{"title":"Goodman R-32 Heat Pump Systems","description":"\u003cp\u003eComplete, AHRI-matched Goodman split heat pump systems: an \u003cstrong\u003eR-32 outdoor heat pump\u003c\/strong\u003e paired with a matched \u003cstrong\u003eGoodman air handler\u003c\/strong\u003e. Each listing covers one size. Choose your air handler and an optional HKTSN electric heat kit on the product page, and the price updates with your selection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot sure what size you need?\u003c\/strong\u003e Try our \u003ca href=\"\/pages\/sizing-estimator-for-heating-cooling-equipment\"\u003eSizing Estimator\u003c\/a\u003e or call \u003ca href=\"tel:6785357176\"\u003e678-535-7176\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhich Goodman series is right for you?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eBest for\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLZS4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-stage, about 14.5–15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position, 9-speed ECM\u003c\/td\u003e\n\u003ctd\u003eMild climates and the best value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLZS5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-stage, up to 8.2 HSPF2 heating efficiency\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position, 9-speed ECM\u003c\/td\u003e\n\u003ctd\u003eHomes with real winters, where the heat pump does most of the heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLZT7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, 16.2–17.5 SEER2\u003c\/td\u003e\n\u003ctd\u003eAMVT variable-speed, communicating-capable\u003c\/td\u003e\n\u003ctd\u003eQuieter, steadier comfort and better humidity control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat every system includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003eAHRI-matched Goodman air handler with factory-installed TXV, multi-position (upflow or horizontal; downflow with kit where required)\u003c\/li\u003e\n\u003cli\u003eOptional 5, 8, or 10 kW HKTSN heat kit for backup heat\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty with online registration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSize guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eTypical home size*\u003c\/th\u003e\n\u003cth\u003eSeries available\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5 ton\u003c\/td\u003e\n\u003ctd\u003e750–900 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 ton\u003c\/td\u003e\n\u003ctd\u003e1,000–1,200 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5, GLZT7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5 ton\u003c\/td\u003e\n\u003ctd\u003e1,250–1,500 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 ton\u003c\/td\u003e\n\u003ctd\u003e1,500–1,800 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5, GLZT7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.5 ton\u003c\/td\u003e\n\u003ctd\u003e1,750–2,100 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 ton\u003c\/td\u003e\n\u003ctd\u003e2,000–2,400 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5, GLZT7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 ton\u003c\/td\u003e\n\u003ctd\u003e2,500–3,000 sq ft\u003c\/td\u003e\n\u003ctd\u003eGLZS4, GLZS5, GLZT7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e*Rough guide only. Climate, insulation, and ductwork matter. A Manual J load calculation is the right way to size a system.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat's the difference between single-stage and two-stage?\u003c\/h3\u003e\n\u003cp\u003eA single-stage heat pump runs at full output whenever it's on. A two-stage GLZT7 runs on a lower stage most of the time, so cycles are longer and quieter, temperatures are steadier, and it removes more humidity in summer.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, 5 kW is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I pair these with my existing indoor unit?\u003c\/h3\u003e\n\u003cp\u003eNo. R-32 systems need a matched R-32 air handler. Replace the indoor and outdoor units together.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. The line set must be the correct size and in good condition, and your installer should verify and flush it first.\u003c\/p\u003e\n\u003ch3\u003eHow are these shipped?\u003c\/h3\u003e\n\u003cp\u003eBy freight with liftgate delivery to the 48 contiguous states. Inspect both units for damage before signing.\u003c\/p\u003e\n\u003ch3\u003eDo contractors get better pricing?\u003c\/h3\u003e\n\u003cp\u003eYes. Licensed contractors can apply for trade pricing through our \u003ca href=\"https:\/\/business.acunitsforless.com\/\"\u003eB2B portal\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"goodman-1-5-ton-r32-heat-pump-system-glzs4ba1810","title":"Goodman 1.5 Ton 15.2 SEER2 R-32 Heat Pump System | GLZS4BA1810 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA1810\u003c\/strong\u003e 1.5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA1810 1.5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST24BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST30BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215218017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA1810 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 Ton (18,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 750–900 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA1810. