{"title":"Briggs \u0026 Stratton Generators for Large Homes","description":"\u003cp\u003eBriggs \u0026amp; Stratton 26kW PowerProtect+ home standby generators suit homes of 3,000 sq ft and up with two or more central air conditioners and electric appliances. Choose a generator only (040807, or the 040810 PowerProtect DX) if you already have a transfer switch, or the 040814 kit with dual 200A transfer switches for homes with 400A split service.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVery large or all-electric home?\u003c\/strong\u003e Pair the generator with Symphony II power management so the biggest loads take turns instead of overloading it; see \u003ca href=\"\/es\/collections\/briggs-stratton-power-management-modules\"\u003epower management modules\u003c\/a\u003e. Two 200A panels? See \u003ca href=\"\/es\/collections\/briggs-stratton-generator-400-amp-service\"\u003egenerators for 400A split service\u003c\/a\u003e. Smaller home? See \u003ca href=\"\/es\/collections\/briggs-stratton-generator-mid-size-homes\"\u003emid-size homes\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSee the full range in \u003ca href=\"\/es\/collections\/briggs-stratton-residential-standby-generators\"\u003eBriggs \u0026amp; Stratton Residential Standby Generators\u003c\/a\u003e. Sizing here is a starting point; a licensed electrician should complete a load calculation before installation. Questions? Call 678-535-7176.\u003c\/p\u003e","products":[{"product_id":"briggs-stratton-26kw-powerprotect-plus-standby-generator-dual-fuel-7-year-warranty-040807","title":"26kW Briggs \u0026 Stratton PowerProtect+ Standby Generator - 120\/240V, Dual Fuel (LP\/NG), Vanguard Engine, 7-Year Warranty - Model 040807","description":"\u003cdiv style=\"border:1px solid #d1d5db;background:#f9fafb;border-radius:8px;padding:14px 16px;margin:0 0 20px;\"\u003e\n\u003cp style=\"margin:0 0 8px;\"\u003e\u003cstrong\u003eBefore you buy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:20px;line-height:1.6;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransfer switch required, sold separately.\u003c\/strong\u003e An automatic transfer switch (ATS) is needed for automatic operation. \u003ca href=\"https:\/\/www.acunitsforless.com\/collections\/briggs-stratton-transfer-switches\"\u003eShop Briggs \u0026amp; Stratton transfer switches\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShips by LTL freight\u003c\/strong\u003e on a pallet. Plan for a lift-gate or equipment to move the unit to its pad.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional installation:\u003c\/strong\u003e install by a licensed electrician and gas fitter, with permits as required by your local code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuestions or sizing help?\u003c\/strong\u003e Call us at \u003ca href=\"tel:6785357176\"\u003e678-535-7176\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin:24px 0 10px;font-size:1.25em;\"\u003eBriggs \u0026amp; Stratton 26kW PowerProtect+ Standby Generator – Maximum Whole-Home Backup for Large Homes and Luxury Properties\u003c\/h2\u003e\n\u003cp\u003eThe Briggs \u0026amp; Stratton 26kW PowerProtect+ Standby Generator (Model 040807) is the highest-capacity residential standby generator in the PowerProtect+ lineup — engineered for large homes, luxury estates, and properties with multiple HVAC systems, high electrical demands, and zero tolerance for outage-related disruption. When the grid fails, this generator detects the outage and restores 120\/240V power within seconds, keeping every critical system in your home running exactly as if the power never went out.\u003c\/p\u003e\n\u003cp\u003ePowered by a Briggs \u0026amp; Stratton Vanguard® V-twin engine running at 3,600 RPM with full pressure lubrication, the 040807 delivers 26kW of stable, clean output on both natural gas and liquid propane — providing utility-quality power with less than 5% THD that is safe for sensitive electronics, smart home systems, medical equipment, and modern appliances. With 65.5 kVA of motor starting capability — the highest in the PowerProtect+ residential lineup — this generator handles multiple simultaneous large motor startups without hesitation.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003eExclusive Front-Facing Exhaust\u003c\/h3\u003e\n\u003cp\u003eOnly Briggs \u0026amp; Stratton offers standby generators engineered to direct exhaust away from your home and landscaping. The front-facing exhaust design on the 040807 gives you more installation placement flexibility than any competing generator — protecting your home's exterior and landscaping while meeting tight clearance requirements in space-constrained installations.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003e65.5 kVA Motor Starting Power — Best in the Lineup\u003c\/h3\u003e\n\u003cp\u003eWith 65.5 kVA of motor starting capability, the 040807 is the most powerful starter in the PowerProtect+ residential lineup — 45% more starting power than the 22kW 040787 (45 kVA) and 77% more than the 13kW 040746 (37 kVA). It effortlessly handles multiple large HVAC systems, well pumps, sump pumps, pool equipment, and other motor-driven loads starting simultaneously — the scenario most likely to cause competing generators to trip or shut down during an outage.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003eEnergyTrak™ Integrated Remote Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe built-in EnergyTrak™ app lets you monitor your generator's status from anywhere and enables your dealer to remotely troubleshoot and diagnose issues without an in-person service call — faster resolution, less downtime, and complete peace of mind whether you're home or away.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003eEco-Cise™ Weekly Exercise Mode\u003c\/h3\u003e\n\u003cp\u003eThe programmable exercise cycle — configurable from 16 seconds to 20 minutes — automatically verifies the generator is ready for the next outage. The short 16-second mode minimizes noise and fuel consumption; longer cycles are available for installations requiring more thorough weekly verification.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 12px;font-size:1.1em;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;line-height:1.5;margin-bottom:24px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:10px 12px;background:#f3f4f6;border:1px solid #d1d5db;width:40%;\"\u003eSpec\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:10px 12px;background:#f3f4f6;border:1px solid #d1d5db;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eStandby Rating (LP)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e26 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eStandby Rating (NG)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e26 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eMotor Starting Power\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e65.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e120\/240V, Single-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eEngine\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eVanguard® V-Twin, OHV, Full Pressure Lubrication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eEngine Speed\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e3,600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eFrequency Regulation\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e±1% (Electronic Governor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e\u0026lt; 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eSound Level (Low Idle)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eSound Level (Normal Operation)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e-20°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eNatural Gas \/ LP Vapor (Dual Fuel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eExhaust Design\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eFront-Facing (exclusive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eWeekly Exercise Mode\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eEco-Cise™ 16 Seconds to 20 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eRemote Monitoring\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eEnergyTrak™ (integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eController\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eGC-1032 with LED Display \u0026amp; Fault Code Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eCorrosion-Resistant Aluminum, 186 mph Wind Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eUL, cUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eEngineered \u0026amp; Assembled\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eTransfer Switch\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eRequired, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #e5e7eb;\"\u003e7-Year Parts, Labor \u0026amp; Travel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003e186 mph Wind-Rated Aluminum Enclosure\u003c\/h3\u003e\n\u003cp\u003eThe PowerProtect+ enclosure is wind-rated to 186 mph — built to withstand Category 5 hurricane-force conditions while protecting the engine and alternator inside. The corrosion-resistant aluminum construction requires no paint, produces no rust, and is engineered for decades of outdoor exposure in the harshest environments — from coastal hurricane zones to northern freeze-thaw climates. Operating range spans -20°F to 104°F for true year-round reliability across all North American climates.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003eClean Power for Every Device in Your Home\u003c\/h3\u003e\n\u003cp\u003eWith less than 5% THD and ±1% electronic governor frequency regulation, the 040807 delivers utility-quality electricity that is safe for every device in your home — computers, smart TVs, medical equipment, smart home hubs, EV chargers, and sensitive appliances that would be damaged by the voltage fluctuations produced by lesser generators. This is the standard that modern homes demand and the PowerProtect+ delivers it consistently.\u003c\/p\u003e\n\u003ch3 style=\"margin:24px 0 8px;font-size:1.1em;\"\u003e7-Year Warranty — The Best in the Industry\u003c\/h3\u003e\n\u003cp\u003eThe PowerProtect+ 040807 is backed by a 7-year comprehensive warranty covering parts, labor, and travel — the longest standard warranty in the residential standby generator industry, two full years longer than both Generac's 5-year and Kohler's 5-year warranties. Unlike competitors that reduce labor and travel coverage in later years, Briggs \u0026amp; Stratton maintains full coverage for the entire 7-year term. This is the most comprehensive warranty you can get on a home standby generator, period.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 040807\u003cbr\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 7-Year Parts, Labor \u0026amp; Travel\u003c\/p\u003e\n\u003chr style=\"border:0;border-top:1px solid #e5e7eb;margin:24px 0;\"\u003e\n\u003ch3 style=\"margin:24px 0 12px;font-size:1.1em;\"\u003eFAQ\u003c\/h3\u003e\n\u003cp style=\"margin-bottom:16px;\"\u003e\u003cstrong\u003eWhat can the Briggs \u0026amp; Stratton 26kW 040807 power in my home?\u003c\/strong\u003e\u003cbr\u003eWith 26kW of output and 65.5 kVA of motor starting power, the 040807 is designed for large homes and luxury estates with multiple HVAC systems, high-demand appliances, and whole-home backup requirements. It simultaneously powers multiple central air conditioners, heat pumps, electric ranges, refrigerators, freezers, sump pumps, well pumps, pool equipment, lighting, home offices, and entertainment systems — with enough headroom to handle multiple large motor startups at once.