{"title":"Goodman GLZT7 Two-Stage Heat Pump Systems","description":"\u003cp\u003eThe \u003cstrong\u003eGoodman GLZT7\u003c\/strong\u003e is a two-stage R-32 heat pump, paired with Goodman's \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Systems are rated 16.2–17.5 SEER2 and come in 2, 3, 4 and 5 ton.\u003c\/p\u003e\u003cp\u003eTwo-stage operation runs on low stage most of the time: longer, quieter cycles, steadier temperatures and better humidity control than a single-stage system. The AMVT air handler is communicating-capable and also runs on standard two-stage heat pump thermostats.\u003c\/p\u003e\u003cp\u003eCompare every Goodman series in our \u003ca href=\"\/collections\/goodman-r32-heat-pump-systems\"\u003eGoodman R-32 Heat Pump Systems\u003c\/a\u003e collection, or use the \u003ca href=\"\/pages\/sizing-estimator-for-heating-cooling-equipment\"\u003eSizing Estimator\u003c\/a\u003e to find your size.\u003c\/p\u003e","products":[{"product_id":"goodman-2-ton-two-stage-r32-heat-pump-system-glzt7ca2410","title":"Goodman 2 Ton 17.5 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA2410 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA2410\u003c\/strong\u003e 2 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA2410 2 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT30BP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT30BP1300\u003c\/td\u003e\n\u003ctd\u003e17.5\"\u003c\/td\u003e\n\u003ctd\u003e17.5 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657363\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA2410 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e2 Ton (24,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e17.5 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,000–1,200 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\u003ch3\u003eWhy is the air handler a larger size than the outdoor unit?\u003c\/h3\u003e\u003cp\u003eThis pairing is the AHRI-certified match for this outdoor unit. The variable-speed blower adjusts airflow to the system, so the cabinet size is not a mismatch.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT30BP1300 (17.5\" cabinet) \/ None","offer_id":55906093039907,"sku":"GLZT7CA2410-AMVT30BP1300","price":6353.0,"currency_code":"USD","in_stock":true},{"title":"AMVT30BP1300 (17.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906093072675,"sku":"GLZT7CA2410-AMVT30BP1300-HKTSN05X1","price":6464.0,"currency_code":"USD","in_stock":true},{"title":"AMVT30BP1300 (17.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906093105443,"sku":"GLZT7CA2410-AMVT30BP1300-HKTSN08X1","price":6491.0,"currency_code":"USD","in_stock":true},{"title":"AMVT30BP1300 (17.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906093138211,"sku":"GLZT7CA2410-AMVT30BP1300-HKTSN10X1","price":6502.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman2Ton17.5SEER2Two-StageR-32HeatPumpSystemGLZT7CA2410_AMVTVariable-SpeedAirHandler_8caa0fb0-c466-4eb8-92e6-d562e370ff58.png?v=1793672513"},{"product_id":"goodman-3-ton-two-stage-r32-heat-pump-system-glzt7ca3610","title":"Goodman 3 Ton 17.2 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA3610 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA3610\u003c\/strong\u003e 3 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA3610 3 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT42CP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT42CP1300\u003c\/td\u003e\n\u003ctd\u003e21\"\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657364\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA3610 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e3 Ton (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 1,500–1,800 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\u003ch3\u003eWhy is the air handler a larger size than the outdoor unit?\u003c\/h3\u003e\u003cp\u003eThis pairing is the AHRI-certified match for this outdoor unit. The variable-speed blower adjusts airflow to the system, so the cabinet size is not a mismatch.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT42CP1300 (21\" cabinet) \/ None","offer_id":55906094055715,"sku":"GLZT7CA3610-AMVT42CP1300","price":7139.0,"currency_code":"USD","in_stock":true},{"title":"AMVT42CP1300 (21\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906094088483,"sku":"GLZT7CA3610-AMVT42CP1300-HKTSN05X1","price":7250.0,"currency_code":"USD","in_stock":true},{"title":"AMVT42CP1300 (21\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906094121251,"sku":"GLZT7CA3610-AMVT42CP1300-HKTSN08X1","price":7277.0,"currency_code":"USD","in_stock":true},{"title":"AMVT42CP1300 (21\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906094154019,"sku":"GLZT7CA3610-AMVT42CP1300-HKTSN10X1","price":7288.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_3_Ton_17.2_SEER2_Two-Stage_R-32_Heat_Pump_System_GLZT7CA3610_AMVT_Variable-Speed_Air_Handler_addb6d0d-1759-471c-b234-8fd1e01c40e0.png?v=1793672445"},{"product_id":"goodman-4-ton-two-stage-r32-heat-pump-system-glzt7ca4810","title":"Goodman 4 Ton 17.2 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA4810 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA4810\u003c\/strong\u003e 4 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA4810 4 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT60DP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT60DP1300\u003c\/td\u003e\n\u003ctd\u003e24.5\"\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657366\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA4810 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 Ton (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e17.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,000–2,400 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\u003ch3\u003eWhy is the air handler a larger size than the outdoor unit?\u003c\/h3\u003e\u003cp\u003eThis pairing is the AHRI-certified match for this outdoor unit. The variable-speed blower adjusts airflow to the system, so the cabinet size is not a mismatch.