{"title":"Voltas Central Ducted HVAC Systems","description":"\u003cp\u003eShop Voltas Central Ducted HVAC Systems for heating and cooling applications that distribute conditioned air through a network of ducts. These systems can be suitable for homes, commercial spaces, and other properties where centralized temperature control is preferred. Explore available models and compare cooling capacities, system configurations, and installation requirements to find equipment that fits your building and HVAC project.\u003c\/p\u003e","products":[{"product_id":"voltas-2-ton-central-heat-pump-complete-system-208-230v-r-454b-seer2-20-hspf2-10-vauwr-24hcdr2","title":"Voltas 2 Ton Central Heat Pump Complete System 208-230V R-454B SEER2 20 HSPF2 10 | VAUWR-24HCDR2 VAUH-24HCDR2","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Voltas VAUWR-24HCDR2 is a 2-ton (24,000 BTU) whole-home ducted heat pump system engineered for North American residential applications. Paired with the Voltas Premium Air Handler, this complete system delivers year-round heating and cooling through your existing ductwork — no separate furnace required. Backed by Voltas, India's #1 AC brand and a Tata Group company with over 70 years of HVAC engineering expertise, the VAUWR-24HCDR2 is purpose-built for the climatic demands of US and Canadian homes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eWith SEER2 20 cooling efficiency and a class-leading HSPF2 10 heating efficiency rating, this system reduces energy consumption without sacrificing comfort. A wide operational range — cooling from 5°F to 125°F ambient, heating from -13°F to 75°F — means reliable performance even through harsh winters.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTwin Rotary Inverter Compressor\u003c\/strong\u003e\u003cbr\u003eThe outdoor unit runs a twin rotary inverter compressor with variable-speed operation that continuously modulates output to match the home's actual load. The result is more precise temperature control, less on\/off cycling, and significantly lower energy consumption compared to single-stage systems.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eR-454B Eco-Friendly Refrigerant\u003c\/strong\u003e\u003cbr\u003eThe VAUWR series runs on R-454B, a next-generation low-GWP refrigerant with a global warming potential approximately 78% lower than the R-410A it replaces. The system includes an integrated A2L leak detection sensor in the air handler for early detection and code compliance.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTXV Expansion Valve\u003c\/strong\u003e\u003cbr\u003eA thermostatic expansion valve (TXV) provides precise refrigerant metering across a wide range of operating conditions — improving system efficiency and protecting the compressor at both high and low ambient temperatures.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBase Pan Heater\u003c\/strong\u003e\u003cbr\u003eThe outdoor unit includes an integrated base pan heater that prevents ice accumulation in the drain pan during cold-weather heating operation, ensuring uninterrupted performance and proper condensate drainage through freezing temperatures.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eVariable-Speed DC Fan\u003c\/strong\u003e\u003cbr\u003eThe outdoor unit's variable-speed DC condenser fan adjusts airflow continuously in response to load and ambient conditions, delivering quieter operation and better efficiency than fixed-speed alternatives.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpace-Saving Side Discharge Design\u003c\/strong\u003e\u003cbr\u003eThe compact side-discharge configuration provides installation flexibility in tight spaces — particularly useful for townhomes, urban lots, or installations with limited clearance on the discharge side.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ePremium Air Handler — ECM Motor\u003c\/strong\u003e\u003cbr\u003eThe Voltas Premium Air Handler uses an Electronically Commutated Motor (ECM) that operates at a fraction of the energy draw of standard PSC motors. The ECM adjusts airflow in real time to match system demand, reducing electricity consumption and operating noise.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eEnhanced Anti-Corrosion Coils\u003c\/strong\u003e\u003cbr\u003eThe air handler's indoor coil features a specialized anti-corrosion coating engineered to withstand challenging indoor environments, extending coil life and maintaining heat transfer efficiency over the system's service life.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSmart System Compatibility\u003c\/strong\u003e\u003cbr\u003eThe air handler is compatible with standard 24V thermostats, including Wi-Fi-enabled smart thermostats, enabling remote temperature scheduling, monitoring, and energy reporting from any connected device.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eMulti-Position Air Handler Installation\u003c\/strong\u003e\u003cbr\u003eThe Voltas Premium Air Handler supports horizontal and vertical installation orientations, accommodating attic, closet, utility room, or crawl space installations across a wide range of home configurations.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eLong Piping Flexibility\u003c\/strong\u003e\u003cbr\u003eWith a maximum refrigerant pipe run of 131 feet and a maximum height difference of 98 feet between the indoor and outdoor units, the VAUWR-24HCDR2 accommodates complex installation layouts in larger homes and multi-story structures.