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;\"\u003e\u003cstrong\u003eHow does the 26kW 040807 compare to the 22kW 040787?\u003c\/strong\u003e\u003cbr\u003eBoth are PowerProtect+ units with 7-year warranties, front-facing exhaust, EnergyTrak monitoring, and 186 mph enclosures on the same Vanguard engine platform. The 040807 delivers 4kW more output and 65.5 kVA of motor starting power vs. 45 kVA on the 040787 — a 45% increase in starting capability. The 040807 is the right choice for homes with multiple HVAC systems, larger square footage, pool equipment, or well pumps. The \u003ca href=\"https:\/\/www.acunitsforless.com\/products\/briggs-stratton-22kw-powerprotect-plus-standby-generator-dual-fuel-7-year-warranty-040787\"\u003e040787\u003c\/a\u003e is the right choice for most large single-family homes with a single HVAC system and standard electrical loads.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;\"\u003e\u003cstrong\u003eDoes the 26kW generator produce the same power on natural gas and LP?\u003c\/strong\u003e\u003cbr\u003eYes — the 040807 delivers the full 26kW on both LP and natural gas, with no derating on either fuel. This is a genuine differentiator from competing generators that commonly derate 10–20% on natural gas. You get full rated power regardless of which fuel your installation uses.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;\"\u003e\u003cstrong\u003eHow quiet is the 040807 compared to competing generators?\u003c\/strong\u003e\u003cbr\u003eThe 040807 operates at just 63 dB in low idle mode and 65 dB during normal operation — making it one of the quietest high-capacity residential standby generators available. For reference, 65 dB is roughly equivalent to a normal conversation at close range. This makes the 040807 suitable for neighborhoods with HOA noise restrictions and properties where generator noise is a concern.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;\"\u003e\u003cstrong\u003eDoes the 040807 start automatically during a power outage?\u003c\/strong\u003e\u003cbr\u003eYes. When paired with a compatible automatic transfer switch (ATS), the 040807 continuously monitors utility power and starts automatically within seconds of detecting an outage — restoring power to your home with no manual intervention required. An ATS is required for automatic operation and is sold separately: \u003ca href=\"https:\/\/www.acunitsforless.com\/collections\/briggs-stratton-transfer-switches\"\u003esee Briggs \u0026amp; Stratton transfer switches\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:16px;\"\u003e\u003cstrong\u003eNot sure which size or transfer switch you need?\u003c\/strong\u003e\u003cbr\u003eCall our team at \u003ca href=\"tel:6785357176\"\u003e678-535-7176\u003c\/a\u003e and we'll help you match the generator and transfer switch to your home's electrical service.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55286774268195,"sku":"040807","price":7195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/26kWBriggs_StrattonPowerProtect_StandbyGenerator_7e908de0-4881-4874-a3fd-90152ad40de4.png?v=1782718777"},{"product_id":"briggs-stratton-powerprotect-plus-dx-26kw-standby-generator-040810","title":"Briggs \u0026 Stratton PowerProtect+ DX 26kW Standby Generator (040810)","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eWith the most starting power in the industry, the Briggs \u0026amp; Stratton® PowerProtect+ DX 26kW Standby Generator has enough muscle to handle the largest appliances, like a central AC, while keeping everything else in the home running during an outage. All PowerProtect+ generators are engineered to start a 5-ton air conditioner, delivering that power without forcing a step up to a larger, more expensive generator. \u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eA commercial-grade Vanguard® 993cc engine delivers 26kW on liquid propane and 24kW on natural gas — the highest-output tier in the PowerProtect+ line. This DX+ model carries the line's exclusive front-facing exhaust, directing fumes away from the home for safer, more flexible installation, along with a Dura-Zen™-coated aluminum enclosure for corrosion resistance in harsh outdoor conditions. The GC-1033 controller integrates EnergyTrak™ remote monitoring, putting real-time generator status in a smartphone app and letting installers remotely diagnose issues before a service visit. The Eco-Cise™ weekly self-test runs its short 16-second cycle to verify readiness with minimal noise and fuel draw.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003eBacked by Briggs \u0026amp; Stratton's flagship 10-year comprehensive warranty — parts, labor, and travel, no hidden service costs — this is the generator for large homes that can't afford to compromise on backup power.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eSpecs \u0026amp; Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpec\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eModel Number\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e040810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSeries\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePowerProtect+ DX 26kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eController\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eGC-1033 with EnergyTrak™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRated Power (LP)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e26 kW \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRated Power (NG)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24 kW \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRunning Amps (LP\/NG)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e91.7 A \/ 91.7 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e120\/240V single phase \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMain Circuit Breaker\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e125 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEngine\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBriggs \u0026amp; Stratton Vanguard, commercial-grade, 993cc \u003cspan class=\"inline-flex\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMotor Starting Capability\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e41 kVA (13% voltage dip) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e46.5\" x 26.8\" x 28.4\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e540 lbs \u003cspan class=\"inline-flex\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSound Level\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e65 dBA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFuel Use — LP (50% load)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e235,000 BTU\/hr \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFuel Use — NG (50% load)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e206,000 BTU\/hr \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eAluminum, Dura-Zen™ corrosion-resistant coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eExhaust\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eFront-facing (exclusive to PowerProtect+ line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRemote Monitoring\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eEnergyTrak™, integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eWarranty\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10-Year Comprehensive (parts, labor, travel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTransfer Switch\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eIs this the most powerful generator in the PowerProtect+ line?\u003c\/strong\u003e\u003cbr\u003eYes — 26kW is the top output tier, with the highest motor-starting capability in the family.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eWhy is the LP rating higher than the NG rating?\u003c\/strong\u003e\u003cbr\u003ePropane delivers more usable energy per unit volume than natural gas, so the same engine produces more output on LP — 26kW vs. 24kW here.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003eDoes it need a transfer switch?\u003c\/strong\u003e\u003cbr\u003eYes, sold separately — size it to the 125A main breaker and your home's total electrical load.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55411562479907,"sku":"040810","price":7802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Briggs_StrattonPowerProtect_DX26kWStandbyGenerator_040810_71ad5634-9825-4b98-861e-c7f1788a36ec.png?v=1785844795"},{"product_id":"briggs-stratton-040814-26kw-generator-dual-200a-transfer-switch","title":"Briggs \u0026 Stratton 040814 26kW PowerProtect+ Generator with Dual 200A SE Transfer Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel Number: 040814\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect larger homes and properties with complex electrical systems using the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040814 26kW PowerProtect™ Standby Generator with Dual 200 Amp Service Entrance Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This residential backup-power package combines a high-capacity \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW standby generator with two 200 Amp service-entrance-rated automatic transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing greater installation flexibility for homes with multiple electrical panels or expanded electrical-service requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120\/240V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 26kW is designed for demanding residential applications where maintaining HVAC, refrigeration, pumps, lighting, appliances, electronics, security systems, and other important loads during an outage is a priority.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system is powered by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard® V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and offers up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65.5 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping accommodate demanding motor loads such as air-conditioning equipment and pumps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWith dual-fuel operation, low total harmonic distortion, an advanced \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGC-1032 controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, quiet operation, and a corrosion-resistant aluminum enclosure rated for winds up to 186 mph, the Briggs \u0026amp; Stratton 040814 is designed for dependable automatic backup power in demanding residential applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e26kW Standby Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-capacity residential standby power designed for larger homes and demanding electrical loads.