{"product_id":"briggs-stratton-040794-22kw-generator-dual-200a-transfer-switch","title":"Briggs \u0026 Stratton 040794 22kW PowerProtect+ Generator with Dual 200A SE Transfer Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel Number: 040794\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect homes with multiple electrical panels using the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040794 22kW PowerProtect™ Standby Generator with Dual 200 Amp Service Entrance Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This residential standby-power package combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW automatic generator with two 200 Amp service-entrance-rated transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing greater installation flexibility for properties with multiple electrical panels or more complex electrical-service configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120\/240V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 22kW provides substantial backup capacity for residential applications. Depending on total electrical demand and system configuration, it can support central HVAC equipment, refrigeration, pumps, lighting, appliances, electronics, security systems, and other important household loads during a utility outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt the heart of the system is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard® V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, engineered for reliable standby operation. Combined with dual-fuel capability, full-pressure lubrication, low-THD electrical output, automatic controls, and a corrosion-resistant aluminum enclosure, the 040794 provides a comprehensive foundation for residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e22kW Standby Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides substantial backup capacity for medium to large residential applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual 200 Amp SE Transfer Switches Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two service-entrance-rated automatic transfer switches provide additional flexibility for homes with multiple electrical panels or compatible multi-panel configurations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e120\/240V Single-Phase Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential electrical applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The transfer system monitors utility power and automatically initiates generator operation when an outage occurs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® V-Twin Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Briggs \u0026amp; Stratton commercial-grade engine technology designed for dependable standby operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e3,600 RPM Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered for residential standby-generator applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps provide consistent engine lubrication and long-term engine protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNatural Gas or Liquid Propane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel operation provides flexibility according to the property's available fuel source.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLess Than 5% THD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides stable electrical output with low total harmonic distortion for modern household equipment and electronics.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQuiet Residential Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 64 dBA during low-idle operation and 68 dBA during normal operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProgrammable Exercise Cycle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the generator to periodically operate to help maintain system readiness.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdvanced Generator Controller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides operating information, system status, and diagnostic feedback.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for operation from approximately -20°F to 104°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for long-term outdoor installation and protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-Wind-Rated Enclosure Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built for applications requiring additional consideration for severe weather conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUL and cUL Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed and tested to applicable safety standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e6-Year Limited Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBackup Power for Homes with Multiple Electrical Panels\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe major difference between the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040794\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a conventional single-transfer-switch package is the inclusion of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo 200 Amp service entrance transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSome larger homes and properties have multiple electrical panels or electrical-service configurations that require more than one transfer switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch configuration provides installers with additional flexibility when integrating the standby generator into these electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can make the 040794 particularly useful for properties with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMultiple main electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpanded residential electrical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge homes with distributed electrical loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible multi-panel service configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperties where a single transfer switch does not meet the installation requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe appropriate configuration should always be determined from the property's actual electrical-service design.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant: Dual 200 Amp Transfer Switches Do Not Mean 400 Amps of Generator Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two transfer switches determine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehow electrical loads can be transferred between utility and generator power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. They do not increase the electrical output of the generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040794 remains a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor example, a property may have two electrical panels connected through the appropriate transfer configuration, but the combined electrical demand placed on the generator must remain within the generator's available capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf potential demand exceeds generator capacity, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eload management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may be necessary to prevent excessive loads from operating simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Backup Power During an Outage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility power is operating normally, the home's electrical system receives electricity from the utility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf an outage occurs, the automatic transfer system detects the loss of utility power and initiates generator startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOnce the PowerProtect generator is ready to supply electricity, the transfer system transitions the appropriate electrical loads from utility power to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the transfer system moves the electrical loads back to utility power and the generator completes its shutdown sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis automatic process allows the standby-power system to respond whether you're home or away.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e22kW of Residential Standby Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWith \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW of standby capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the Briggs \u0026amp; Stratton 040794 is designed for homes with substantial backup-power requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on individual equipment requirements and total electrical demand, a properly configured system may support equipment such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral air-conditioning systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerators and freezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWell and sump pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTVs and household electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected high-demand appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEssential circuits across multiple electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe amount of equipment that can operate simultaneously depends on the combined running and starting requirements of the connected loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for HVAC and Motor Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCentral HVAC equipment can represent one of the largest electrical demands in a home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir conditioners, heat pumps, compressors, pumps, and other motor-driven equipment may require significantly more power during startup than during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 22kW provides substantial residential standby capacity, making it suitable for consideration when maintaining heating and cooling is an important backup-power objective.