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eVAUWR-24HCDR2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10,500–33,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e24,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e11,700–37,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Heating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e20,800 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThrottle Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208–230V \/ 1Ph \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThermostat\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStandard 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTwin Rotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5°F – 125°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-13°F – 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e131 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e98 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Dimensions (W×H×D)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e900 × 750 × 340 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e116.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Voltas","offers":[{"title":"Default Title","offer_id":55249129505059,"sku":"VAUWR-24HCDR2 VAUH-24HCDR2","price":3457.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/CentralHeatPumpCompleteSystem_5dfde263-19fb-4f8b-96e9-e543b2297ebc.png?v=1781763021"},{"product_id":"voltas-3-ton-central-heat-pump-complete-system-208-230v-r-454b-seer2-19-5-hspf2-10-5-vauwr-36hcdr2-vauh-36hcdr2","title":"Voltas 3 Ton Central Heat Pump Complete System 208-230V R-454B SEER2 19.5 HSPF2 10.5 | VAUWR-36HCDR2 VAUH-36HCDR2","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Voltas VAUWR-36HCDR2 is a 3-ton (36,000 BTU) whole-home ducted heat pump system built for larger residences and open-plan living spaces. Paired with the Voltas Premium Air Handler, this complete system replaces both the air conditioner and furnace in a single efficient package — distributing conditioned air through existing ductwork with no fuel combustion required. Engineered to North American standards by Voltas, a Tata Group company and India's #1 AC brand, the VAUWR-36HCDR2 is rated SEER2 19.5 and leads the lineup in heating efficiency at HSPF2 10.5 — the highest rating in the VAUWR series.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eA maximum heating output of 31,000 BTU at 5°F outdoor ambient gives this unit exceptional cold-climate heating capability, maintaining comfort well below freezing without auxiliary electric heat in most applications.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTwin Rotary Inverter Compressor\u003c\/strong\u003e\u003cbr\u003eThe twin rotary inverter compressor continuously modulates capacity from 22,000 to 41,000 BTU in cooling and 12,600 to 54,000 BTU in heating — an unusually wide modulation range that keeps the system running at peak efficiency under both peak-load and mild-weather conditions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eR-454B Eco-Friendly Refrigerant\u003c\/strong\u003e\u003cbr\u003eR-454B provides a global warming potential approximately 78% lower than R-410A while maintaining equivalent system performance. The integrated A2L leak detection sensor in the air handler ensures early detection and compliance with evolving refrigerant safety codes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTXV Expansion Valve\u003c\/strong\u003e\u003cbr\u003ePrecise thermostatic expansion valve control optimizes refrigerant flow across the full capacity range, protecting the compressor and maximizing efficiency at both high ambient cooling conditions and low ambient heating conditions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBase Pan Heater\u003c\/strong\u003e\u003cbr\u003eThe integrated base pan heater prevents ice accumulation in the outdoor unit drain pan during sustained cold-weather heating cycles, maintaining reliable drainage and protecting against ice damage to the unit base.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eVariable-Speed DC Condenser Fan\u003c\/strong\u003e\u003cbr\u003eThe variable-speed DC fan on the outdoor unit adjusts airflow continuously in response to real-time load conditions, reducing energy draw and noise during partial-load operation — which represents the majority of annual operating hours.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpace-Saving Side Discharge Design\u003c\/strong\u003e\u003cbr\u003eThe 3-ton outdoor unit's compact side-discharge design provides installation flexibility in constrained outdoor spaces, with a footprint of 1,100 × 875 × 450 mm that suits most residential equipment pads and wall-mount brackets.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ePremium Air Handler — ECM Motor\u003c\/strong\u003e\u003cbr\u003eThe Voltas Premium Air Handler's ECM motor automatically adjusts blower speed to match system airflow requirements, maintaining proper static pressure across a range of duct configurations and filter conditions — quietly and efficiently.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eEnhanced Anti-Corrosion Coils\u003c\/strong\u003e\u003cbr\u003eSpecially coated indoor coils resist corrosion from humidity, airborne contaminants, and coastal environments, extending coil life and maintaining heat transfer performance over the full service life of the system.