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual 200 Amp SE Transfer Switches Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two service-entrance-rated automatic transfer switches provide greater flexibility for compatible multi-panel electrical systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e120\/240V Single-Phase Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential electrical applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically responds to utility outages when properly installed with the included transfer-switch system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® V-Twin Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Briggs \u0026amp; Stratton engine technology engineered for dependable standby operation and long-term durability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e65.5 kVA Motor-Starting Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides substantial starting capability for demanding motor-driven equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNatural Gas or Liquid Propane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel operation allows the system to be configured around the property's available fuel source.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLess Than 5% THD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Produces stable electrical output with low total harmonic distortion for modern electronics and household equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectronic Governor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides ±1% frequency regulation for stable generator performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eGC-1032 Controller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Advanced generator controller provides system information, operating status, and diagnostic capabilities.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProgrammable Exercise Cycle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Exercise duration can be configured from approximately 16 seconds up to 20 minutes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQuiet Residential Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 63 dBA during low-idle operation and 65 dBA during normal operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps provide consistent engine lubrication and protection during extended operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for long-term outdoor installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUp to 186 MPH Wind Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Enclosure is designed for demanding installation environments and severe-weather applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for operation from approximately -20°F to 104°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUL and cUL Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed and tested to applicable safety standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e7-Year Limited Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHigh-Capacity Backup Power for Larger Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040814 PowerProtect 26kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for homeowners who require more backup capacity than smaller residential standby generators can provide.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on total electrical demand and system configuration, a properly designed 26kW standby system may support equipment such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral air-conditioning systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerators and freezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWell and sump pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTVs and household electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected high-demand appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEssential loads distributed across multiple electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual generator capacity depends on the combined running and starting requirements of all equipment operating at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDual 200 Amp Service Entrance Transfer Switches\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOne of the distinguishing features of the Briggs \u0026amp; Stratton 040814 package is the inclusion of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo 200 Amp service entrance transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSome larger properties use multiple electrical panels or more complex service configurations. A single automatic transfer switch may not provide the installation flexibility required for these systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch package can provide an installer with additional options for integrating generator backup power across compatible multi-panel electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration may be appropriate for properties with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMultiple main electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge homes with distributed electrical loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpanded residential electrical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible detached-building configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperties where the electrical design requires more than one automatic transfer switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe appropriate configuration depends on the property's electrical architecture and should be determined by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDual 200 Amp Transfer Switches Do Not Equal 400 Amps of Generator Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two transfer switches expand the ways the generator can be integrated into a property's electrical system. They \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edo not double the generator's electrical output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 remains a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW standby generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEven when two 200 Amp transfer switches provide access to loads across multiple panels, the combined electrical demand placed on the generator must remain within its available output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf potential demand exceeds generator capacity, an appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eload-management strategy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may be necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e65.5 kVA Motor-Starting Capability\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRunning wattage is only part of residential generator sizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEquipment containing motors and compressors can require significantly more electrical power for a short period during startup. Central air conditioners, heat pumps, well pumps, pool equipment, and other motor-driven loads are common examples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 provides up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65.5 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving the generator additional capacity for starting demanding residential equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can be particularly valuable for homeowners who consider maintaining HVAC operation an important part of their outage plan.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual equipment compatibility should always be determined using the electrical specifications of the connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for Residential HVAC Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHeating and cooling can represent a significant portion of a home's electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 26kW provides substantial standby capacity and motor-starting capability for residential applications where maintaining HVAC operation is important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, generator sizing should not be based solely on the nominal tonnage of an air conditioner or heat pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation should consider:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHVAC running amperage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompressor starting requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdditional household loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNumber of HVAC systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment operating simultaneously\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAvailable load-management equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis provides a more accurate picture of whether the generator can operate the desired equipment during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClean, Stable Power for Modern Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eToday's homes contain sensitive electronics throughout their electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComputers, televisions, networking equipment, security systems, smart-home devices, HVAC control boards, and modern appliances all rely on stable electrical power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 is specified to produce \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator also incorporates an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic governor with ±1% frequency regulation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping maintain consistent electrical performance as loads change.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 26kW is designed to operate using either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis provides flexibility when planning the installation around the property's available fuel infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNatural gas can provide a convenient option for homes with an appropriately sized utility gas service, while propane provides an alternative for properties without natural-gas availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fuel system must be appropriately sized according to generator demand, fuel type, piping distance, pressure, local conditions, and applicable installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdvanced GC-1032 Generator Controller\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGC-1032 controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides centralized monitoring and control of generator operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe controller provides operating information, system status, and diagnostic feedback that can assist homeowners and service professionals with monitoring generator performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProgrammable exercise functionality also allows the generator to periodically operate so the system can remain prepared between actual utility outages.