{"product_id":"daikin-nexio-max-10-ton-high-static-inverter-packaged-heat-pump-460v-dvh1024w000001s","title":"Daikin NEXIO MAX 10 Ton Light Commercial Inverter Packaged Heat Pump 460V 3-Phase High Static R-32 | DVH1024W000001S","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Daikin NEXIO MAX DVH1024W000001S is the 460V, 3-Phase high-static configuration of the 10 ton (102,000 BTU) DV Series inverter packaged heat pump — delivering 21.0 IEER \/ 12.3 EER efficiency from a single variable-speed scroll inverter compressor on R-32 refrigerant, with a 5.0 HP direct-drive indoor blower rated for up to 2.0 in. W.C. maximum external static pressure. At 460V, the same 5.0 HP blower that draws 15.1A on the 208\/230V DVH1023W runs at 10.6A FLA — keeping MCA at 29.7A and max overcurrent protection at 35A, numbers that are highly manageable even in commercial panels with constrained capacity.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe DVH1024W addresses the intersection of three common commercial specification requirements simultaneously: the need for 10 tons of inverter-driven heating and cooling capacity, the static pressure demands of complex or high-resistance duct systems, and the electrical infrastructure reality of a 460V, 3-phase building. Selecting a single model that satisfies all three eliminates the field compromises that result from mismatched specifications — undersized static pressure leading to airflow deficits at commissioning, or voltage mismatches requiring transformer installations that add cost and complexity to the mechanical room.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe inverter compressor continuously modulates speed to match real-time building load, eliminating fixed-speed on\/off cycling across the part-load conditions that dominate commercial operating schedules at 10 tons. A subcooling heat exchanger, vapor-injection solenoid, and electronic expansion valves on both indoor and outdoor coils optimize the refrigerant circuit across all operating modes: cooling, heating, defrost, oil return, and hot gas reheat on HGRH-configured models. The indoor section delivers 3,100 CFM nominal airflow through the 5.0 HP blower at 10.6A FLA against up to 2.0 in. W.C. of duct resistance. A dedicated BACnet PCB is physically installed in the indoor control panel as standard for native BAS integration with no field-add cards required.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThis unit ships to all 48 contiguous states via LTL freight from AC Units for Less, an authorized Daikin dealer. Contractor and B2B pricing available at business.acunitsforless.com. Call 678-535-7176 for lead times, freight quotes, or spec support.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpec Table\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDVH1024W000001S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin NEXIO MAX (DV Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSystem Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInverter Packaged Heat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e102,000 BTU\/H (10 Tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.0 IEER \/ 12.3 EER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant Charge\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e335 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e460V – 3 Phase – 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMin. Circuit Ampacity (MCA)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e29.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax. Overcurrent Protection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1 \/ Scroll \/ Inverter Variable-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Nominal CFM\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3,100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Motor HP\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndoor Blower FLA\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax External Static Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2.0 in. W.C. (High Static)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e16.6 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEvaporator Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Motors\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Fan Diameter \/ Blades\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e21.3 in. \/ 3 Blades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Face Area\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e27.0 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCondenser Coil Configuration\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3 Rows Deep \/ 16 Fins per Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFilter Sizes\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e(2) 20×25×2 in. + (2) 25×25×2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDrain Connection\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3\/4 in. NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1.375 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eLow-Voltage Conduit Hole\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e0.5 in. diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBACnet MS\/TP (Dedicated PCB, Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIoT Platform\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDaikin HERO Cloud Services \/ HERO Pro Edge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,293 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eShip Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,365 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eInstallation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRooftop, Horizontal, or Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNew Construction \u0026amp; Retrofit Curb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What makes the DVH1024W000001S different from the other 10-ton DV Series models?