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT60DP1300 (24.5\" cabinet) \/ None","offer_id":55906154610979,"sku":"GLZT7CA4810-AMVT60DP1300","price":8497.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906154643747,"sku":"GLZT7CA4810-AMVT60DP1300-HKTSN05X1","price":8608.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906154676515,"sku":"GLZT7CA4810-AMVT60DP1300-HKTSN08X1","price":8635.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906154709283,"sku":"GLZT7CA4810-AMVT60DP1300-HKTSN10X1","price":8646.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman4Ton17.2SEER2Two-StageR-32HeatPumpSystem_d123468f-dcd2-43ec-b0f4-bbceb9252764.png?v=1793672239"},{"product_id":"goodman-5-ton-two-stage-r32-heat-pump-system-glzt7ca6010","title":"Goodman 5 Ton 16.2 SEER2 Two-Stage R-32 Heat Pump System | GLZT7CA6010 + AMVT Variable-Speed Air Handler","description":"\u003cp\u003eAn AHRI-matched Goodman \u003cstrong\u003eGLZT7\u003c\/strong\u003e two-stage heat pump system: the \u003cstrong\u003eGLZT7CA6010\u003c\/strong\u003e 5 ton R-32 outdoor heat pump paired with a Goodman \u003cstrong\u003eAMVT variable-speed air handler\u003c\/strong\u003e. Two-stage operation runs on low stage most of the time, which means longer, quieter cycles, steadier temperatures, and better humidity control than a single-stage system. Choose your optional HKTSN heat kit above; the price updates with your selection.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Goodman GLZT7CA6010 5 Ton R-32 split heat pump (outdoor unit)\u003c\/li\u003e\n\u003cli\u003e1 × Goodman AMVT variable-speed air handler (AMVT60DP1300), variable-speed ECM blower\u003c\/li\u003e\n\u003cli\u003e1 × Goodman HKTSN electric heat kit, if selected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot included: line set, thermostat, condenser pad, disconnect, or installation. These are available in the accessories section below.\u003c\/p\u003e\n\u003ch2\u003eAir handler match (AHRI matched)\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAir handler\u003c\/th\u003e\n\u003cth\u003eCabinet width\u003c\/th\u003e\n\u003cth\u003eSystem rating\u003c\/th\u003e\n\u003cth\u003eAHRI certificate\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eAMVT60DP1300\u003c\/td\u003e\n\u003ctd\u003e24.5\"\u003c\/td\u003e\n\u003ctd\u003e16.2 SEER2\u003c\/td\u003e\n\u003ctd\u003e215657368\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHeat kit options\u003c\/h2\u003e\n\u003cp\u003eA field-installed HKTSN electric heat kit provides supplemental and emergency heat. Available with this system: 5 kW (HKTSN05X1), 8 kW (HKTSN08X1), 10 kW (HKTSN10X1). Size the kit to the home's heat loss, and confirm kit and breaker sizing against the air handler installation manual and local code.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003eGoodman GLZT7CA6010 split heat pump, two-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 Ton (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling efficiency\u003c\/td\u003e\n\u003ctd\u003e16.2 SEER2 (see AHRI table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating efficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 8.2 HSPF2 (outdoor unit rating; system rating varies by match)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir handler type\u003c\/td\u003e\n\u003ctd\u003eAMVT multi-position, variable speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003eVariable-speed ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical coverage\u003c\/td\u003e\n\u003ctd\u003eAbout 2,500–3,000 sq ft (rough guide only; size with a Manual J load calculation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year limited parts with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstallation notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eR-32 is an A2L refrigerant. Install to current codes and the manufacturer's instructions, including any refrigerant detection requirements.\u003c\/li\u003e\n\u003cli\u003eInstallation by a licensed HVAC contractor is required to keep the manufacturer warranty valid.\u003c\/li\u003e\n\u003cli\u003eShips by freight with liftgate delivery. Inspect both units for damage before signing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat thermostat do I need?\u003c\/h3\u003e\u003cp\u003eUse a thermostat that supports two-stage heat pump operation with auxiliary heat. Check the installation manual for compatible communicating thermostats if you want to use communicating mode.\u003c\/p\u003e\n\u003ch3\u003eDo I need a heat kit?\u003c\/h3\u003e\n\u003cp\u003eMost heat pump installs include one for backup and defrost heat. Size it to the home's heat loss: smaller kits suit mild climates, larger kits colder ones.\u003c\/p\u003e\n\u003ch3\u003eCan I reuse my existing line set?\u003c\/h3\u003e\n\u003cp\u003eSometimes. Size and condition must suit R-32 and this system's specs. Your installer should verify the line set and flush it if it's being reused.\u003c\/p\u003e\n\u003ch3\u003eIs this compatible with my old R-410A or R-22 equipment?\u003c\/h3\u003e\n\u003cp\u003eNo. Replace both the outdoor unit and the indoor unit together with this matched R-32 system.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"AMVT60DP1300 (24.5\" cabinet) \/ None","offer_id":55906155757859,"sku":"GLZT7CA6010-AMVT60DP1300","price":9342.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 5 kW (HKTSN05X1)","offer_id":55906155790627,"sku":"GLZT7CA6010-AMVT60DP1300-HKTSN05X1","price":9453.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 8 kW (HKTSN08X1)","offer_id":55906155823395,"sku":"GLZT7CA6010-AMVT60DP1300-HKTSN08X1","price":9480.0,"currency_code":"USD","in_stock":true},{"title":"AMVT60DP1300 (24.5\" cabinet) \/ 10 kW (HKTSN10X1)","offer_id":55906155856163,"sku":"GLZT7CA6010-AMVT60DP1300-HKTSN10X1","price":9491.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman5Ton16.2SEER2Two-StageR-32HeatPumpSystem_9c753d7a-3a2b-47f0-b6e7-ecde7de27080.png?v=1793672162"}],"url":"https:\/\/www.acunitsforless.com\/collections\/goodman-glzt7-two-stage-heat-pump-systems.oembed","provider":"acunitsforless.com","version":"1.0","type":"link"}