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eExercise duration can be configured from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e16 seconds up to 20 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, depending on the selected system settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Residential Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDespite its high residential output, the PowerProtect 26kW is designed with residential sound levels in mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Condition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNormal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will vary according to generator placement, distance, nearby structures, terrain, and surrounding environmental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt for Demanding Outdoor Conditions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA standby generator remains outdoors throughout the year, making enclosure durability especially important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecorrosion-resistant aluminum enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to protect the generator's internal components from outdoor conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications identify the enclosure as having a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewind rating up to 186 mph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing additional consideration for installations in areas exposed to severe weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is also designed for operation across temperatures ranging from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFinal generator placement, mounting, anchoring, and installation requirements should always follow Briggs \u0026amp; Stratton instructions and applicable local codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e040814\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandby Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard V-Twin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLubrication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMotor-Starting Capability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 65.5 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTotal Harmonic Distortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency Regulation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eController\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGC-1032\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switches Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes – Two\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp Each\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eService Entrance Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Low Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Normal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-Resistant Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWind Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 186 mph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eListings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWhen Do You Need Dual 200 Amp Transfer Switches?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA dual-transfer-switch configuration may be appropriate when the property's electrical design requires more than one automatic transfer point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotential applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHomes with multiple main electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge residences with distributed electrical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEstates with expanded electrical infrastructure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible detached garages or accessory structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperties with high electrical demand distributed across multiple panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDual transfer switches should not automatically be assumed necessary simply because a property has subpanels. The appropriate transfer configuration depends on how the electrical service and panels are designed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWhy does the Briggs \u0026amp; Stratton 040814 include dual 200 Amp transfer switches?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two 200 Amp service entrance transfer switches provide additional flexibility for properties with compatible multiple-panel electrical configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThey allow an installer to integrate automatic backup power across electrical systems where a single transfer switch may not meet the property's requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDo two 200 Amp transfer switches provide 400 amps of generator power?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switches are rated according to the electrical service they are designed to transfer. They do not increase generator output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator itself remains rated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the combined loads operating from both panels must remain within available generator capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the 26kW generator power both electrical panels?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch system can provide generator access to loads across compatible multiple-panel installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, whether all connected equipment can operate simultaneously depends on total electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLoad management may be required when the combined demand exceeds generator capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan a 26kW generator power an entire large home?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, but this depends on the home's electrical loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA 26kW generator provides substantial residential backup capacity, but large homes may contain multiple HVAC systems, electric heating, electric water heaters, ranges, dryers, pool equipment, pumps, EV chargers, and other high-demand equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation should be used to determine the appropriate generator and load-management configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the Briggs \u0026amp; Stratton 040814 run central air conditioning?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, yes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator provides up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65.5 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which can be beneficial when starting motor-driven equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual HVAC compatibility depends on the air-conditioning equipment's running requirements, starting demand, other simultaneous loads, and overall system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat fuel does the Briggs \u0026amp; Stratton 040814 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe selected fuel system must be properly sized to supply the generator under the expected operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes this generator provide clean power?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e along with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e±1% frequency regulation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern household equipment and electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow loud is the Briggs \u0026amp; Stratton 26kW generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e63 dBA during low-idle operation and 65 dBA during normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will depend on generator placement and surrounding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the wind rating?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications identify the generator enclosure as having a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewind rating up to 186 mph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstallation requirements, including mounting and anchoring, should still be determined according to Briggs \u0026amp; Stratton instructions and applicable local building requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton 26kW Standby Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor larger homes and properties with multiple electrical panels, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040814 26kW PowerProtect Standby Generator with Dual 200 Amp SE Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a high-capacity foundation for automatic residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW of standby capacity, dual 200 Amp service entrance transfer switches, up to 65.5 kVA motor-starting capability, Vanguard V-Twin engine technology, natural gas or propane operation, low-THD electrical output, GC-1032 controls, and durable aluminum construction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect standby generators, automatic transfer switches, power-management equipment, and generator accessories at AC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual transfer switches expand transfer capability but do not increase the generator's 26kW output. Generator sizing, HVAC compatibility, fuel-system capacity, electrical loads, transfer-switch configuration, mounting, and installation requirements should be evaluated by qualified professionals according to manufacturer instructions and applicable codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655879246115,"sku":"040814","price":9287.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/BAS_ES_PPP18_F-ATS__19378_33eb62be-8cb5-4470-9493-79d80f0bac88.jpg?v=1790360584"},{"product_id":"briggs-stratton-30kw-fortress-liquid-cooled-standby-generator-076880","title":"30kW Briggs \u0026 Stratton Fortress Liquid-Cooled Standby Generator - 120\/240V, Dual Fuel (LP\/NG), 125A Breaker, 6-Year Warranty - Model 076880","description":"\u003cp\u003e\u003cstrong\u003eModel Number: 076880\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGet commercial-grade backup power for larger properties with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076880 30kW Fortress™ Liquid-Cooled Standby Generator\u003c\/strong\u003e. Built for large homes, estates, and small businesses, the Fortress 30kW delivers \u003cstrong\u003e30kW on LP and NG\u003c\/strong\u003e at 120\/240V single-phase, giving you the capacity to keep HVAC, pumps, kitchens, and whole-home loads running through an extended outage.\u003c\/p\u003e\n\u003cp\u003eAt its core is a \u003cstrong\u003eBriggs \u0026amp; Stratton 1.6L inline 4-cylinder, liquid-cooled\u003c\/strong\u003e engine designed for long run times and heavy loads that air-cooled generators are not built to sustain. A \u003cstrong\u003e125A\u003c\/strong\u003e main breaker, low-THD alternator, and corrosion-resistant enclosure round out a system designed for years of outdoor service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This is a generator-only package. An automatic transfer switch (sold separately) is required for automatic operation.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30kW Liquid-Cooled Standby Power:\u003c\/strong\u003e Rated 30kW on LP and NG for large residential and light-commercial loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel (LP \/ NG):\u003c\/strong\u003e Runs on liquid propane vapor or natural gas, based on the fuel available at the site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-Cooled Industrial Engine:\u003c\/strong\u003e Briggs \u0026amp; Stratton 1.6L inline 4-cylinder, liquid-cooled at 3,600 RPM, built for extended run times.