":16981.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/DBC.png?v=1782392828","url":"https:\/\/www.acunitsforless.com\/products\/daikin-nexio-max-10-ton-high-static-inverter-packaged-heat-pump-dvh1023w000001s","provider":"acunitsforless.com","version":"1.0","type":"link"}