{"title":"Dual Fuel Systems","description":"\u003cp\u003eDual fuel systems pair an electric heat pump with a high-efficiency gas furnace. The heat pump handles cooling and mild-weather heating, and the furnace takes over automatically when temperatures drop, so you get efficient comfort all year and lower energy bills. Shop Goodman R-32 dual fuel systems, including inverter and two-stage models, in 1.5 to 5 ton sizes with matched coils.\u003c\/p\u003e","products":[{"product_id":"goodman-2-ton-14-3-seer2-r-32-dual-fuel-system-60-000-btu-80-afue-furnace-glzs4ba2410-gr9s800603an-capta2422a3","title":"Goodman 2 Ton 14.3 SEER2 R-32 Dual Fuel System | 60,000 BTU 80% AFUE Furnace | GLZS4BA2410 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GLZS4 heat pump with a 60,000 BTU, 80% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA2410: 2 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800603AN: 60,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 14\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA2422A3: R-32 cased upflow\/downflow coil with TXV, 14\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA2410: 2 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S800603AN: 60,000 BTU, 80% AFUE, single-stage, ECM blower, downflow\/horizontal, 14\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA2422A3: R-32 cased upflow\/downflow coil with TXV, 14\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA2410: 2 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800603BN: 60,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA2426B3: R-32 cased horizontal coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066978218275,"sku":"GLZS4BA2410-GR9S800603AN-CAPTA2422A3","price":4453.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067101557027,"sku":"GLZS4BA2410-GD9S800603AN-CAPTA2422A3","price":4493.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067070165283,"sku":"GLZS4BA2410-GR9S800603BN-CHPTA2426B3","price":4542.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-2-ton-14-3-seer2-r-32-dual-fuel-system-60-000-btu-96-afue-furnace-glzs4ba2410-gr9s960603bn-capta2422b3","title":"Goodman 2 Ton 14.3 SEER2 R-32 Dual Fuel System | 60,000 BTU 96% AFUE Furnace | GLZS4BA2410 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GLZS4 heat pump with a 60,000 BTU, 96% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA2410: 2 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S960603BN: 60,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA2422B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA2410: 2 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S960603BN: 60,000 BTU, 96% AFUE, single-stage, ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA2422B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA2410: 2 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S960603BN: 60,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA2426B3: R-32 cased horizontal coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066978939171,"sku":"GLZS4BA2410-GR9S960603BN-CAPTA2422B3","price":5145.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067103883555,"sku":"GLZS4BA2410-GD9S960603BN-CAPTA2422B3","price":5201.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067070918947,"sku":"GLZS4BA2410-GR9S960603BN-CHPTA2426B3","price":5208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-2-5-ton-14-3-seer2-r-32-dual-fuel-system-60-000-btu-80-afue-furnace-glzs4ba3010-gr9s800603bn-capta3022b3","title":"Goodman 2.5 Ton 14.3 SEER2 R-32 Dual Fuel System | 60,000 BTU 80% AFUE Furnace | GLZS4BA3010 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GLZS4 heat pump with a 60,000 BTU, 80% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3010: 2.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800603BN: 60,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3022B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3010: 2.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S800603AN: 60,000 BTU, 80% AFUE, single-stage, ECM blower, downflow\/horizontal, 14\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3022A3: R-32 cased upflow\/downflow coil with TXV, 14\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3010: 2.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800603BN: 60,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA3026B3: R-32 cased horizontal coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066979332387,"sku":"GLZS4BA3010-GR9S800603BN-CAPTA3022B3","price":4977.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067104047395,"sku":"GLZS4BA3010-GD9S800603AN-CAPTA3022A3","price":4993.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067071705379,"sku":"GLZS4BA3010-GR9S800603BN-CHPTA3026B3","price":4943.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-2-5-ton-14-3-seer2-r-32-dual-fuel-system-60-000-btu-96-afue-furnace-glzs4ba3010-gr9s960603bn-capta3022b3","title":"Goodman 2.5 Ton 14.3 SEER2 R-32 Dual Fuel System | 60,000 BTU 96% AFUE Furnace | GLZS4BA3010 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GLZS4 heat pump with a 60,000 BTU, 96% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3010: 2.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S960603BN: 60,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3022B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3010: 2.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S960603BN: 60,000 BTU, 96% AFUE, single-stage, ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3022B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3010: 2.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S960603BN: 60,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA3026B3: R-32 cased horizontal coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066980118819,"sku":"GLZS4BA3010-GR9S960603BN-CAPTA3022B3","price":5643.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067104407843,"sku":"GLZS4BA3010-GD9S960603BN-CAPTA3022B3","price":5699.