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e125A Main Breaker:\u003c\/strong\u003e Integrated generator breaker sized for the unit's rated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240V Single-Phase Output:\u003c\/strong\u003e Matches standard residential and light-commercial single-phase service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess Than 5% THD:\u003c\/strong\u003e Clean, stable power for electronics, HVAC controls, and appliance control boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Standby Operation:\u003c\/strong\u003e Starts within seconds of an outage when paired with a compatible Briggs \u0026amp; Stratton automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymphony® II Power Management Compatible:\u003c\/strong\u003e Works with Symphony II load management to prioritize high-wattage appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfoHub™ \/ EnergyTrak™ Monitoring Ready:\u003c\/strong\u003e Supports Briggs \u0026amp; Stratton remote monitoring (subscription may be required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Outdoor Enclosure:\u003c\/strong\u003e Steel sound-attenuated enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Designed for ambient temperatures from approximately -20°F to 104°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2200 \/ CSA Rated:\u003c\/strong\u003e Rated in accordance with UL 2200 and CSA C22.2 No. 100-14.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-Year Limited Warranty (Parts, Labor \u0026amp; Travel):\u003c\/strong\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage. See manufacturer terms for details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose a Liquid-Cooled Generator?\u003c\/h2\u003e\n\u003cp\u003eAir-cooled home standby generators top out in the mid-20kW range. When a property's demand goes beyond that — multiple HVAC systems, electric heat, pool equipment, well pumps, a shop, or a small business — a liquid-cooled generator is the next step.\u003c\/p\u003e\n\u003cp\u003eLiquid cooling keeps engine temperatures stable under sustained heavy load, which makes the Fortress series better suited to long outages and high-demand properties than air-cooled units.\u003c\/p\u003e\n\u003ch2\u003e30kW of Backup Power for Large Properties\u003c\/h2\u003e\n\u003cp\u003eDepending on the property's total electrical demand, a properly configured 30kW standby system may support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple central air-conditioning or heat-pump systems\u003c\/li\u003e\n\u003cli\u003eElectric water heaters and ranges\u003c\/li\u003e\n\u003cli\u003eWell, sump, and pool pumps\u003c\/li\u003e\n\u003cli\u003eRefrigeration and freezers\u003c\/li\u003e\n\u003cli\u003eLighting, networking, and security systems\u003c\/li\u003e\n\u003cli\u003eDetached garages, workshops, and outbuildings\u003c\/li\u003e\n\u003cli\u003eSmall-business equipment, POS, and office loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual capacity depends on the combined running and starting requirements of all equipment operating at the same time. A professional load calculation should be used for sizing.\u003c\/p\u003e\n\u003ch2\u003eNatural Gas or Liquid Propane\u003c\/h2\u003e\n\u003cp\u003eThe Fortress 30kW is rated at the same 30kW output on both liquid propane and natural gas, so you don't give up capacity when running on utility gas.\u003c\/p\u003e\n\u003cp\u003eEstimated fuel use at 50% load is about 328,000 BTU\/hr on LP and 293,000 BTU\/hr on NG. Fuel supply, piping, and regulator sizing must be designed for the generator's full-load demand.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFortress™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e076880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid-Cooled Automatic Standby Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125A (LP \/ NG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton 1.6L inline 4-cylinder, liquid-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Horsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 gross hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Propane Vapor \/ Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e328,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e293,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess Than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Operating Sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71\" L x 32.3\" W x 37\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel sound-attenuated enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo – sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2200 \/ CSA C22.2 No. 100-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-Year Limited Warranty (Parts, Labor \u0026amp; Travel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the Briggs \u0026amp; Stratton 076880 include a transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. The 076880 is a generator-only package. A compatible Briggs \u0026amp; Stratton automatic transfer switch, sized for the property's electrical service, is required for automatic operation.\u003c\/p\u003e\n\u003ch3\u003eCan a 30kW generator power an entire house?\u003c\/h3\u003e\n\u003cp\u003eFor many large homes, yes. A 30kW unit has substantially more capacity than air-cooled standby generators, but whole-home coverage still depends on the total running and starting load. Homes with several HVAC systems, electric heat, or EV chargers may still need load management.\u003c\/p\u003e\n\u003ch3\u003eWhat is the output on natural gas vs. propane?\u003c\/h3\u003e\n\u003cp\u003eThe 076880 is rated 30kW on LP and 30kW on NG.\u003c\/p\u003e\n\u003ch3\u003eHow much fuel does it use?\u003c\/h3\u003e\n\u003cp\u003eEstimated consumption at 50% load is about 328,000 BTU\/hr on LP and 293,000 BTU\/hr on NG. Actual use varies with load, elevation, and cycling appliances.\u003c\/p\u003e\n\u003ch3\u003eHow loud is it?\u003c\/h3\u003e\n\u003cp\u003eBriggs \u0026amp; Stratton lists a normal operating sound level of about 66 dBA. Perceived sound depends on placement, distance, and surrounding structures.\u003c\/p\u003e\n\u003ch3\u003eIs this generator suitable for a small business?\u003c\/h3\u003e\n\u003cp\u003eYes. The Fortress 30kW is marketed for large residences and small-business applications on 120\/240V single-phase service. For three-phase service, a three-phase commercial model is required.\u003c\/p\u003e\n\u003ch3\u003eHow is it delivered?\u003c\/h3\u003e\n\u003cp\u003eAt 1,000 lbs assembled, this unit ships by freight and typically requires a loading dock, forklift, or crane for offloading. Plan site access and a concrete pad in advance.\u003c\/p\u003e\n\u003ch2\u003eShop Briggs \u0026amp; Stratton Fortress Generators at AC Units For Less\u003c\/h2\u003e\n\u003cp\u003ePower large homes and small businesses with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076880 30kW Fortress Liquid-Cooled Standby Generator\u003c\/strong\u003e. Shop Briggs \u0026amp; Stratton standby generators, automatic transfer switches, Symphony II power-management modules, and generator accessories at AC Units For Less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Generator sizing, transfer-switch selection, fuel-system capacity, pad and placement, and installation should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions, NFPA 37, and applicable electrical, fuel-gas, and building codes.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":56072894054691,"sku":"076880","price":14624.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/30kWBriggs_StrattonFortressLiquid-CooledStandbyGenerator-120240V_DualFuel_LPNG_125ABreaker_6-YearWarranty-Model076880.png?v=1794722382"},{"product_id":"briggs-stratton-35kw-fortress-liquid-cooled-standby-generator-076830","title":"35kW Briggs \u0026 Stratton Fortress Liquid-Cooled Standby Generator - 120\/240V, Dual Fuel (LP\/NG), 150A Breaker, 5-Year Warranty - Model 076830","description":"\u003cp\u003e\u003cstrong\u003eModel Number: 076830\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGet commercial-grade backup power for larger properties with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076830 35kW Fortress™ Liquid-Cooled Standby Generator\u003c\/strong\u003e. Built for large homes and small businesses, the Fortress 35kW delivers \u003cstrong\u003e35kW on LP and NG\u003c\/strong\u003e at 120\/240V single-phase, giving you the capacity to keep HVAC, pumps, kitchens, and whole-home loads running through an extended outage.\u003c\/p\u003e\n\u003cp\u003eAt its core is a \u003cstrong\u003ePSI 4.3L V6 industrial powertrain, liquid-cooled\u003c\/strong\u003e engine running at a low 1,800 RPM — half the speed of typical air-cooled standby units — for quieter, more fuel-efficient operation and longer engine life. A \u003cstrong\u003e150A\u003c\/strong\u003e main breaker, low-THD alternator, and corrosion-resistant enclosure round out a system designed for years of outdoor service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This is a generator-only package. An automatic transfer switch (sold separately) is required for automatic operation.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e35kW Liquid-Cooled Standby Power:\u003c\/strong\u003e Rated 35kW on LP and NG for large residential and light-commercial loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel (LP \/ NG):\u003c\/strong\u003e Runs on liquid propane vapor or natural gas, based on the fuel available at the site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-Cooled Industrial Engine:\u003c\/strong\u003e PSI 4.3L V6 industrial powertrain, liquid-cooled at 1,800 RPM, built for extended run times.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150A Main Breaker:\u003c\/strong\u003e Integrated generator breaker sized for the unit's rated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240V Single-Phase Output:\u003c\/strong\u003e Matches standard residential and light-commercial single-phase service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess Than 5% THD:\u003c\/strong\u003e Clean, stable power for electronics, HVAC controls, and appliance control boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Standby Operation:\u003c\/strong\u003e Starts within seconds of an outage when paired with a compatible Briggs \u0026amp; Stratton automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymphony® II Power Management Compatible:\u003c\/strong\u003e Works with Symphony II load management to prioritize high-wattage appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfoHub™ \/ EnergyTrak™ Monitoring Ready:\u003c\/strong\u003e Supports Briggs \u0026amp; Stratton remote monitoring (subscription may be required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Outdoor Enclosure:\u003c\/strong\u003e Automotive-grade galvanneal aluminum, powder-coat finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Designed for ambient temperatures from approximately -20°F to 104°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2200 \/ CSA Rated:\u003c\/strong\u003e Rated in accordance with UL 2200 and CSA C22.2 No. 100-14.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-Year Limited Warranty (Parts, Labor \u0026amp; Travel):\u003c\/strong\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage. See manufacturer terms for details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose a Liquid-Cooled Generator?\u003c\/h2\u003e\n\u003cp\u003eAir-cooled home standby generators top out in the mid-20kW range. When a property's demand goes beyond that — multiple HVAC systems, electric heat, pool equipment, well pumps, a shop, or a small business — a liquid-cooled generator is the next step.