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSmart System Compatibility\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat compatibility makes the VAUWR-36HCDR2 a straightforward drop-in replacement for existing ducted systems, while full compatibility with Wi-Fi smart thermostats enables scheduling, remote access, and energy tracking.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eLong Piping Flexibility\u003c\/strong\u003e\u003cbr\u003eMaximum refrigerant pipe length of 147 feet and up to 98 feet of vertical height difference between the indoor and outdoor units accommodates complex routing in larger two-story homes and multi-story installations.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eVAUWR-36HCDR2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e36,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e22,000–41,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e34,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e12,600–54,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Heating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e31,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e19.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThrottle Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208–230V \/ 1Ph \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThermostat\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStandard 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTwin Rotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5°F – 125°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-13°F – 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e147 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e98 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Dimensions (W×H×D)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e1,100 × 875 × 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e185.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Voltas","offers":[{"title":"Default Title","offer_id":55249142055203,"sku":"VAUWR-36HCDR2 VAUH-36HCDR2","price":4346.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/CentralHeatPumpCompleteSystem_9362ca43-b375-46e4-b868-bfb1cf7df853.png?v=1781763004"},{"product_id":"voltas-4-ton-central-heat-pump-complete-system-208-230v-r-454b-seer2-19-hspf2-9-vauwr-48hcdr2-vauh-48hcdr2","title":"Voltas 4 Ton Central Heat Pump Complete System 208-230V R-454B SEER2 19 HSPF2 9 | VAUWR-48HCDR2 VAUH-48HCDR2","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Voltas VAUWR-48HCDR2 is a 4-ton (48,000 BTU) whole-home ducted heat pump system designed for larger single-family homes, multi-zone residential applications, and light commercial spaces requiring substantial conditioning capacity. Paired with the Voltas Premium Air Handler, this complete system handles both heating and cooling through existing ductwork — delivering SEER2 19 cooling and HSPF2 9 heating efficiency at a capacity tier where most competing systems sacrifice efficiency for output.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eMaximum heating capacity reaches 37,000 BTU at 5°F outdoor ambient, providing robust cold-weather heating in climates that regularly see sub-freezing temperatures. The twin rotary inverter compressor modulates from 22,000 to 58,000 BTU in cooling and 19,800 to 52,000 BTU in heating — a wide enough range to handle both mild spring days and peak summer loads without cycling.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTwin Rotary Inverter Compressor\u003c\/strong\u003e\u003cbr\u003eThe twin rotary design eliminates the vibrational imbalance inherent to single-piston rotary compressors, operating more quietly and reliably at low-speed modulated conditions — which represent the vast majority of annual runtime hours in most climates.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eR-454B Eco-Friendly Refrigerant\u003c\/strong\u003e\u003cbr\u003eR-454B delivers a GWP approximately 78% lower than R-410A with no performance trade-off at 4-ton capacity. The system's A2L leak detection sensor in the air handler provides early warning capability and supports compliance with evolving building codes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTXV Expansion Valve\u003c\/strong\u003e\u003cbr\u003eThermostatic expansion valve control maintains precise refrigerant superheat across the full modulation range, protecting compressor reliability and optimizing efficiency at both high-ambient cooling and low-ambient heating conditions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBase Pan Heater\u003c\/strong\u003e\u003cbr\u003eThe outdoor unit base pan heater prevents ice accumulation during extended cold-weather heating cycles, ensuring reliable condensate drainage and protecting the unit base from freeze damage in climates with sustained sub-freezing temperatures.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eVariable-Speed DC Condenser Fan\u003c\/strong\u003e\u003cbr\u003eContinuous variable-speed fan control on the outdoor unit matches condenser airflow to real-time system demand, reducing electrical draw and noise during the partial-load operation that dominates most climates' annual runtime.