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067072229667,"sku":"GLZS4BA3010-GR9S960603BN-CHPTA3026B3","price":5609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-3-ton-14-3-seer2-r-32-dual-fuel-system-80-000-btu-80-afue-furnace-glzs4ba3610-gr9s800803bn-capta3626b3","title":"Goodman 3 Ton 14.3 SEER2 R-32 Dual Fuel System | 80,000 BTU 80% AFUE Furnace | GLZS4BA3610 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GLZS4 heat pump with an 80,000 BTU, 80% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3610: 3 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800803BN: 80,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3626B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3610: 3 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S800804BN: 80,000 BTU, 80% AFUE, single-stage, ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3626B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3610: 3 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800803BN: 80,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA3630B3: R-32 cased horizontal coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066981069091,"sku":"GLZS4BA3610-GR9S800803BN-CAPTA3626B3","price":5453.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067104833827,"sku":"GLZS4BA3610-GD9S800804BN-CAPTA3626B3","price":5635.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067076096291,"sku":"GLZS4BA3610-GR9S800803BN-CHPTA3630B3","price":5442.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-3-ton-14-3-seer2-r-32-dual-fuel-system-80-000-btu-96-afue-furnace-glzs4ba3610-gr9s960803bn-capta3626b3","title":"Goodman 3 Ton 14.3 SEER2 R-32 Dual Fuel System | 80,000 BTU 96% AFUE Furnace | GLZS4BA3610 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GLZS4 heat pump with an 80,000 BTU, 96% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3610: 3 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S960803BN: 80,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3626B3: R-32 cased upflow\/downflow coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3610: 3 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S960804CN: 80,000 BTU, 96% AFUE, single-stage, ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA3626C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA3610: 3 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S960803BN: 80,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA3630B3: R-32 cased horizontal coil with TXV, 17.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066981134627,"sku":"GLZS4BA3610-GR9S960803BN-CAPTA3626B3","price":6185.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067105194275,"sku":"GLZS4BA3610-GD9S960804CN-CAPTA3626C3","price":6441.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067076456739,"sku":"GLZS4BA3610-GR9S960803BN-CHPTA3630B3","price":6174.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-3-5-ton-14-3-seer2-r-32-dual-fuel-system-80-000-btu-80-afue-furnace-glzs4ba4210-gr9s800804cn-capta4230c3","title":"Goodman 3.5 Ton 14.3 SEER2 R-32 Dual Fuel System | 80,000 BTU 80% AFUE Furnace | GLZS4BA4210 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GLZS4 heat pump with an 80,000 BTU, 80% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\n\u003ch3\u003eIncluded Components\u003c\/h3\u003e\n\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4210: 3.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800804CN: 80,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA4230C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4210: 3.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S800804CN: 80,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA4230C3: R-32 cased horizontal coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066981396771,"sku":"GLZS4BA4210-GR9S800804CN-CAPTA4230C3","price":5875.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067077046563,"sku":"GLZS4BA4210-GR9S800804CN-CHPTA4230C3","price":5913.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56069699174691,"sku":"GLZS4BA4210-GD9S800805CX-CAPTA4230C3","price":6017.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-3-5-ton-14-3-seer2-r-32-dual-fuel-system-100-000-btu-96-afue-furnace-glzs4ba4210-gr9s961005cn-capta4230c3","title":"Goodman 3.5 Ton 14.3 SEER2 R-32 Dual Fuel System | 100,000 BTU 96% AFUE Furnace | GLZS4BA4210 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GLZS4 heat pump with a 100,000 BTU, 96% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4210: 3.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S961005CN: 100,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA4230C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4210: 3.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S961005CN: 100,000 BTU, 96% AFUE, single-stage, ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA4230C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4210: 3.5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S961005CN: 100,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA4230C3: R-32 cased horizontal coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066981855523,"sku":"GLZS4BA4210-GR9S961005CN-CAPTA4230C3","price":6917.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067106111779,"sku":"GLZS4BA4210-GD9S961005CN-CAPTA4230C3","price":7007.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067077341475,"sku":"GLZS4BA4210-GR9S961005CN-CHPTA4230C3","price":6955.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-4-ton-14-3-seer2-r-32-dual-fuel-system-100-000-btu-80-afue-furnace-glzs4ba4810-gr9s801005cn-capta6030c3","title":"Goodman 4 Ton 14.3 SEER2 R-32 Dual Fuel System | 100,000 BTU 80% AFUE Furnace | GLZS4BA4810 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 4 ton GLZS4 heat pump with a 100,000 BTU, 80% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4810: 4 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S801005CN: 100,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4810: 4 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S801005CN: 100,000 BTU, 80% AFUE, single-stage, ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4810: 4 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S801005CN: 100,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA4830C3: R-32 cased horizontal coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066982576419,"sku":"GLZS4BA4810-GR9S801005CN-CAPTA6030C3","price":6461.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067107029283,"sku":"GLZS4BA4810-GD9S801005CN-CAPTA6030C3","price":6595.