{"product_id":"briggs-stratton-200kw-standby-generator-120-240v-3-phase-700a-natural-gas-080027","title":"200kW Briggs \u0026 Stratton Standby Generator - 120\/240V, 700A Breaker, 3-Phase, Block Heater \u0026 Battery Charger Included - 3-Year Warranty","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBriggs \u0026amp; Stratton 200kW Standby Generator – 120\/240V Three-Phase Natural Gas Backup Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Briggs \u0026amp; Stratton 200kW Standby Generator (Model 080027) delivers the highest-capacity backup power in the Briggs \u0026amp; Stratton liquid-cooled lineup — engineered for manufacturing facilities, industrial operations, agricultural properties, and large commercial buildings running on 120\/240V three-phase electrical systems. When the grid fails, this unit restores three-phase power within seconds — keeping industrial motors, HVAC systems, compressors, commercial refrigeration, lighting, production machinery, and mission-critical infrastructure running without interruption.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003ePowered by a liquid-cooled, turbocharged Doosan 11.1L Inline-6 engine producing 315 gross horsepower at a steady 1,800 RPM, this 200kW unit represents a significant platform step up from the 150kW series — featuring a larger displacement six-cylinder engine, dual 1,000 CCA batteries, water-cooled exhaust manifold, and dramatically greater fuel and coolant capacity. At just 72 dB(A) no-load, it is the quietest unit in the entire Briggs \u0026amp; Stratton lineup despite being the most powerful. Natural gas operation connects directly to your existing utility supply — no on-site fuel storage, no refueling, and no fuel interruptions during extended outages.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eDSE 7310 Mk II Smart Controller\u003c\/strong\u003e\u003cbr\u003eThe integrated DSE 7310 Mk II controller provides web-based monitoring, RS232\/RS485 remote communications, configurable I\/O, a 250-event log, load switching, load shedding, integral PLC editor, runtime scheduling, and full power monitoring (kW, kVA, kVAR) — giving facility managers and electrical contractors complete operational visibility and control from on-site or remotely.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBlock Heater \u0026amp; Battery Charger Included\u003c\/strong\u003e\u003cbr\u003eBoth accessories come standard. The block heater maintains engine temperature for reliable cold-weather starts, while the Guest 5-amp battery charger keeps both 1,000 CCA starting batteries at peak charge — ensuring the system is always primed and ready when you need it most.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpec\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStandby Rating\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e200 kW \/ 250 kVA @ 0.8 pf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e120\/240V, 3-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBreaker\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e700A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRunning Amperage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e601A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEngine\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDoosan 11.1L Inline-6, Turbocharged, 1,800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDisplacement\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e11.1L \/ 673 ci\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBore \u0026amp; Stroke\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e4.84 × 6.1 in \/ 123 × 155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompression Ratio\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10.5:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRated Horsepower\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e315 gross hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNumber of Cylinders\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e6 (Inline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eGovernor Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eElectronic, Isochronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFrequency Regulation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSteady State ±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIgnition System\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIndividual Ignition Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eExhaust Manifold\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eWater-Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNatural Gas (NG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFuel Supply Line Inlet\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFuel Supply Pressure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e7–11 in H₂O \/ 17–28 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFull-Load Fuel Use\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2,716 ft³\/hr (76.9 m³\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHalf-Load Fuel Use\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,494 ft³\/hr (42.4 m³\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eNo-Load Fuel Use\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e407 ft³\/hr (11.6 m³\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSound Level\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e72 dB(A) @ 7m, no-load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eAlternator\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMeccAlte ECO38-3SN\/4A, Brushless 12-Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTHD\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e\u0026lt; 3.