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpace-Saving Side Discharge Design\u003c\/strong\u003e\u003cbr\u003eThe 4-ton outdoor unit uses a vertical tower configuration (975 × 1,460 × 330 mm) with side discharge, providing a compact footprint relative to its capacity and enabling installation in spaces with limited clearance at the discharge face.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ePremium Air Handler — ECM Motor\u003c\/strong\u003e\u003cbr\u003eAt 4-ton capacity, the ECM motor's ability to maintain proper airflow at varying static pressures becomes especially important — particularly in duct systems with higher resistance from longer runs, additional zones, or denser filtration. The ECM adjusts automatically, maintaining design airflow without the contractor having to re-tap motor windings.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eEnhanced Anti-Corrosion Coils\u003c\/strong\u003e\u003cbr\u003eAnti-corrosion coated indoor coil surfaces resist degradation in high-humidity environments, maintaining heat transfer efficiency and system capacity over the life of the system.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSmart System \u0026amp; Multi-Position Installation\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat compatibility with Wi-Fi smart thermostat support. Air handler supports horizontal and vertical installation for attic, utility closet, or mechanical room applications.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eLong Piping Flexibility\u003c\/strong\u003e\u003cbr\u003eMaximum pipe run of 246 feet and 98-foot height differential between indoor and outdoor units accommodates challenging installation layouts in larger homes, commercial buildings, and multi-story structures.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eVAUWR-48HCDR2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e48,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e22,000–58,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e48,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e19,800–52,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Heating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e37,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThrottle Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208–230V \/ 1Ph \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThermostat\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStandard 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTwin Rotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5°F – 125°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-13°F – 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e98 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Dimensions (W×H×D)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e975 × 1,460 × 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e244.7 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Voltas","offers":[{"title":"Default Title","offer_id":55249143660835,"sku":"VAUWR-48HCDR2 VAUH-48HCDR2","price":5940.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/CentralHeatPumpCompleteSystem_d945122a-24b3-4a07-8a7f-2143b2b3da76.png?v=1781762987"},{"product_id":"voltas-5-ton-central-heat-pump-complete-system-208-230v-r454b-vauwr-60hcdr2","title":"Voltas 5 Ton Central Heat Pump Complete System 208-230V R-454B SEER2 19 HSPF2 9 | VAUWR-60HCDR2 VAUH-60HCDR2","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe Voltas VAUWR-60HCDR2 is the top-capacity model in the VAUWR whole-home ducted heat pump lineup — a 5-ton (57,000 BTU rated) system built for large single-family homes, multi-zone residential applications, and light commercial installations requiring maximum output in a single-phase configuration. Paired with the Voltas Premium Air Handler, this complete system delivers SEER2 19 cooling and HSPF2 9 heating efficiency across a capacity range that reaches 63,500 BTU peak cooling and 60,000 BTU peak heating.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eMaximum heating output at 5°F outdoor ambient is 42,000 BTU — the highest in the series — providing meaningful cold-climate heating capacity without auxiliary heat in most US residential applications. The twin rotary inverter compressor modulates from 22,000 to 63,500 BTU in cooling and 20,000 to 60,000 BTU in heating, covering everything from mild overnight setback conditions to peak summer and winter demand.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTwin Rotary Inverter Compressor\u003c\/strong\u003e\u003cbr\u003eThe twin rotary inverter compressor provides the smooth, vibration-reduced operation needed at 5-ton capacity for quiet performance and long-term reliability. Continuous modulation eliminates the efficiency losses and temperature swings associated with fixed-stage compressors in oversized applications.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eR-454B Eco-Friendly Refrigerant\u003c\/strong\u003e\u003cbr\u003eThe VAUWR-60HCDR2 runs on R-454B — a low-GWP A2L refrigerant with approximately 78% lower climate impact than R-410A. The Voltas Premium Air Handler includes an integrated A2L leak detection sensor for early detection and ongoing compliance with current and emerging refrigerant codes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eTXV Expansion Valve\u003c\/strong\u003e\u003cbr\u003eThermostatic expansion valve control delivers precise refrigerant metering across the full capacity range — from low-load winter heating to peak-demand summer cooling — protecting the compressor and maintaining system efficiency throughout.