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067077800227,"sku":"GLZS4BA4810-GR9S801005CN-CHPTA4830C3","price":6400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-4-ton-14-3-seer2-r-32-dual-fuel-system-100-000-btu-96-afue-furnace-glzs4ba4810-gr9s961005cn-capta6030c3","title":"Goodman 4 Ton 14.3 SEER2 R-32 Dual Fuel System | 100,000 BTU 96% AFUE Furnace | GLZS4BA4810 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 4 ton GLZS4 heat pump with a 100,000 BTU, 96% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4810: 4 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S961005CN: 100,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4810: 4 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S961005CN: 100,000 BTU, 96% AFUE, single-stage, ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA4810: 4 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S961005CN: 100,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA4830C3: R-32 cased horizontal coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066983231779,"sku":"GLZS4BA4810-GR9S961005CN-CAPTA6030C3","price":7377.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067107914019,"sku":"GLZS4BA4810-GD9S961005CN-CAPTA6030C3","price":7467.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067077964067,"sku":"GLZS4BA4810-GR9S961005CN-CHPTA4830C3","price":7316.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-5-ton-14-3-seer2-r-32-dual-fuel-system-120-000-btu-80-afue-furnace-glzs4ba6010-gr9s801205dn-capta6030d3","title":"Goodman 5 Ton 14.3 SEER2 R-32 Dual Fuel System | 100,000–120,000 BTU 80% AFUE Furnace | GLZS4BA6010 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 5 ton GLZS4 heat pump with a 100,000–120,000 BTU, 80% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA6010: 5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S801205DN: 120,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030D3: R-32 cased upflow\/downflow coil with TXV, 24.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA6010: 5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S801005CN: 100,000 BTU, 80% AFUE, single-stage, ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030C3: R-32 cased upflow\/downflow coil with TXV, 21\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA6010: 5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S801205DN: 120,000 BTU, 80% AFUE, single-stage, ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA6030D3: R-32 cased horizontal coil with TXV, 24.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eNote: the downflow configuration uses a 100,000 BTU furnace, because no 120,000 BTU downflow model is available in this series.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066983461155,"sku":"GLZS4BA6010-GR9S801205DN-CAPTA6030D3","price":7345.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067108208931,"sku":"GLZS4BA6010-GD9S801005CN-CAPTA6030C3","price":7236.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067078160675,"sku":"GLZS4BA6010-GR9S801205DN-CHPTA6030D3","price":7303.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-5-ton-14-3-seer2-r-32-dual-fuel-system-120-000-btu-96-afue-furnace-glzs4ba6010-gr9s961205dn-capta6030d3","title":"Goodman 5 Ton 14.3 SEER2 R-32 Dual Fuel System | 120,000 BTU 96% AFUE Furnace | GLZS4BA6010 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 5 ton GLZS4 heat pump with a 120,000 BTU, 96% AFUE Goodman gas furnace and a matching R-32 cased evaporator coil. Choose the configuration for an upflow, downflow or horizontal installation. The heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA6010: 5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S961205DN: 120,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030D3: R-32 cased upflow\/downflow coil with TXV, 24.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA6010: 5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GD9S961205DN: 120,000 BTU, 96% AFUE, single-stage, ECM blower, downflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPTA6030D3: R-32 cased upflow\/downflow coil with TXV, 24.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GLZS4BA6010: 5 ton, 14.3 SEER2, R-32, single-stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GR9S961205DN: 120,000 BTU, 96% AFUE, single-stage, ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPTA6030D3: R-32 cased horizontal coil with TXV, 24.5\" wide\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56066983788835,"sku":"GLZS4BA6010-GR9S961205DN-CAPTA6030D3","price":8227.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56067108733219,"sku":"GLZS4BA6010-GD9S961205DN-CAPTA6030D3","price":8356.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56067078488355,"sku":"GLZS4BA6010-GR9S961205DN-CHPTA6030D3","price":8185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/goodman-15-ton-152-seer-heat-pump-two-piece-vs-blower-mbvc1201aa-1-capta3022b4-gszh501810goodmanacunitsforless-814761..jpg?v=1778867126"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-80-afue-single-stage-ultra-low-nox-furnace-gzv6sa1810-grvs800604bu-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 80% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA1810 | Upflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 80% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS800604BU: 60,000 BTU, 80% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439751\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS800604BU: 60,000 BTU, 80% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439749\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118441902371,"sku":"GZV6SA1810-GRVS800604BU-CAPEA2418C3","price":6047.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118441935139,"sku":"GZV6SA1810-GRVS800604BU-CHPEA2422B3","price":5985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-single-stage-ultra-low-nox-furnace-gzv6sa1810-grvs800805cu-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA1810 | Upflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS800805CU: 80,000 BTU, 80% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439748\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118441967907,"sku":"GZV6SA1810-GRVS800805CU-CAPEA2418C3","price":6321.