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual HVAC compatibility should be determined using the equipment's electrical specifications and starting requirements rather than tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClean Power for Modern Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eModern residential electrical systems contain sensitive electronic components throughout the home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComputers, televisions, Wi-Fi equipment, security systems, smart-home devices, HVAC control boards, and modern appliances all benefit from stable electrical power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040794 is specified to produce \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern household equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton PowerProtect 22kW is designed to operate on either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNatural gas may be convenient for properties already connected to an appropriately sized utility gas service, while propane provides another option for properties without natural-gas availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fuel supply must be properly sized according to generator demand, fuel type, piping distance, pressure, local conditions, and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDurable Outdoor Construction\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause standby generators remain outdoors throughout the year, enclosure construction is an important consideration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040794 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecorrosion-resistant aluminum enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to protect the generator's internal components from outdoor conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications also identify a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-wind-rated enclosure design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making the system suitable for consideration in areas where severe-weather installation requirements are important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate across temperatures ranging from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Residential Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list the following approximate operating sound levels:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Condition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNormal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will vary depending on generator placement, distance, nearby structures, terrain, and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Exercise and System Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA standby generator may remain unused for extended periods between utility outages.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect system includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprogrammable exercise cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the generator to periodically operate and help verify system readiness.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts advanced controller also provides operating information, diagnostic feedback, and system status information for homeowners and service professionals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e040794\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandby Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard V-Twin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLubrication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTotal Harmonic Distortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switches Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes – Two\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp Each\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eService Entrance Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Low Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Normal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-Resistant Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eListings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWhy does the Briggs \u0026amp; Stratton 040794 include two 200 Amp transfer switches?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch configuration is intended to provide greater installation flexibility for properties with multiple electrical panels or compatible electrical-service configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe exact use of each transfer switch depends on the property's electrical design and should be determined by a qualified installer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDo two 200 Amp transfer switches make this a 400 Amp generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer-switch ratings should not be added together to determine generator output. The generator remains rated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, regardless of the number of transfer switches installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switches manage how compatible electrical systems transition between utility and generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the 22kW generator power both electrical panels?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch configuration can provide generator access to loads across compatible multiple-panel installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, the combined load placed on the generator must remain within its available capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf the potential demand across both panels exceeds generator output, appropriate load management may be required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the Briggs \u0026amp; Stratton 040794 power an entire house?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, depending on the home's electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA 22kW generator provides substantial residential backup capacity, but homes with multiple HVAC systems, electric heat, water heaters, ranges, dryers, pool equipment, EV chargers, or other large electrical loads may exceed generator capacity if too many loads operate simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation should be performed to determine the appropriate system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan this generator operate central air conditioning?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, yes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatibility depends on the HVAC equipment's running requirements, motor-starting demand, other simultaneous electrical loads, and overall system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHVAC compatibility should be determined from the actual electrical specifications of the equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the generator automatically start during an outage?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. When properly installed with the automatic transfer system, the generator is designed to automatically respond to a utility outage and provide backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the system transfers the electrical loads back to utility power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat fuel does the Briggs \u0026amp; Stratton 040794 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing flexibility according to available fuel infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it provide clean power for electronics?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern residential equipment and electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow loud is the 22kW PowerProtect generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e64 dBA during low-idle operation and 68 dBA during normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual sound experienced at the property will depend on installation location and surrounding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton PowerProtect Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor homes with multiple electrical panels or more complex electrical-service configurations, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040794 22kW PowerProtect Standby Generator with Dual 200 Amp SE Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a flexible foundation for automatic residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW of standby capacity, dual 200 Amp service entrance transfer switches, Vanguard V-Twin engine technology, natural gas or propane operation, low-THD electrical output, automatic controls, and durable aluminum construction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton PowerProtect standby generators, automatic transfer switches, power-management equipment, and generator accessories at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual transfer switches do not increase generator output. Generator sizing, connected loads, HVAC compatibility, fuel-system capacity, transfer-switch configuration, and installation requirements should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions and applicable electrical, fuel-gas, and building codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655852835107,"sku":"040794","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/BAS_ES_PPP18_F-ATS__19378_33eb62be-8cb5-4470-9493-79d80f0bac88.jpg?v=1790360584","url":"https:\/\/www.acunitsforless.com\/products\/briggs-stratton-040794-22kw-generator-dual-200a-transfer-switch","provider":"acunitsforless.com","version":"1.0","type":"link"}