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST24BU1300 (17.5\" cabinet) \/ None","offer_id":55904452018467,"sku":"GLZS4BA1810-AMST24BU1300","price":3898.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904452051235,"sku":"GLZS4BA1810-AMST24BU1300-HKTSN05X1","price":4009.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904452084003,"sku":"GLZS4BA1810-AMST24BU1300-HKTSN08X1","price":4036.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ None","offer_id":55904452116771,"sku":"GLZS4BA1810-AMST30BU1300","price":3962.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904452149539,"sku":"GLZS4BA1810-AMST30BU1300-HKTSN05X1","price":4073.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904452182307,"sku":"GLZS4BA1810-AMST30BU1300-HKTSN08X1","price":4100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-2-ton-r32-heat-pump-system-glzs4ba2410","title":"Goodman 2 Ton 15.2 SEER2 R-32 Heat Pump System | GLZS4BA2410 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA2410\u003c\/strong\u003e 2 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA2410 2 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST24BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST30BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215218022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA2410 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e2 Ton (24,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,000–1,200 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA2410. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST24BU1300 (17.5\" cabinet) \/ None","offer_id":55904452444451,"sku":"GLZS4BA2410-AMST24BU1300","price":3977.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904452477219,"sku":"GLZS4BA2410-AMST24BU1300-HKTSN05X1","price":4088.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904452509987,"sku":"GLZS4BA2410-AMST24BU1300-HKTSN08X1","price":4115.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ None","offer_id":55904452542755,"sku":"GLZS4BA2410-AMST30BU1300","price":4041.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904452575523,"sku":"GLZS4BA2410-AMST30BU1300-HKTSN05X1","price":4152.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904452608291,"sku":"GLZS4BA2410-AMST30BU1300-HKTSN08X1","price":4179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-2-ton-split-heat-pump-152-seer2-hspf-single-stagegoodmanacunitsforless-313471..jpg?v=1778876229"},{"product_id":"goodman-2-5-ton-r32-heat-pump-system-glzs4ba3010","title":"Goodman 2.5 Ton 14.5 SEER2 R-32 Heat Pump System | GLZS4BA3010 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA3010\u003c\/strong\u003e 2.5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA3010 2.5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST30BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e14.5 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213872\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA3010 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 Ton (30,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003e14.5 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,250–1,500 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA3010. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST30BU1300 (17.5\" cabinet) \/ None","offer_id":55904452739363,"sku":"GLZS4BA3010-AMST30BU1300","price":4414.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904452772131,"sku":"GLZS4BA3010-AMST30BU1300-HKTSN05X1","price":4525.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904452804899,"sku":"GLZS4BA3010-AMST30BU1300-HKTSN08X1","price":4552.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55904452837667,"sku":"GLZS4BA3010-AMST30BU1300-HKTSN10X1","price":4563.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-3-ton-r32-heat-pump-system-glzs4ba3610","title":"Goodman 3 Ton Up to 15.2 SEER2 R-32 Heat Pump System | GLZS4BA3610 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA3610\u003c\/strong\u003e 3 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA3610 3 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST36CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.0 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST42CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215217493\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA3610 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 15.2 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,500–1,800 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA3610. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST36CU1300 (21\" cabinet) \/ None","offer_id":55904453132579,"sku":"GLZS4BA3610-AMST36CU1300","price":4971.