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-96-afue-single-stage-ultra-low-nox-furnace-gzv6sa1810-grvs960603bu-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 96% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA1810 | Upflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 96% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS960603BU: 60,000 BTU, 96% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439746\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS960603BU: 60,000 BTU, 96% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439744\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442033443,"sku":"GZV6SA1810-GRVS960603BU-CAPEA2418C3","price":6872.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442066211,"sku":"GZV6SA1810-GRVS960603BU-CHPEA2422B3","price":6810.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-single-stage-ultra-low-nox-furnace-gzv6sa1810-grvs960805cu-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA1810 | Upflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS960805CU: 80,000 BTU, 96% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439743\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442098979,"sku":"GZV6SA1810-GRVS960805CU-CAPEA2418C3","price":7464.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-80-afue-two-stage-furnace-gzv6sa1810-grvt800604bn-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA1810 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800604BN: 60,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439738\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800603BX: 60,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439741\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800604BN: 60,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439736\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442131747,"sku":"GZV6SA1810-GRVT800604BN-CAPEA2418C3","price":5816.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118442164515,"sku":"GZV6SA1810-GDVT800603BX-CAPEA2418C3","price":5744.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442197283,"sku":"GZV6SA1810-GRVT800604BN-CHPEA2422B3","price":5754.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-two-stage-furnace-gzv6sa1810-grvt800804cn-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA1810 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800804CN: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439732\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800805CX: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439730\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800803BX: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439733\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442262819,"sku":"GZV6SA1810-GRVT800804CN-CAPEA2418C3","price":5925.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118442295587,"sku":"GZV6SA1810-GDVT800805CX-CAPEA2418C3","price":6058.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442328355,"sku":"GZV6SA1810-GDVT800803BX-CHPEA2422B3","price":5868.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-40000-btu-96-afue-two-stage-furnace-gzv6sa1810-gdvt960403bn-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 40,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA1810 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with a 40,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439728\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439726\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118442361123,"sku":"GZV6SA1810-GDVT960403BN-CAPEA2418C3","price":6287.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442393891,"sku":"GZV6SA1810-GDVT960403BN-CHPEA2422B3","price":6225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-96-afue-two-stage-furnace-gzv6sa1810-gdvt960603bn-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA1810 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439725\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439723\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118442426659,"sku":"GZV6SA1810-GDVT960603BN-CAPEA2418C3","price":6393.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442459427,"sku":"GZV6SA1810-GDVT960603BN-CHPEA2422B3","price":6331.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-1-5-ton-19-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-two-stage-furnace-gzv6sa1810-grvt960803bn-capea2418c3","title":"Goodman 1.5 Ton 19.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA1810 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 1.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439722\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960804CN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439719\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA1810: 1.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 19.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215439720\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442524963,"sku":"GZV6SA1810-GRVT960803BN-CAPEA2418C3","price":6624.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118442557731,"sku":"GZV6SA1810-GDVT960804CN-CAPEA2418C3","price":6854.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442590499,"sku":"GZV6SA1810-GRVT960803BN-CHPEA2422B3","price":6562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-ton-18-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-80-afue-two-stage-furnace-gzv6sa2410-grvt800604bn-chpea2422b3","title":"Goodman 2 Ton 18.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA2410 | Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800604BN: 60,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487279\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Horizontal","offer_id":56118442623267,"sku":"GZV6SA2410-GRVT800604BN-CHPEA2422B3","price":5865.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-ton-18-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-two-stage-furnace-gzv6sa2410-grvt800804cn-capea2418c3","title":"Goodman 2 Ton 18.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA2410 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800804CN: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487275\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800805CX: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487273\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800803BX: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487276\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442688803,"sku":"GZV6SA2410-GRVT800804CN-CAPEA2418C3","price":6036.