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eBase Pan Heater\u003c\/strong\u003e\u003cbr\u003eThe outdoor unit's base pan heater prevents ice buildup in the condensate drain pan during cold-weather heating cycles, maintaining proper drainage and unit integrity through sustained sub-freezing ambient temperatures.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eVariable-Speed DC Condenser Fan\u003c\/strong\u003e\u003cbr\u003eThe variable-speed DC outdoor fan continuously modulates airflow in response to system demand and ambient conditions. At 5-ton capacity, this capability is particularly valuable — reducing noise and energy draw during the partial-load operation that represents most of the system's annual runtime.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpace-Saving Side Discharge Design\u003c\/strong\u003e\u003cbr\u003eThe VAUWR-60HCDR2 shares the vertical tower form factor with the 4-ton model (975 × 1,460 × 330 mm), maintaining the same compact footprint despite the step up in capacity. Side discharge orientation enables installation in spaces where front-discharge units would require additional clearance.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003ePremium Air Handler — ECM Motor\u003c\/strong\u003e\u003cbr\u003eThe ECM blower motor in the Voltas Premium Air Handler is essential at 5-ton capacity, where proper airflow at design static pressure is critical to system performance and coil protection. The ECM maintains target airflow automatically across a range of duct system conditions, filter loading states, and operating modes.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eEnhanced Anti-Corrosion Coils\u003c\/strong\u003e\u003cbr\u003eCorrosion-resistant coated indoor coil surfaces maintain heat transfer efficiency across the full service life of the system — particularly important at larger capacities where coil replacement costs are substantially higher.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSmart System \u0026amp; Multi-Position Installation\u003c\/strong\u003e\u003cbr\u003eCompatible with standard 24V thermostats and Wi-Fi-enabled smart thermostats. Air handler supports multiple installation orientations for flexible placement in mechanical rooms, attics, and utility spaces.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eLong Piping Flexibility\u003c\/strong\u003e\u003cbr\u003eMaximum refrigerant pipe run of 246 feet with up to 98 feet of height differential between units supports complex installation layouts in large homes, commercial buildings, and applications where significant distance between the indoor and outdoor units is unavoidable.\u003c\/p\u003e\n\u003chr class=\"border-border-200 border-t-0.5 my-3 mx-1.5\"\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eVAUWR-60HCDR2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e57,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e22,000–63,500 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Rated)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e56,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Capacity (Min–Max)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e19,800–60,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Heating Capacity @ 5°F\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e42,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSEER2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eR-454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThrottle Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTXV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e208–230V \/ 1Ph \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eThermostat\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStandard 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eTwin Rotary Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCooling Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e5°F – 125°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eHeating Operation Range\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e-13°F – 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Pipe Length\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e246 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eMax Height Difference\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e98 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Dimensions (W×H×D)\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e975 × 1,460 × 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOutdoor Unit Weight\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e244.7 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Voltas","offers":[{"title":"Default Title","offer_id":55249145495843,"sku":"VAUWR-60HCDR2 VAUH-60HCDR2","price":5940.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/CentralHeatPumpCompleteSystem_079204f4-fc9a-441c-97c1-854e4533a5dc.png?v=1781762965"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/collections\/central_duct_voltas_category.webp?v=1792786031","url":"https:\/\/www.acunitsforless.com\/collections\/voltas-central-ducted-hvac-systems.oembed","provider":"acunitsforless.com","version":"1.0","type":"link"}