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904453165347,"sku":"GLZS4BA3610-AMST36CU1300-HKTSN05X1","price":5082.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904453198115,"sku":"GLZS4BA3610-AMST36CU1300-HKTSN08X1","price":5109.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55904453230883,"sku":"GLZS4BA3610-AMST36CU1300-HKTSN10X1","price":5120.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ None","offer_id":55904453263651,"sku":"GLZS4BA3610-AMST42CU1300","price":5033.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904453296419,"sku":"GLZS4BA3610-AMST42CU1300-HKTSN05X1","price":5144.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904453329187,"sku":"GLZS4BA3610-AMST42CU1300-HKTSN08X1","price":5171.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55904453361955,"sku":"GLZS4BA3610-AMST42CU1300-HKTSN10X1","price":5182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-3-5-ton-r32-heat-pump-system-glzs4ba4210","title":"Goodman 3.5 Ton 15.2 SEER2 R-32 Heat Pump System | GLZS4BA4210 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA4210\u003c\/strong\u003e 3.5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA4210 3.5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST42CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213860\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA4210 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e3.5 Ton (42,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,750–2,100 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA4210. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST42CU1300 (21\" cabinet) \/ None","offer_id":55904453427491,"sku":"GLZS4BA4210-AMST42CU1300","price":5291.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904453460259,"sku":"GLZS4BA4210-AMST42CU1300-HKTSN05X1","price":5402.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904453493027,"sku":"GLZS4BA4210-AMST42CU1300-HKTSN08X1","price":5429.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55904453525795,"sku":"GLZS4BA4210-AMST42CU1300-HKTSN10X1","price":5440.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-4-ton-r32-heat-pump-system-glzs4ba4810","title":"Goodman 4 Ton 15.2 SEER2 R-32 Heat Pump System | GLZS4BA4810 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA4810\u003c\/strong\u003e 4 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA4810 4 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST48CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213861\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA4810 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,000–2,400 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA4810. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST48CU1300 (21\" cabinet) \/ None","offer_id":55904453820707,"sku":"GLZS4BA4810-AMST48CU1300","price":5673.0,"currency_code":"USD","in_stock":true},{"title":"AMST48CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904453853475,"sku":"GLZS4BA4810-AMST48CU1300-HKTSN05X1","price":5784.0,"currency_code":"USD","in_stock":true},{"title":"AMST48CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904453886243,"sku":"GLZS4BA4810-AMST48CU1300-HKTSN08X1","price":5811.0,"currency_code":"USD","in_stock":true},{"title":"AMST48CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55904453919011,"sku":"GLZS4BA4810-AMST48CU1300-HKTSN10X1","price":5822.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-5-ton-r32-heat-pump-system-glzs4ba6010","title":"Goodman 5 Ton 14.5 SEER2 R-32 Heat Pump System | GLZS4BA6010 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman split heat pump system: the \u003cstrong\u003eGLZS4BA6010\u003c\/strong\u003e 5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. One system handles cooling in summer and heat pump heating in winter, with an optional HKTSN electric heat kit for backup heat. Choose your air handler and heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS4BA6010 5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST60DU1300\u003c\/td\u003e\n\u003ctd\u003e24.5\"\u003c\/td\u003e\n\u003ctd\u003e14.5 SEER2\u003c\/td\u003e\n\u003ctd\u003e215213862\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eHeat pumps lose capacity as outdoor temperatures drop. A field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). In mild climates, many installers choose the smaller kit; in colder climates, size the kit to the home's heat loss. Confirm kit and breaker sizing against the AMST installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS4BA6010 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem efficiency\u003c\/td\u003e\n\u003ctd\u003e14.5 SEER2 (varies by air handler; see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering\u003c\/td\u003e\n\u003ctd\u003eFactory-installed TXV in air handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,500–3,000 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration (5-year if not registered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhich air handler should I choose?