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e±1.0% NL to FL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOne-Step Load Acceptance\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e100% of Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSustained Short-Circuit Current\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e300% of Rated Current for 20 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOil Capacity\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e25L \/ 26.5 qt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOil Filter\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1 \/ Cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCoolant Capacity (Total)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e105L \/ 92 qt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBattery\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e2 × 12V, 1,000 CCA (24V System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStarter Motor Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBattery Charger\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eGuest 5-Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e162 × 60 × 96 in \/ 4115 × 1524 × 2438 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e9,325 lb \/ 4,230 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSteel, Sound-Attenuated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCertifications\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eUL, cUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e3-Year Parts, Labor \u0026amp; Travel (Generator \u0026amp; Engine)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003e700A Breaker for Three-Phase Industrial and Manufacturing Loads\u003c\/strong\u003e\u003cbr\u003eThe factory-installed 700A breaker provides robust overload protection and simplified connection to your 120\/240V three-phase distribution panel. With 601A running amperage across three phases, this unit confidently handles industrial motors, compressors, large HVAC systems, commercial refrigeration, agricultural equipment, and manufacturing loads common in light industrial, farming, and production environments.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe 120\/240V three-phase configuration makes this unit the right choice for facilities with existing 120\/240V three-phase infrastructure — common in manufacturing plants, machine shops, agricultural operations, and light industrial environments. The sound-attenuated steel enclosure and water-cooled exhaust manifold contribute to the unit's exceptionally quiet 72 dB(A) no-load operation — the lowest sound rating in the entire Briggs \u0026amp; Stratton liquid-cooled lineup. Integral vibration isolation ensures smooth, stable operation. The 2\" NPT fuel inlet accommodates the high gas flow demands of the 200kW output; verify utility gas supply capacity before installation. Optional accessories include remote annunciator kits (DSE 2548-01), remote display module (DSE 2510-32), communication interface (DSE 890-01), AVR communication cable, battery warmer, battery cable lockout, and emergency stop switches (NEMA 4X).\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 080027\u003cbr\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 3-Year Parts, Labor \u0026amp; Travel\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhat can the Briggs \u0026amp; Stratton 200kW 080027 generator power?\u003c\/strong\u003e\u003cbr\u003eWith 200kW \/ 601A of three-phase output at 120\/240V, this generator is sized for manufacturing facilities, industrial operations, large agricultural properties, and heavy commercial buildings with 120\/240V three-phase electrical systems. It simultaneously powers industrial motors, compressors, large HVAC systems, commercial refrigeration, lighting, production machinery, and other critical three-phase loads during an outage — making it the highest-capacity 120\/240V three-phase option in the Briggs \u0026amp; Stratton lineup.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhat is the difference between the 080027 and the 080026?\u003c\/strong\u003e\u003cbr\u003eBoth are 200kW natural gas three-phase units on the same Doosan 11.1L Inline-6 engine platform. The key difference is voltage configuration: the 080027 uses a 120\/240V three-phase configuration (700A breaker, 601A running) suited for industrial, agricultural, and manufacturing facilities, while the 080026 uses a 120\/208V three-phase configuration (800A breaker, 694A running) suited for large commercial buildings, data centers, and healthcare campuses. The correct choice depends entirely on your facility's existing electrical infrastructure — confirm with your licensed electrician before ordering.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhat fuel type does the 080027 use and what are the supply requirements?\u003c\/strong\u003e\u003cbr\u003eThis generator runs on natural gas (NG) only. The fuel supply line inlet is 2\" NPT and requires a supply pressure of 7–11 in H₂O (17–28 mbar). Full-load fuel consumption is approximately 2,716 ft³\/hr (76.9 m³\/hr). Verify your utility gas supply capacity and line sizing can support this demand before installation — a licensed gas contractor should confirm adequate flow at the meter before ordering.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eDoes the Briggs \u0026amp; Stratton 080027 include an automatic transfer switch?\u003c\/strong\u003e\u003cbr\u003eAn automatic transfer switch (ATS) is not included but is available separately. When paired with a compatible ATS, this generator activates automatically within seconds of detecting a utility power failure — with no manual intervention required.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eWhat does the 3-year warranty cover?\u003c\/strong\u003e\u003cbr\u003eThe Briggs \u0026amp; Stratton 3-year limited warranty covers parts, labor, and travel for the generator and engine. Enclosure rust-through is covered for 2 years. Confirm complete warranty terms in the operator's manual or at BRIGGSandSTRATTON.com.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55286743269667,"sku":"080027","price":90976.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/200kWBriggs_StrattonStandbyGenerator-120240V_700ABreaker_3-Phase_BlockHeater_BatteryChargerIncluded-3-YearWarranty_2349f46c-23a9-4483-b0e5-b4e00e3e8bc2.png?v=1782719411","url":"https:\/\/www.acunitsforless.com\/products\/briggs-stratton-200kw-standby-generator-120-240v-3-phase-700a-natural-gas-080027","provider":"acunitsforless.com","version":"1.0","type":"link"}