\u003c\/p\u003e\n\u003cp\u003eLiquid cooling keeps engine temperatures stable under sustained heavy load, which makes the Fortress series better suited to long outages and high-demand properties than air-cooled units.\u003c\/p\u003e\n\u003ch2\u003e35kW of Backup Power for Large Properties\u003c\/h2\u003e\n\u003cp\u003eDepending on the property's total electrical demand, a properly configured 35kW standby system may support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple central air-conditioning or heat-pump systems\u003c\/li\u003e\n\u003cli\u003eElectric water heaters and ranges\u003c\/li\u003e\n\u003cli\u003eWell, sump, and pool pumps\u003c\/li\u003e\n\u003cli\u003eRefrigeration and freezers\u003c\/li\u003e\n\u003cli\u003eLighting, networking, and security systems\u003c\/li\u003e\n\u003cli\u003eDetached garages, workshops, and outbuildings\u003c\/li\u003e\n\u003cli\u003eSmall-business equipment, POS, and office loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual capacity depends on the combined running and starting requirements of all equipment operating at the same time. A professional load calculation should be used for sizing.\u003c\/p\u003e\n\u003ch2\u003eNatural Gas or Liquid Propane\u003c\/h2\u003e\n\u003cp\u003eThe Fortress 35kW is rated at the same 35kW output on both liquid propane and natural gas, so you don't give up capacity when running on utility gas.\u003c\/p\u003e\n\u003cp\u003eEstimated fuel use at 50% load is about 262,000 BTU\/hr on LP and 258,000 BTU\/hr on NG. Fuel supply, piping, and regulator sizing must be designed for the generator's full-load demand.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFortress™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e076830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid-Cooled Automatic Standby Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145A (LP \/ NG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSI 4.3L V6 industrial powertrain, liquid-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Propane Vapor \/ Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e262,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e258,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess Than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Operating Sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91\" L x 39.4\" W x 41\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,541 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomotive-grade galvanneal aluminum, powder-coat finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo – sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2200 \/ CSA C22.2 No. 100-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-Year Limited Warranty (Parts, Labor \u0026amp; Travel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the Briggs \u0026amp; Stratton 076830 include a transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. The 076830 is a generator-only package. A compatible Briggs \u0026amp; Stratton automatic transfer switch, sized for the property's electrical service, is required for automatic operation.\u003c\/p\u003e\n\u003ch3\u003eCan a 35kW generator power an entire house?\u003c\/h3\u003e\n\u003cp\u003eFor many large homes, yes. A 35kW unit has substantially more capacity than air-cooled standby generators, but whole-home coverage still depends on the total running and starting load. Homes with several HVAC systems, electric heat, or EV chargers may still need load management.\u003c\/p\u003e\n\u003ch3\u003eWhat is the output on natural gas vs. propane?\u003c\/h3\u003e\n\u003cp\u003eThe 076830 is rated 35kW on LP and 35kW on NG.\u003c\/p\u003e\n\u003ch3\u003eHow much fuel does it use?\u003c\/h3\u003e\n\u003cp\u003eEstimated consumption at 50% load is about 262,000 BTU\/hr on LP and 258,000 BTU\/hr on NG. Actual use varies with load, elevation, and cycling appliances.\u003c\/p\u003e\n\u003ch3\u003eHow loud is it?\u003c\/h3\u003e\n\u003cp\u003eBriggs \u0026amp; Stratton lists a normal operating sound level of about 68 dBA. Perceived sound depends on placement, distance, and surrounding structures.\u003c\/p\u003e\n\u003ch3\u003eIs this generator suitable for a small business?\u003c\/h3\u003e\n\u003cp\u003eYes. The Fortress 35kW is marketed for large residences and small-business applications on 120\/240V single-phase service. For three-phase service, a three-phase commercial model is required.\u003c\/p\u003e\n\u003ch3\u003eHow is it delivered?\u003c\/h3\u003e\n\u003cp\u003eAt 1,541 lbs assembled, this unit ships by freight and typically requires a loading dock, forklift, or crane for offloading. Plan site access and a concrete pad in advance.\u003c\/p\u003e\n\u003ch2\u003eShop Briggs \u0026amp; Stratton Fortress Generators at AC Units For Less\u003c\/h2\u003e\n\u003cp\u003ePower large homes and small businesses with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076830 35kW Fortress Liquid-Cooled Standby Generator\u003c\/strong\u003e. Shop Briggs \u0026amp; Stratton standby generators, automatic transfer switches, Symphony II power-management modules, and generator accessories at AC Units For Less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Generator sizing, transfer-switch selection, fuel-system capacity, pad and placement, and installation should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions, NFPA 37, and applicable electrical, fuel-gas, and building codes.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":56072894546211,"sku":"076830","price":19917.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/35kWBriggs_StrattonFortressLiquid-CooledStandbyGenerator-120240V_DualFuel_LPNG_150ABreaker_5-YearWarranty-Model076830.png?v=1794722305"},{"product_id":"briggs-stratton-48kw-fortress-liquid-cooled-standby-generator-076850","title":"48kW Briggs \u0026 Stratton Fortress Liquid-Cooled Standby Generator - 120\/240V, Dual Fuel (LP\/NG), 200A Breaker, 6-Year Warranty - Model 076850","description":"\u003cp\u003e\u003cstrong\u003eModel Number: 076850\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGet commercial-grade backup power for larger properties with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076850 48kW Fortress™ Liquid-Cooled Standby Generator\u003c\/strong\u003e. Built for very large homes, estates, and small-to-medium businesses, the Fortress 48kW delivers \u003cstrong\u003e48kW on LP \/ 45kW on NG\u003c\/strong\u003e at 120\/240V single-phase, giving you the capacity to keep HVAC, pumps, kitchens, and whole-home loads running through an extended outage.\u003c\/p\u003e\n\u003cp\u003eAt its core is a \u003cstrong\u003ePSI 4.3L V6 industrial powertrain, liquid-cooled\u003c\/strong\u003e engine running at a low 1,800 RPM — half the speed of typical air-cooled standby units — for quieter, more fuel-efficient operation and longer engine life. A \u003cstrong\u003e200A\u003c\/strong\u003e main breaker, low-THD alternator, and corrosion-resistant enclosure round out a system designed for years of outdoor service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This is a generator-only package. An automatic transfer switch (sold separately) is required for automatic operation.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48kW Liquid-Cooled Standby Power:\u003c\/strong\u003e Rated 48kW on LP \/ 45kW on NG for large residential and light-commercial loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel (LP \/ NG):\u003c\/strong\u003e Runs on liquid propane vapor or natural gas, based on the fuel available at the site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-Cooled Industrial Engine:\u003c\/strong\u003e PSI 4.3L V6 industrial powertrain, liquid-cooled at 1,800 RPM, built for extended run times.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200A Main Breaker:\u003c\/strong\u003e Integrated generator breaker sized for the unit's rated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240V Single-Phase Output:\u003c\/strong\u003e Matches standard residential and light-commercial single-phase service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess Than 5% THD:\u003c\/strong\u003e Clean, stable power for electronics, HVAC controls, and appliance control boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Standby Operation:\u003c\/strong\u003e Starts within seconds of an outage when paired with a compatible Briggs \u0026amp; Stratton automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymphony® II Power Management Compatible:\u003c\/strong\u003e Works with Symphony II load management to prioritize high-wattage appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfoHub™ \/ EnergyTrak™ Monitoring Ready:\u003c\/strong\u003e Supports Briggs \u0026amp; Stratton remote monitoring (subscription may be required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Outdoor Enclosure:\u003c\/strong\u003e Automotive-grade galvanneal aluminum, powder-coat finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Designed for ambient temperatures from approximately -20°F to 104°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2200 \/ CSA Rated:\u003c\/strong\u003e Rated in accordance with UL 2200 and CSA C22.2 No. 100-14.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-Year Limited Warranty (Parts, Labor \u0026amp; Travel):\u003c\/strong\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage. See manufacturer terms for details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose a Liquid-Cooled Generator?\u003c\/h2\u003e\n\u003cp\u003eAir-cooled home standby generators top out in the mid-20kW range. When a property's demand goes beyond that — multiple HVAC systems, electric heat, pool equipment, well pumps, a shop, or a small business — a liquid-cooled generator is the next step.\u003c\/p\u003e\n\u003cp\u003eLiquid cooling keeps engine temperatures stable under sustained heavy load, which makes the Fortress series better suited to long outages and high-demand properties than air-cooled units.\u003c\/p\u003e\n\u003ch2\u003e48kW of Backup Power for Large Properties\u003c\/h2\u003e\n\u003cp\u003eDepending on the property's total electrical demand, a properly configured 48kW standby system may support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple central air-conditioning or heat-pump systems\u003c\/li\u003e\n\u003cli\u003eElectric water heaters and ranges\u003c\/li\u003e\n\u003cli\u003eWell, sump, and pool pumps\u003c\/li\u003e\n\u003cli\u003eRefrigeration and freezers\u003c\/li\u003e\n\u003cli\u003eLighting, networking, and security systems\u003c\/li\u003e\n\u003cli\u003eDetached garages, workshops, and outbuildings\u003c\/li\u003e\n\u003cli\u003eSmall-business equipment, POS, and office loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual capacity depends on the combined running and starting requirements of all equipment operating at the same time. A professional load calculation should be used for sizing.\u003c\/p\u003e\n\u003ch2\u003eNatural Gas or Liquid Propane\u003c\/h2\u003e\n\u003cp\u003eThe Fortress 48kW produces 48kW on liquid propane and 45kW on natural gas. Size the system using the rating for the fuel you plan to use.\u003c\/p\u003e\n\u003cp\u003eEstimated fuel use at 50% load is about 337,000 BTU\/hr on LP and 328,000 BTU\/hr on NG. Fuel supply, piping, and regulator sizing must be designed for the generator's full-load demand.