\u003c\/h3\u003e\n\u003cp\u003ePick the cabinet width that fits your closet, attic, or crawlspace. Every option listed is AHRI matched to the GLZS4BA6010. Where two are offered, the larger one gives a slightly higher SEER2 rating.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. In mild climates, a 5 kW kit is common. In colder areas, size the kit to the home's heat loss.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST60DU1300 (24.5\" cabinet) \/ None","offer_id":55904454050083,"sku":"GLZS4BA6010-AMST60DU1300","price":6560.0,"currency_code":"USD","in_stock":true},{"title":"AMST60DU1300 (24.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55904454082851,"sku":"GLZS4BA6010-AMST60DU1300-HKTSN05X1","price":6671.0,"currency_code":"USD","in_stock":true},{"title":"AMST60DU1300 (24.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55904454115619,"sku":"GLZS4BA6010-AMST60DU1300-HKTSN08X1","price":6698.0,"currency_code":"USD","in_stock":true},{"title":"AMST60DU1300 (24.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55904454148387,"sku":"GLZS4BA6010-AMST60DU1300-HKTSN10X1","price":6709.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-1-5-ton-r32-high-efficiency-heat-pump-system-glzs5ba1810","title":"Goodman 1.5 Ton 15.2 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA1810 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA1810\u003c\/strong\u003e 1.5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your air handler and optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA1810 1.5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST24BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST30BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215382240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA1810 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e1.5 Ton (18,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 750–900 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST24BU1300 (17.5\" cabinet) \/ None","offer_id":55906081407267,"sku":"GLZS5BA1810-AMST24BU1300","price":4513.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906081440035,"sku":"GLZS5BA1810-AMST24BU1300-HKTSN05X1","price":4624.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906081472803,"sku":"GLZS5BA1810-AMST24BU1300-HKTSN08X1","price":4651.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ None","offer_id":55906081505571,"sku":"GLZS5BA1810-AMST30BU1300","price":4577.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906081538339,"sku":"GLZS5BA1810-AMST30BU1300-HKTSN05X1","price":4688.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906081571107,"sku":"GLZS5BA1810-AMST30BU1300-HKTSN08X1","price":4715.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-2-ton-r32-high-efficiency-heat-pump-system-glzs5ba2410","title":"Goodman 2 Ton 15.2 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA2410 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA2410\u003c\/strong\u003e 2 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your air handler and optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA2410 2 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST24BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST30BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215382355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA2410 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e2 Ton (24,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,000–1,200 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST24BU1300 (17.5\" cabinet) \/ None","offer_id":55906084159779,"sku":"GLZS5BA2410-AMST24BU1300","price":4612.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906084192547,"sku":"GLZS5BA2410-AMST24BU1300-HKTSN05X1","price":4723.0,"currency_code":"USD","in_stock":true},{"title":"AMST24BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906084225315,"sku":"GLZS5BA2410-AMST24BU1300-HKTSN08X1","price":4750.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ None","offer_id":55906084258083,"sku":"GLZS5BA2410-AMST30BU1300","price":4676.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906084290851,"sku":"GLZS5BA2410-AMST30BU1300-HKTSN05X1","price":4787.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906084323619,"sku":"GLZS5BA2410-AMST30BU1300-HKTSN08X1","price":4814.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_3_Ton_17.2_SEER2_Two-Stage_R-32_Heat_Pump_System_GLZT7CA3610_AMVT_Variable-Speed_Air_Handler_addb6d0d-1759-471c-b234-8fd1e01c40e0.png?v=1793672445"},{"product_id":"goodman-2-5-ton-r32-high-efficiency-heat-pump-system-glzs5ba3010","title":"Goodman 2.5 Ton Up to 15.2 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA3010 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA3010\u003c\/strong\u003e 2.5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your air handler and optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA3010 2.5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (model per your selection), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler options (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST30BU1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAMST36CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e14.5 SEER2\u003c\/td\u003e\n\u003ctd\u003e215382492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA3010 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 Ton (30,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 15.