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118442721571,"sku":"GZV6SA2410-GDVT800805CX-CAPEA2418C3","price":6169.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442754339,"sku":"GZV6SA2410-GDVT800803BX-CHPEA2422B3","price":5979.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-ton-18-0-seer2-r-32-inverter-dual-fuel-system-40000-btu-96-afue-two-stage-furnace-gzv6sa2410-gdvt960403bn-capea2418c3","title":"Goodman 2 Ton 18.0 SEER2 R-32 Inverter Dual Fuel System | 40,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA2410 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GZV6SA variable-speed inverter heat pump with a 40,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487271\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487269\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118442787107,"sku":"GZV6SA2410-GDVT960403BN-CAPEA2418C3","price":6398.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442819875,"sku":"GZV6SA2410-GDVT960403BN-CHPEA2422B3","price":6336.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-ton-18-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-96-afue-two-stage-furnace-gzv6sa2410-gdvt960603bn-capea2418c3","title":"Goodman 2 Ton 18.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA2410 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487268\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487266\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118442885411,"sku":"GZV6SA2410-GDVT960603BN-CAPEA2418C3","price":6504.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118442918179,"sku":"GZV6SA2410-GDVT960603BN-CHPEA2422B3","price":6442.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-ton-18-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-two-stage-furnace-gzv6sa2410-grvt960803bn-capea2418c3","title":"Goodman 2 Ton 18.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA2410 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487265\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960804CN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA2418C3: 2 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487262\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA2410: 2 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 18.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA2422B3: 2 ton R-32 cased horizontal coil with EEV, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487263\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118442950947,"sku":"GZV6SA2410-GRVT960803BN-CAPEA2418C3","price":6735.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118442983715,"sku":"GZV6SA2410-GDVT960804CN-CAPEA2418C3","price":6965.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118443016483,"sku":"GZV6SA2410-GRVT960803BN-CHPEA2422B3","price":6673.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-60000-btu-80-afue-single-stage-ultra-low-nox-furnace-gzv6sa3010-grvs800604bu-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 80% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA3010 | Upflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 80% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS800604BU: 60,000 BTU, 80% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447121\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443082019,"sku":"GZV6SA3010-GRVS800604BU-CAPEA3022C3","price":6513.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-single-stage-ultra-low-nox-furnace-gzv6sa3010-grvs800805cu-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA3010 | Upflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS800805CU: 80,000 BTU, 80% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447122\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443147555,"sku":"GZV6SA3010-GRVS800805CU-CAPEA3022C3","price":6787.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-60000-btu-96-afue-single-stage-ultra-low-nox-furnace-gzv6sa3010-grvs960603bu-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 96% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA3010 | Upflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 96% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS960603BU: 60,000 BTU, 96% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447123\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443180323,"sku":"GZV6SA3010-GRVS960603BU-CAPEA3022C3","price":7338.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-single-stage-ultra-low-nox-furnace-gzv6sa3010-grvs960805cu-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Single-Stage Ultra-Low NOx Furnace | GZV6SA3010 | Upflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE single-stage Goodman gas furnace (ultra-low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVS960805CU: 80,000 BTU, 96% AFUE, single-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide, ultra-low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447124\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443213091,"sku":"GZV6SA3010-GRVS960805CU-CAPEA3022C3","price":7930.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-60000-btu-80-afue-two-stage-furnace-gzv6sa3010-grvt800604bn-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA3010 | Upflow or Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800604BN: 60,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447126\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800603BX: 60,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447125\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443245859,"sku":"GZV6SA3010-GRVT800604BN-CAPEA3022C3","price":6282.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118443278627,"sku":"GZV6SA3010-GDVT800603BX-CAPEA3022C3","price":6210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-two-stage-furnace-gzv6sa3010-grvt800804cn-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA3010 | Upflow or Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800804CN: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447128\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800805CX: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447129\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443311395,"sku":"GZV6SA3010-GRVT800804CN-CAPEA3022C3","price":6391.