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFortress™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e076850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid-Cooled Automatic Standby Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSI 4.3L V6 industrial powertrain, liquid-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Horsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 hp LP \/ 78 hp NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Propane Vapor \/ Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e337,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e328,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess Than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Operating Sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91\" L x 39.4\" W x 41\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,634 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomotive-grade galvanneal aluminum, powder-coat finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo – sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2200 \/ CSA C22.2 No. 100-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-Year Limited Warranty (Parts, Labor \u0026amp; Travel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the Briggs \u0026amp; Stratton 076850 include a transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. The 076850 is a generator-only package. A compatible Briggs \u0026amp; Stratton automatic transfer switch, sized for the property's electrical service, is required for automatic operation.\u003c\/p\u003e\n\u003ch3\u003eCan a 48kW generator power an entire house?\u003c\/h3\u003e\n\u003cp\u003eFor many large homes, yes. A 48kW unit has substantially more capacity than air-cooled standby generators, but whole-home coverage still depends on the total running and starting load. Homes with several HVAC systems, electric heat, or EV chargers may still need load management.\u003c\/p\u003e\n\u003ch3\u003eWhat is the output on natural gas vs. propane?\u003c\/h3\u003e\n\u003cp\u003eThe 076850 is rated 48kW on LP and 45kW on NG.\u003c\/p\u003e\n\u003ch3\u003eHow much fuel does it use?\u003c\/h3\u003e\n\u003cp\u003eEstimated consumption at 50% load is about 337,000 BTU\/hr on LP and 328,000 BTU\/hr on NG. Actual use varies with load, elevation, and cycling appliances.\u003c\/p\u003e\n\u003ch3\u003eHow loud is it?\u003c\/h3\u003e\n\u003cp\u003eBriggs \u0026amp; Stratton lists a normal operating sound level of about 68 dBA. Perceived sound depends on placement, distance, and surrounding structures.\u003c\/p\u003e\n\u003ch3\u003eIs this generator suitable for a small business?\u003c\/h3\u003e\n\u003cp\u003eYes. The Fortress 48kW is marketed for large residences and small-business applications on 120\/240V single-phase service. For three-phase service, a three-phase commercial model is required.\u003c\/p\u003e\n\u003ch3\u003eHow is it delivered?\u003c\/h3\u003e\n\u003cp\u003eAt 1,634 lbs assembled, this unit ships by freight and typically requires a loading dock, forklift, or crane for offloading. Plan site access and a concrete pad in advance.\u003c\/p\u003e\n\u003ch2\u003eShop Briggs \u0026amp; Stratton Fortress Generators at AC Units For Less\u003c\/h2\u003e\n\u003cp\u003ePower large homes and small businesses with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076850 48kW Fortress Liquid-Cooled Standby Generator\u003c\/strong\u003e. Shop Briggs \u0026amp; Stratton standby generators, automatic transfer switches, Symphony II power-management modules, and generator accessories at AC Units For Less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Generator sizing, transfer-switch selection, fuel-system capacity, pad and placement, and installation should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions, NFPA 37, and applicable electrical, fuel-gas, and building codes.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":56072894611747,"sku":"076850","price":23236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/48kWBriggs_StrattonFortressLiquid-CooledStandbyGenerator-120240V_DualFuel_LPNG_200ABreaker_6-YearWarranty-Model076850.png?v=1794722245"},{"product_id":"briggs-stratton-60kw-fortress-liquid-cooled-standby-generator-076860","title":"60kW Briggs \u0026 Stratton Fortress Liquid-Cooled Standby Generator - 120\/240V, Dual Fuel (LP\/NG), 250A Breaker, 6-Year Warranty - Model 076860","description":"\u003cp\u003e\u003cstrong\u003eModel Number: 076860\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGet commercial-grade backup power for larger properties with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076860 60kW Fortress™ Liquid-Cooled Standby Generator\u003c\/strong\u003e. Built for very large homes, estates, and small-to-medium businesses, the Fortress 60kW delivers \u003cstrong\u003e60kW on LP \/ 55kW on NG\u003c\/strong\u003e at 120\/240V single-phase, giving you the capacity to keep HVAC, pumps, kitchens, and whole-home loads running through an extended outage.\u003c\/p\u003e\n\u003cp\u003eAt its core is a \u003cstrong\u003ePSI 5.7L V8 industrial powertrain, liquid-cooled\u003c\/strong\u003e engine running at a low 1,800 RPM — half the speed of typical air-cooled standby units — for quieter, more fuel-efficient operation and longer engine life. A \u003cstrong\u003e250A\u003c\/strong\u003e main breaker, low-THD alternator, and corrosion-resistant enclosure round out a system designed for years of outdoor service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This is a generator-only package. An automatic transfer switch (sold separately) is required for automatic operation.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60kW Liquid-Cooled Standby Power:\u003c\/strong\u003e Rated 60kW on LP \/ 55kW on NG for large residential and light-commercial loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Fuel (LP \/ NG):\u003c\/strong\u003e Runs on liquid propane vapor or natural gas, based on the fuel available at the site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid-Cooled Industrial Engine:\u003c\/strong\u003e PSI 5.7L V8 industrial powertrain, liquid-cooled at 1,800 RPM, built for extended run times.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250A Main Breaker:\u003c\/strong\u003e Integrated generator breaker sized for the unit's rated output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240V Single-Phase Output:\u003c\/strong\u003e Matches standard residential and light-commercial single-phase service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess Than 5% THD:\u003c\/strong\u003e Clean, stable power for electronics, HVAC controls, and appliance control boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Standby Operation:\u003c\/strong\u003e Starts within seconds of an outage when paired with a compatible Briggs \u0026amp; Stratton automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymphony® II Power Management Compatible:\u003c\/strong\u003e Works with Symphony II load management to prioritize high-wattage appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfoHub™ \/ EnergyTrak™ Monitoring Ready:\u003c\/strong\u003e Supports Briggs \u0026amp; Stratton remote monitoring (subscription may be required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Outdoor Enclosure:\u003c\/strong\u003e Automotive-grade galvanneal aluminum, powder-coat finish.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Designed for ambient temperatures from approximately -20°F to 104°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2200 \/ CSA Rated:\u003c\/strong\u003e Rated in accordance with UL 2200 and CSA C22.2 No. 100-14.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6-Year Limited Warranty (Parts, Labor \u0026amp; Travel):\u003c\/strong\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage. See manufacturer terms for details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose a Liquid-Cooled Generator?\u003c\/h2\u003e\n\u003cp\u003eAir-cooled home standby generators top out in the mid-20kW range. When a property's demand goes beyond that — multiple HVAC systems, electric heat, pool equipment, well pumps, a shop, or a small business — a liquid-cooled generator is the next step.\u003c\/p\u003e\n\u003cp\u003eLiquid cooling keeps engine temperatures stable under sustained heavy load, which makes the Fortress series better suited to long outages and high-demand properties than air-cooled units.\u003c\/p\u003e\n\u003ch2\u003e60kW of Backup Power for Large Properties\u003c\/h2\u003e\n\u003cp\u003eDepending on the property's total electrical demand, a properly configured 60kW standby system may support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple central air-conditioning or heat-pump systems\u003c\/li\u003e\n\u003cli\u003eElectric water heaters and ranges\u003c\/li\u003e\n\u003cli\u003eWell, sump, and pool pumps\u003c\/li\u003e\n\u003cli\u003eRefrigeration and freezers\u003c\/li\u003e\n\u003cli\u003eLighting, networking, and security systems\u003c\/li\u003e\n\u003cli\u003eDetached garages, workshops, and outbuildings\u003c\/li\u003e\n\u003cli\u003eSmall-business equipment, POS, and office loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual capacity depends on the combined running and starting requirements of all equipment operating at the same time. A professional load calculation should be used for sizing.\u003c\/p\u003e\n\u003ch2\u003eNatural Gas or Liquid Propane\u003c\/h2\u003e\n\u003cp\u003eThe Fortress 60kW produces 60kW on liquid propane and 55kW on natural gas. Size the system using the rating for the fuel you plan to use.\u003c\/p\u003e\n\u003cp\u003eEstimated fuel use at 50% load is about 644,000 BTU\/hr on LP and 561,000 BTU\/hr on NG. Fuel supply, piping, and regulator sizing must be designed for the generator's full-load demand.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFortress™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e076860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid-Cooled Automatic Standby Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250A LP \/ 229A NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSI 5.7L V8 industrial powertrain, liquid-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Horsepower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 hp LP \/ 104 hp NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Propane Vapor \/ Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e644,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Use @ 50% Load – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e561,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess Than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Operating Sound\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98\" L x 39.4\" W x 43\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembled Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,020 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomotive-grade galvanneal aluminum, powder-coat finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo – sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2200 \/ CSA C22.2 No. 100-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-Year Limited Warranty (Parts, Labor \u0026amp; Travel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the Briggs \u0026amp; Stratton 076860 include a transfer switch?\u003c\/h3\u003e\n\u003cp\u003eNo. The 076860 is a generator-only package. A compatible Briggs \u0026amp; Stratton automatic transfer switch, sized for the property's electrical service, is required for automatic operation.