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,250–1,500 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST30BU1300 (17.5\" cabinet) \/ None","offer_id":55906087665955,"sku":"GLZS5BA3010-AMST30BU1300","price":5031.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906087698723,"sku":"GLZS5BA3010-AMST30BU1300-HKTSN05X1","price":5142.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906087731491,"sku":"GLZS5BA3010-AMST30BU1300-HKTSN08X1","price":5169.0,"currency_code":"USD","in_stock":true},{"title":"AMST30BU1300 (17.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906087764259,"sku":"GLZS5BA3010-AMST30BU1300-HKTSN10X1","price":5180.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ None","offer_id":55906087797027,"sku":"GLZS5BA3010-AMST36CU1300","price":5178.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906087829795,"sku":"GLZS5BA3010-AMST36CU1300-HKTSN05X1","price":5289.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906087862563,"sku":"GLZS5BA3010-AMST36CU1300-HKTSN08X1","price":5316.0,"currency_code":"USD","in_stock":true},{"title":"AMST36CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906087895331,"sku":"GLZS5BA3010-AMST36CU1300-HKTSN10X1","price":5327.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_3_Ton_17.2_SEER2_Two-Stage_R-32_Heat_Pump_System_GLZT7CA3610_AMVT_Variable-Speed_Air_Handler_addb6d0d-1759-471c-b234-8fd1e01c40e0.png?v=1793672445"},{"product_id":"goodman-3-ton-r32-high-efficiency-heat-pump-system-glzs5ba3610","title":"Goodman 3 Ton 15.2 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA3610 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA3610\u003c\/strong\u003e 3 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA3610 3 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (AMST42CU1300), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST42CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381162\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA3610 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,500–1,800 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST42CU1300 (21\" cabinet) \/ None","offer_id":55906089533731,"sku":"GLZS5BA3610-AMST42CU1300","price":5575.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906089566499,"sku":"GLZS5BA3610-AMST42CU1300-HKTSN05X1","price":5686.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906089599267,"sku":"GLZS5BA3610-AMST42CU1300-HKTSN08X1","price":5713.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906089632035,"sku":"GLZS5BA3610-AMST42CU1300-HKTSN10X1","price":5724.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-3-5-ton-r32-high-efficiency-heat-pump-system-glzs5ba4210","title":"Goodman 3.5 Ton 15.2 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA4210 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA4210\u003c\/strong\u003e 3.5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA4210 3.5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (AMST42CU1300), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST42CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381163\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA4210 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e3.5 Ton (42,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,750–2,100 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST42CU1300 (21\" cabinet) \/ None","offer_id":55906090713379,"sku":"GLZS5BA4210-AMST42CU1300","price":5876.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906090746147,"sku":"GLZS5BA4210-AMST42CU1300-HKTSN05X1","price":5987.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906090778915,"sku":"GLZS5BA4210-AMST42CU1300-HKTSN08X1","price":6014.0,"currency_code":"USD","in_stock":true},{"title":"AMST42CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906090811683,"sku":"GLZS5BA4210-AMST42CU1300-HKTSN10X1","price":6025.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-4-ton-r32-high-efficiency-heat-pump-system-glzs5ba4810","title":"Goodman 4 Ton 15.2 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA4810 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA4810\u003c\/strong\u003e 4 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA4810 4 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (AMST48CU1300), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST48CU1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381164\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA4810 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e15.