\u003c\/strong\u003e\u003cbr\u003eA: It is the only 10-ton DV Series model combining 460V, 3-Phase electrical service with 2.0 in. W.C. high-static capability. Compared to the 208\/230V high-static DVH1023W, it delivers identical static pressure performance and blower HP (5.0 HP) at significantly lower current draw — 10.6A blower FLA versus 15.1A, and 29.7A MCA versus 56.5A. All four 10-ton DV Series variants share the same 102,000 BTU capacity, 21.0 IEER, 3,100 CFM airflow, 335 oz. R-32 charge, and 1,293 lb. operating weight.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: When does the DVH1024W make more sense than the DVH1023W?\u003c\/strong\u003e\u003cbr\u003eA: When your building has 460V, 3-phase distribution. Both models deliver the same high-static performance — 2.0 in. W.C. max ESP with a 5.0 HP blower — but the DVH1024W does it at 460V, reducing MCA from 56.5A to 29.7A and max overcurrent from 70A to 35A. On projects with multiple rooftop units, the cumulative panel capacity savings of specifying 460V across the RTU array can be significant.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Why does the blower FLA drop from 15.1A to 10.6A between the 208\/230V and 460V high-static 10-ton models?\u003c\/strong\u003e\u003cbr\u003eA: Same 5.0 HP motor, higher voltage. Per basic electrical principles, doubling the voltage roughly halves the current for the same power output. The DVH1023W runs its 5.0 HP blower at 208\/230V drawing 15.1A; the DVH1024W runs the same motor at 460V drawing 10.6A. The mechanical output — 3,100 CFM against 2.0 in. W.C. — is identical between the two.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What are the full electrical requirements?\u003c\/strong\u003e\u003cbr\u003eA: 460V, 3-Phase, 60 Hz. Minimum Circuit Ampacity (MCA) is 29.7A and maximum overcurrent protection is 35A. Power supply conduit knockout is 1.375 in. diameter; low-voltage conduit is 0.5 in. diameter. Note the MCA steps up from 26.0A on the 460V standard-static DVH1024D due to the higher-HP blower motor; verify panel and breaker capacity if substituting the W for a D model on an existing circuit.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What is the IEER efficiency rating?\u003c\/strong\u003e\u003cbr\u003eA: 21.0 IEER \/ 12.3 EER — identical across all four 10-ton DV Series variants regardless of voltage or static pressure configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Is BACnet MS\/TP standard on this model?\u003c\/strong\u003e\u003cbr\u003eA: Yes. All DV Series NEXIO MAX units include a dedicated BACnet PCB physically installed in the indoor control panel as standard. Native BAS integration requires no field-add communication cards regardless of voltage or static pressure configuration.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: How does the DVH1024W compare to the 460V high-static 7.5-ton DVH0904W?\u003c\/strong\u003e\u003cbr\u003eA: Capacity and blower motor are the primary differences. The DVH1024W delivers 102,000 BTU and 3,100 CFM with a 5.0 HP \/ 10.6A blower versus 90,000 BTU and 2,950 CFM with a 3.5 HP \/ 7.2A blower on the DVH0904W. MCA steps up from 24.8A to 29.7A and max overcurrent from 30A to 35A. Cabinet, weight, refrigerant charge, coil configuration, and controls architecture are shared across the entire DV Series platform.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: How does the DVH1024W compare to the 460V high-static 12-ton DVH1204W?\u003c\/strong\u003e\u003cbr\u003eA: The DVH1204W delivers 114,000 BTU and 3,600 CFM versus 102,000 BTU and 3,100 CFM on the DVH1024W. Both share the same 5.0 HP blower at 10.6A FLA and the same 460V high-static platform. MCA steps up slightly from 29.7A to 30.3A and max overcurrent from 35A to 35A at 12 tons.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: What does this unit weigh and how does it ship?\u003c\/strong\u003e\u003cbr\u003eA: Operating weight is 1,293 lbs. and ship weight is 1,365 lbs. — consistent across all twelve DV Series models. Units ship LTL freight to all 48 contiguous states. Call 678-535-7176 for a freight quote before ordering; liftgate and inside delivery options vary by carrier and delivery address.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eQ: Where can I buy the Daikin NEXIO MAX DVH1024W000001S?\u003c\/strong\u003e\u003cbr\u003eA: AC Units for Less is an authorized Daikin dealer shipping to all 48 contiguous states. Contractor and B2B pricing is available at business.acunitsforless.com. Call 678-535-7176 for availability, lead times, and freight quotes.\u003c\/p\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":55295937446179,"sku":"DVH1024W000001S","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.acunitsforless.com\/products\/daikin-nexio-max-10-ton-high-static-inverter-packaged-heat-pump-460v-dvh1024w000001s","provider":"acunitsforless.com","version":"1.0","type":"link"}