\u003c\/p\u003e\n\u003ch3\u003eCan a 60kW generator power an entire house?\u003c\/h3\u003e\n\u003cp\u003eFor many large homes, yes. A 60kW unit has substantially more capacity than air-cooled standby generators, but whole-home coverage still depends on the total running and starting load. Homes with several HVAC systems, electric heat, or EV chargers may still need load management.\u003c\/p\u003e\n\u003ch3\u003eWhat is the output on natural gas vs. propane?\u003c\/h3\u003e\n\u003cp\u003eThe 076860 is rated 60kW on LP and 55kW on NG.\u003c\/p\u003e\n\u003ch3\u003eHow much fuel does it use?\u003c\/h3\u003e\n\u003cp\u003eEstimated consumption at 50% load is about 644,000 BTU\/hr on LP and 561,000 BTU\/hr on NG. Actual use varies with load, elevation, and cycling appliances.\u003c\/p\u003e\n\u003ch3\u003eHow loud is it?\u003c\/h3\u003e\n\u003cp\u003eBriggs \u0026amp; Stratton lists a normal operating sound level of about 70 dBA. Perceived sound depends on placement, distance, and surrounding structures.\u003c\/p\u003e\n\u003ch3\u003eIs this generator suitable for a small business?\u003c\/h3\u003e\n\u003cp\u003eYes. The Fortress 60kW is marketed for large residences and small-business applications on 120\/240V single-phase service. For three-phase service, a three-phase commercial model is required.\u003c\/p\u003e\n\u003ch3\u003eHow is it delivered?\u003c\/h3\u003e\n\u003cp\u003eAt 2,020 lbs assembled, this unit ships by freight and typically requires a loading dock, forklift, or crane for offloading. Plan site access and a concrete pad in advance.\u003c\/p\u003e\n\u003ch2\u003eShop Briggs \u0026amp; Stratton Fortress Generators at AC Units For Less\u003c\/h2\u003e\n\u003cp\u003ePower large homes and small businesses with the \u003cstrong\u003eBriggs \u0026amp; Stratton 076860 60kW Fortress Liquid-Cooled Standby Generator\u003c\/strong\u003e. Shop Briggs \u0026amp; Stratton standby generators, automatic transfer switches, Symphony II power-management modules, and generator accessories at AC Units For Less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Generator sizing, transfer-switch selection, fuel-system capacity, pad and placement, and installation should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions, NFPA 37, and applicable electrical, fuel-gas, and building codes.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":56072894644515,"sku":"076860","price":27277.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/076860.png?v=1794722181"},{"product_id":"briggs-stratton-040816-26kw-standby-generator","title":"Briggs \u0026 Stratton 040816 26kW PowerProtect+ Generator with 200A SE Transfer Switch","description":"\u003cp\u003e\u003cstrong\u003eModel Number: 040816\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProtect larger homes with the \u003cstrong\u003eBriggs \u0026amp; Stratton 040816 26kW PowerProtect+™ Standby Generator with 200 Amp Service Entrance Transfer Switch\u003c\/strong\u003e. This package pairs the most powerful air-cooled generator in the PowerProtect line with a \u003cstrong\u003e200 Amp service-entrance-rated automatic transfer switch\u003c\/strong\u003e for a streamlined whole-home installation.\u003c\/p\u003e\n\u003cp\u003eThe PowerProtect+ 26kW delivers \u003cstrong\u003e26kW on LP and 24kW on natural gas with NGMax™ technology\u003c\/strong\u003e at 120\/240V single-phase. It is powered by a \u003cstrong\u003eBriggs \u0026amp; Stratton Vanguard® 993cc V-Twin engine\u003c\/strong\u003e and offers up to 65.5 kVA of motor-starting capability for large loads such as central air conditioning.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e26kW Standby Power:\u003c\/strong\u003e 26kW on LP \/ 24kW on NG with NGMax technology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 Amp SE Transfer Switch Included:\u003c\/strong\u003e Service-entrance-rated automatic transfer switch for compatible 200A residential services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240V Single-Phase Output:\u003c\/strong\u003e Designed for standard residential electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVanguard® V-Twin Engine:\u003c\/strong\u003e 993cc commercial-grade OHV engine with low-oil shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e65.5 kVA Motor-Starting Capability:\u003c\/strong\u003e Helps start demanding motor loads such as central AC compressors and well pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNatural Gas or Liquid Propane:\u003c\/strong\u003e Dual-fuel capability based on the home's available fuel source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess Than 5% THD:\u003c\/strong\u003e Clean, stable power for modern electronics and appliances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-Facing Exhaust:\u003c\/strong\u003e PowerProtect+ design directs exhaust away from the home.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergyTrak™ Monitoring:\u003c\/strong\u003e Remote generator monitoring (subscription may be required).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymphony® II and Amplify™ Compatible:\u003c\/strong\u003e Supports Briggs \u0026amp; Stratton power-management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Residential Operation:\u003c\/strong\u003e Approximately 63 dBA at low idle and 65 dBA during normal operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Enclosure, 186 MPH Wind Rating:\u003c\/strong\u003e Corrosion-resistant enclosure for year-round outdoor installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature Range:\u003c\/strong\u003e Designed for approximately -20°F to 104°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Year Limited Warranty:\u003c\/strong\u003e Parts, labor, and travel coverage. See manufacturer terms for details.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutomatic Backup Power When the Utility Goes Down\u003c\/h2\u003e\n\u003cp\u003eWhen utility power is interrupted, the included 200 Amp automatic transfer switch detects the outage and signals the generator to start. Once the generator is ready, the switch transfers the home's electrical system to generator power, then returns it to utility power when service is restored — even when no one is home.\u003c\/p\u003e\n\u003ch2\u003e200 Amp Service Entrance Transfer Switch Included\u003c\/h2\u003e\n\u003cp\u003eA service-entrance-rated transfer switch can be installed at the meter as the home's main disconnect, making whole-home backup straightforward on compatible 200A services.\u003c\/p\u003e\n\u003cp\u003eA 200 Amp transfer switch does not mean the generator can supply 200 amps at once. Total load must remain within the generator's 26kW (LP) \/ 24kW (NG) rating; load management may be needed for homes with large demands.\u003c\/p\u003e\n\u003ch2\u003eSized for Larger Homes and HVAC Loads\u003c\/h2\u003e\n\u003cp\u003eDepending on total demand, a properly configured 26kW system may support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCentral air conditioning and heat pumps\u003c\/li\u003e\n\u003cli\u003eHeating equipment\u003c\/li\u003e\n\u003cli\u003eRefrigerators and freezers\u003c\/li\u003e\n\u003cli\u003eWell and sump pumps\u003c\/li\u003e\n\u003cli\u003eLighting, networking, and security systems\u003c\/li\u003e\n\u003cli\u003eKitchen appliances\u003c\/li\u003e\n\u003cli\u003eSelected high-demand appliances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGenerator sizing should be based on the actual running and starting requirements of the connected equipment, not HVAC tonnage alone.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerProtect+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e040816\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Home Standby Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – LP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output – NG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton Vanguard 993cc V-Twin OHV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor-Starting Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 65.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess Than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eService Entrance Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Level – Low Idle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Level – Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCorrosion-Resistant Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWind Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 186 mph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°F to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL \/ cUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-Year Limited Warranty (Parts, Labor \u0026amp; Travel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes the Briggs \u0026amp; Stratton 040816 include a transfer switch?\u003c\/h3\u003e\n\u003cp\u003eYes. It includes a 200 Amp service entrance rated automatic transfer switch.\u003c\/p\u003e\n\u003ch3\u003eWhat is the output on natural gas vs. propane?\u003c\/h3\u003e\n\u003cp\u003e26kW on liquid propane and 24kW on natural gas with NGMax technology.\u003c\/p\u003e\n\u003ch3\u003eCan a 26kW generator power an entire house?\u003c\/h3\u003e\n\u003cp\u003eMany larger homes, yes — but it depends on total demand. Homes with multiple HVAC systems, electric heat, or other heavy loads may need load management.\u003c\/p\u003e\n\u003ch3\u003eCan this generator run central air conditioning?\u003c\/h3\u003e\n\u003cp\u003ePotentially, yes. Up to 65.5 kVA of motor-starting capability helps with compressor starts; actual compatibility depends on the HVAC equipment's starting and running requirements.\u003c\/p\u003e\n\u003ch3\u003eHow loud is the Briggs \u0026amp; Stratton 26kW generator?\u003c\/h3\u003e\n\u003cp\u003eAbout 63 dBA at low idle and 65 dBA during normal operation, per manufacturer specifications.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between 040816 and 040814?\u003c\/h3\u003e\n\u003cp\u003eThe 040816 includes a single 200A SE transfer switch. The 040814 includes dual 200A SE transfer switches for 400A or multi-panel services.\u003c\/p\u003e\n\u003ch2\u003eShop Briggs \u0026amp; Stratton PowerProtect Generators at AC Units For Less\u003c\/h2\u003e\n\u003cp\u003eCombine 26kW of standby capacity, a Vanguard V-Twin engine, dual-fuel operation, and an included 200 Amp SE transfer switch with the \u003cstrong\u003eBriggs \u0026amp; Stratton 040816 26kW PowerProtect+ package\u003c\/strong\u003e. Shop Briggs \u0026amp; Stratton generators, transfer switches, and power-management equipment at AC Units For Less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Generator sizing, HVAC compatibility, fuel-system capacity, electrical loads, transfer-switch configuration, and installation requirements should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions and applicable electrical, fuel-gas, and building codes.\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":56072894677283,"sku":"040816","price":8069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Briggs_Stratton04081626kWPowerProtect_Generatorwith200ASETransferSwitch.webp?v=1794722083"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/collections\/Briggs-Stratton-Generators-Large-Homes-category.webp?v=1793195836","url":"https:\/\/www.acunitsforless.com\/es\/collections\/briggs-stratton-generator-large-homes.oembed","provider":"acunitsforless.com","version":"1.0","type":"link"}