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,000–2,400 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST48CU1300 (21\" cabinet) \/ None","offer_id":55906091172131,"sku":"GLZS5BA4810-AMST48CU1300","price":6314.0,"currency_code":"USD","in_stock":true},{"title":"AMST48CU1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906091204899,"sku":"GLZS5BA4810-AMST48CU1300-HKTSN05X1","price":6425.0,"currency_code":"USD","in_stock":true},{"title":"AMST48CU1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906091237667,"sku":"GLZS5BA4810-AMST48CU1300-HKTSN08X1","price":6452.0,"currency_code":"USD","in_stock":true},{"title":"AMST48CU1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906091270435,"sku":"GLZS5BA4810-AMST48CU1300-HKTSN10X1","price":6463.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-5-ton-r32-high-efficiency-heat-pump-system-glzs5ba6010","title":"Goodman 5 Ton 16.0 SEER2 R-32 High-Efficiency Heat Pump System | GLZS5BA6010 + AMST Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZS5\u003c\/strong\u003e high-efficiency heat pump system: the \u003cstrong\u003eGLZS5BA6010\u003c\/strong\u003e 5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMST multi-position air handler\u003c\/strong\u003e. The GLZS5 is Goodman's higher-heating-efficiency single-stage line, rated up to 8.2 HSPF2, so it is a good fit where the heat pump carries most of the winter heating. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZS5BA6010 5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMST multi-position air handler (AMST60DU1300), 9-speed ECM blower, factory-installed TXV\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMST60DU1300\u003c\/td\u003e\n\u003ctd\u003e24.5\"\u003c\/td\u003e\n\u003ctd\u003e16.0 SEER2\u003c\/td\u003e\n\u003ctd\u003e215381165\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZS5BA6010 split heat pump, single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e16.0 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMST multi-position (upflow, horizontal left\/right; downflow with kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e9-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,500–3,000 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003cli\u003eDownflow installation requires a separately purchased Goodman downflow kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eGLZS5 or GLZS4?\u003c\/h3\u003e\u003cp\u003eBoth are single-stage R-32 heat pumps. The GLZS5 has a higher heating efficiency rating (HSPF2), which saves more in climates with real winters. In mild climates, the GLZS4 usually makes more sense.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMST60DU1300 (24.5\" cabinet) \/ None","offer_id":55906092187939,"sku":"GLZS5BA6010-AMST60DU1300","price":7400.0,"currency_code":"USD","in_stock":true},{"title":"AMST60DU1300 (24.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906092220707,"sku":"GLZS5BA6010-AMST60DU1300-HKTSN05X1","price":7511.0,"currency_code":"USD","in_stock":true},{"title":"AMST60DU1300 (24.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906092253475,"sku":"GLZS5BA6010-AMST60DU1300-HKTSN08X1","price":7538.0,"currency_code":"USD","in_stock":true},{"title":"AMST60DU1300 (24.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906092286243,"sku":"GLZS5BA6010-AMST60DU1300-HKTSN10X1","price":7549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_3_Ton_17.2_SEER2_Two-Stage_R-32_Heat_Pump_System_GLZT7CA3610_AMVT_Variable-Speed_Air_Handler_addb6d0d-1759-471c-b234-8fd1e01c40e0.png?v=1793672445"},{"product_id":"goodman-2-ton-two-stage-r32-heat-pump-system-glzt7ca2410","title":"Goodman 2 Ton 17.5 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA2410 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA2410\u003c\/strong\u003e 2 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA2410 2 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT30BP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT30BP1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e17.5 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657363\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA2410 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e2 Ton (24,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e17.5 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,000–1,200 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\u003ch3\u003eWhy is the air handler a larger size than the outdoor unit?\u003c\/h3\u003e\u003cp\u003eThis pairing is the AHRI-certified match for this outdoor unit. The variable-speed blower adjusts airflow to the system, so the cabinet size is not a mismatch.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT30BP1300 (17.5\" cabinet) \/ None","offer_id":55906093039907,"sku":"GLZT7CA2410-AMVT30BP1300","price":6353.0,"currency_code":"USD","in_stock":true},{"title":"AMVT30BP1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906093072675,"sku":"GLZT7CA2410-AMVT30BP1300-HKTSN05X1","price":6464.0,"currency_code":"USD","in_stock":true},{"title":"AMVT30BP1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906093105443,"sku":"GLZT7CA2410-AMVT30BP1300-HKTSN08X1","price":6491.0,"currency_code":"USD","in_stock":true},{"title":"AMVT30BP1300 (17.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906093138211,"sku":"GLZT7CA2410-AMVT30BP1300-HKTSN10X1","price":6502.