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118443344163,"sku":"GZV6SA3010-GDVT800805CX-CAPEA3022C3","price":6524.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-100000-btu-80-afue-two-stage-low-nox-furnace-gzv6sa3010-gdvt801005cx-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 80% AFUE Two-Stage Low NOx Furnace | GZV6SA3010 | Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 80% AFUE two-stage Goodman gas furnace (low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT801005CX: 100,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447130\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443442467,"sku":"GZV6SA3010-GDVT801005CX-CAPEA3022C3","price":6672.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-40000-btu-96-afue-two-stage-furnace-gzv6sa3010-gdvt960403bn-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 40,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3010 | Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 40,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447131\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443508003,"sku":"GZV6SA3010-GDVT960403BN-CAPEA3022C3","price":6753.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-60000-btu-96-afue-two-stage-furnace-gzv6sa3010-gdvt960603bn-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3010 | Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447132\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443540771,"sku":"GZV6SA3010-GDVT960603BN-CAPEA3022C3","price":6859.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-two-stage-furnace-gzv6sa3010-grvt960803bn-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3010 | Upflow or Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447133\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960804CN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447134\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443573539,"sku":"GZV6SA3010-GRVT960803BN-CAPEA3022C3","price":7090.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118443606307,"sku":"GZV6SA3010-GDVT960804CN-CAPEA3022C3","price":7320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-2-5-ton-17-5-seer2-r-32-inverter-dual-fuel-system-100000-btu-96-afue-two-stage-furnace-gzv6sa3010-gdvt961005cn-capea3022c3","title":"Goodman 2.5 Ton 17.5 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3010 | Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 2.5 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3010: 2.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961005CN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3022C3: 2.5 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447135\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443671843,"sku":"GZV6SA3010-GDVT961005CN-CAPEA3022C3","price":7484.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-6-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-two-stage-furnace-gzv6sa3610-grvt800805dn-capea3626d3","title":"Goodman 3 Ton 16.6 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA3610 | Upflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.6 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800805DN: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626D3: 3 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447198\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.6 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT800805CX: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA3626C3: 3 ton R-32 cased horizontal coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447199\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118443737379,"sku":"GZV6SA3610-GRVT800805DN-CAPEA3626D3","price":6826.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118443770147,"sku":"GZV6SA3610-GDVT800805CX-CHPEA3626C3","price":6762.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-6-seer2-r-32-inverter-dual-fuel-system-100000-btu-80-afue-two-stage-low-nox-furnace-gzv6sa3610-gdvt801005cx-capea3626d3","title":"Goodman 3 Ton 16.6 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 80% AFUE Two-Stage Low NOx Furnace | GZV6SA3610 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 80% AFUE two-stage Goodman gas furnace (low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.6 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT801005CX: 100,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626D3: 3 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447197\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.6 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT801005CX: 100,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA3626C3: 3 ton R-32 cased horizontal coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447196\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443802915,"sku":"GZV6SA3610-GDVT801005CX-CAPEA3626D3","price":7024.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118443835683,"sku":"GZV6SA3610-GDVT801005CX-CHPEA3626C3","price":6910.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-0-seer2-r-32-inverter-dual-fuel-system-40000-btu-96-afue-two-stage-furnace-gzv6sa3610-gdvt960403bn-capea3626c3","title":"Goodman 3 Ton 16.0 SEER2 R-32 Inverter Dual Fuel System | 40,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3610 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with a 40,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626C3: 3 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447194\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960403BN: 40,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA3626C3: 3 ton R-32 cased horizontal coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447195\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443868451,"sku":"GZV6SA3610-GDVT960403BN-CAPEA3626C3","price":7095.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118443901219,"sku":"GZV6SA3610-GDVT960403BN-CHPEA3626C3","price":6991.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-0-seer2-r-32-inverter-dual-fuel-system-60000-btu-96-afue-two-stage-furnace-gzv6sa3610-gdvt960603bn-capea3626c3","title":"Goodman 3 Ton 16.0 SEER2 R-32 Inverter Dual Fuel System | 60,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3610 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with a 60,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626C3: 3 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447192\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960603BN: 60,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA3626C3: 3 ton R-32 cased horizontal coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447193\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118443999523,"sku":"GZV6SA3610-GDVT960603BN-CAPEA3626C3","price":7201.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118444032291,"sku":"GZV6SA3610-GDVT960603BN-CHPEA3626C3","price":7097.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-two-stage-furnace-gzv6sa3610-grvt960803bn-capea3626c3","title":"Goodman 3 Ton 16.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3610 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626C3: 3 ton R-32 cased upflow\/downflow coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447190\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960804CN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626D3: 3 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447189\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT960803BN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 17.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA3626C3: 3 ton R-32 cased horizontal coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447191\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118444065059,"sku":"GZV6SA3610-GRVT960803BN-CAPEA3626C3","price":7432.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118444097827,"sku":"GZV6SA3610-GDVT960804CN-CAPEA3626D3","price":7672.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118444130595,"sku":"GZV6SA3610-GRVT960803BN-CHPEA3626C3","price":7328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-6-seer2-r-32-inverter-dual-fuel-system-100000-btu-96-afue-two-stage-furnace-gzv6sa3610-grvt961005dn-capea3626d3","title":"Goodman 3 Ton Up to 16.6 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3610 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.6 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT961005DN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626D3: 3 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447185\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961005CN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626D3: 3 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447187\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961005CN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA3626C3: 3 ton R-32 cased horizontal coil with EEV, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447186\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118444163363,"sku":"GZV6SA3610-GRVT961005DN-CAPEA3626D3","price":7859.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118444196131,"sku":"GZV6SA3610-GDVT961005CN-CAPEA3626D3","price":7836.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118444228899,"sku":"GZV6SA3610-GDVT961005CN-CHPEA3626C3","price":7722.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-ton-16-6-seer2-r-32-inverter-dual-fuel-system-120000-btu-96-afue-two-stage-furnace-gzv6sa3610-gdvt961205dn-capea3626d3","title":"Goodman 3 Ton 16.6 SEER2 R-32 Inverter Dual Fuel System | 120,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA3610 | Downflow","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3 ton GZV6SA variable-speed inverter heat pump with a 120,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA3610: 3 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.6 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961205DN: 120,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA3626D3: 3 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447184\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118444261667,"sku":"GZV6SA3610-GDVT961205DN-CAPEA3626D3","price":7981.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System_1_3c420d31-abe9-4018-8bce-50159d835093.webp?v=1795326681"},{"product_id":"goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-80-afue-two-stage-furnace-gzv6sa4210-grvt800805dn-capea6030d3","title":"Goodman 3.5 Ton 17.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 80% AFUE Two-Stage Furnace | GZV6SA4210 | Upflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 80% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800805DN: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA6030D3: 5 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447244\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT800805DN: 80,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447243\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118444294435,"sku":"GZV6SA4210-GRVT800805DN-CAPEA6030D3","price":7244.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118444327203,"sku":"GZV6SA4210-GRVT800805DN-CHPEA4830D3","price":7119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256"},{"product_id":"goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-100000-btu-80-afue-two-stage-low-nox-furnace-gzv6sa4210-gdvt801005cx-capea4830d3","title":"Goodman 3.5 Ton 17.0 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 80% AFUE Two-Stage Low NOx Furnace | GZV6SA4210 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 80% AFUE two-stage Goodman gas furnace (low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT801005CX: 100,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447242\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT801005CX: 100,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447240\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118444392739,"sku":"GZV6SA4210-GDVT801005CX-CAPEA4830D3","price":7411.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118444425507,"sku":"GZV6SA4210-GDVT801005CX-CHPEA4830D3","price":7317.