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-3-ton-two-stage-r32-heat-pump-system-glzt7ca3610","title":"Goodman 3 Ton 17.2 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA3610 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA3610\u003c\/strong\u003e 3 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA3610 3 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT42CP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT42CP1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657364\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA3610 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,500–1,800 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\u003ch3\u003eWhy is the air handler a larger size than the outdoor unit?\u003c\/h3\u003e\u003cp\u003eThis pairing is the AHRI-certified match for this outdoor unit. The variable-speed blower adjusts airflow to the system, so the cabinet size is not a mismatch.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT42CP1300 (21\" cabinet) \/ None","offer_id":55906094055715,"sku":"GLZT7CA3610-AMVT42CP1300","price":7139.0,"currency_code":"USD","in_stock":true},{"title":"AMVT42CP1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906094088483,"sku":"GLZT7CA3610-AMVT42CP1300-HKTSN05X1","price":7250.0,"currency_code":"USD","in_stock":true},{"title":"AMVT42CP1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906094121251,"sku":"GLZT7CA3610-AMVT42CP1300-HKTSN08X1","price":7277.0,"currency_code":"USD","in_stock":true},{"title":"AMVT42CP1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906094154019,"sku":"GLZT7CA3610-AMVT42CP1300-HKTSN10X1","price":7288.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_3_Ton_17.2_SEER2_Two-Stage_R-32_Heat_Pump_System_GLZT7CA3610_AMVT_Variable-Speed_Air_Handler_addb6d0d-1759-471c-b234-8fd1e01c40e0.png?v=1793672445"},{"product_id":"goodman-4-ton-two-stage-r32-heat-pump-system-glzt7ca4810","title":"Goodman 4 Ton 17.2 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA4810 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA4810\u003c\/strong\u003e 4 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA4810 4 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT60DP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT60DP1300\u003c\/td\u003e\n\u003ctd\u003e24.5\"\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657366\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA4810 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,000–2,400 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\u003ch3\u003eWhy is the air handler a larger size than the outdoor unit?\u003c\/h3\u003e\u003cp\u003eThis pairing is the AHRI-certified match for this outdoor unit. The variable-speed blower adjusts airflow to the system, so the cabinet size is not a mismatch.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT60DP1300 (24.5\" cabinet) \/ None","offer_id":55906154610979,"sku":"GLZT7CA4810-AMVT60DP1300","price":8497.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906154643747,"sku":"GLZT7CA4810-AMVT60DP1300-HKTSN05X1","price":8608.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906154676515,"sku":"GLZT7CA4810-AMVT60DP1300-HKTSN08X1","price":8635.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906154709283,"sku":"GLZT7CA4810-AMVT60DP1300-HKTSN10X1","price":8646.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman4Ton17.2SEER2Two-StageR-32HeatPumpSystem_d123468f-dcd2-43ec-b0f4-bbceb9252764.png?v=1793672239"},{"product_id":"goodman-5-ton-two-stage-r32-heat-pump-system-glzt7ca6010","title":"Goodman 5 Ton 16.2 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA6010 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA6010\u003c\/strong\u003e 5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA6010 5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT60DP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT60DP1300\u003c\/td\u003e\n\u003ctd\u003e24.5\"\u003c\/td\u003e\n\u003ctd\u003e16.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657368\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA6010 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e16.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,500–3,000 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT60DP1300 (24.5\" cabinet) \/ None","offer_id":55906155757859,"sku":"GLZT7CA6010-AMVT60DP1300","price":9342.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906155790627,"sku":"GLZT7CA6010-AMVT60DP1300-HKTSN05X1","price":9453.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906155823395,"sku":"GLZT7CA6010-AMVT60DP1300-HKTSN08X1","price":9480.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906155856163,"sku":"GLZT7CA6010-AMVT60DP1300-HKTSN10X1","price":9491.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman5Ton16.2SEER2Two-StageR-32HeatPumpSystem_9c753d7a-3a2b-47f0-b6e7-ecde7de27080.png?v=1793672162"}],"url":"https:\/\/www.acunitsforless.com\/collections\/goodman-r32-heat-pump-systems.oembed","provider":"acunitsforless.com","version":"1.0","type":"link"}