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256"},{"product_id":"goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-80000-btu-96-afue-two-stage-furnace-gzv6sa4210-gdvt960804cn-capea4830d3","title":"Goodman 3.5 Ton Up to 17.0 SEER2 R-32 Inverter Dual Fuel System | 80,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA4210 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GZV6SA variable-speed inverter heat pump with an 80,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960804CN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447239\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT960804CN: 80,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447238\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118444491043,"sku":"GZV6SA4210-GDVT960804CN-CAPEA4830D3","price":8059.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118444523811,"sku":"GZV6SA4210-GDVT960804CN-CHPEA4830D3","price":7965.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256"},{"product_id":"goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-100000-btu-96-afue-two-stage-furnace-gzv6sa4210-grvt961005dn-capea4830d3","title":"Goodman 3.5 Ton Up to 17.0 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA4210 | Upflow, Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an upflow, downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eUpflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT961005DN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447235\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961005CN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447237\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GRVT961005DN: 100,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, upflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447234\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Upflow","offer_id":56118445277475,"sku":"GZV6SA4210-GRVT961005DN-CAPEA4830D3","price":8246.0,"currency_code":"USD","in_stock":true},{"title":"Downflow","offer_id":56118445310243,"sku":"GZV6SA4210-GDVT961005CN-CAPEA4830D3","price":8223.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118445343011,"sku":"GZV6SA4210-GRVT961005DN-CHPEA4830D3","price":8152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256"},{"product_id":"goodman-3-5-ton-17-0-seer2-r-32-inverter-dual-fuel-system-120000-btu-96-afue-two-stage-furnace-gzv6sa4210-gdvt961205dn-capea4830d3","title":"Goodman 3.5 Ton Up to 17.0 SEER2 R-32 Inverter Dual Fuel System | 120,000 BTU 96% AFUE Two-Stage Furnace | GZV6SA4210 | Downflow or Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 3.5 ton GZV6SA variable-speed inverter heat pump with a 120,000 BTU, 96% AFUE two-stage Goodman gas furnace and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an downflow or horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eDownflow Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 17.0 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961205DN: 120,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CAPEA4830D3: 4 ton R-32 cased upflow\/downflow coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447233\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4210: 3.5 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.5 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT961205DN: 120,000 BTU, 96% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215447232\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Downflow","offer_id":56118445375779,"sku":"GZV6SA4210-GDVT961205DN-CAPEA4830D3","price":8368.0,"currency_code":"USD","in_stock":true},{"title":"Horizontal","offer_id":56118445408547,"sku":"GZV6SA4210-GDVT961205DN-CHPEA4830D3","price":8274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256"},{"product_id":"goodman-4-ton-16-7-seer2-r-32-inverter-dual-fuel-system-100000-btu-80-afue-two-stage-low-nox-furnace-gzv6sa4810-gdvt801005cx-chpea4830d3","title":"Goodman 4 Ton 16.7 SEER2 R-32 Inverter Dual Fuel System | 100,000 BTU 80% AFUE Two-Stage Low NOx Furnace | GZV6SA4810 | Horizontal","description":"\u003cp\u003eThis is a complete Goodman R-32 dual fuel split system. It pairs a 4 ton GZV6SA variable-speed inverter heat pump with a 100,000 BTU, 80% AFUE two-stage Goodman gas furnace (low nox) and a matching R-32 cased evaporator coil. Every configuration below is an AHRI-matched combination. Choose the configuration for an horizontal installation. The inverter heat pump handles cooling and heats in mild weather. When the outdoor temperature drops below the balance point, the gas furnace takes over. You'll need a thermostat that supports dual fuel, or an outdoor temperature sensor.\u003c\/p\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003ch4\u003eHorizontal Configuration\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump:\u003c\/strong\u003e Goodman GZV6SA4810: 4 ton, R-32, variable-speed inverter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem efficiency:\u003c\/strong\u003e 16.7 SEER2 (AHRI-rated combination)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas furnace:\u003c\/strong\u003e Goodman GDVT801005CX: 100,000 BTU, 80% AFUE, two-stage, variable-speed ECM blower, downflow\/horizontal, 21\" wide, low nox\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaporator coil:\u003c\/strong\u003e Goodman CHPEA4830D3: 4 ton R-32 cased horizontal coil with EEV, 24.5\" wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI reference:\u003c\/strong\u003e 215487322\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eNotes\u003c\/h4\u003e\u003cp\u003e¹ Tested and rated in accordance with ANSI\/AHRI Standard 210\/240\u003cbr\u003e² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes\u003cbr\u003e³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAlways check the S\u0026amp;R plate for electrical data on the unit being installed.\u003c\/li\u003e\n\u003cli\u003eInstaller will need to supply ⅞” to 1⅛” adapters for suction line connections.\u003c\/li\u003e\n\u003cli\u003eUnit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe line set, thermostat and installation materials are not included. Need sizing help? Call 678-535-7176.\u003c\/p\u003e","brand":"Goodman","offers":[{"title":"Horizontal","offer_id":56118445441315,"sku":"GZV6SA4810-GDVT801005CX-CHPEA4830D3","price":7633.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/Goodman_SEER2_R-32_Inverter_Dual_Fuel_System2_b19f2f08-0bd4-4532-9895-f263b5af14bb.webp?v=1795326256"}],"url":"https:\/\/www.acunitsforless.com\/collections\/dual-fuel-systems.oembed","provider":"acunitsforless.com","version":"1.0","type":"link"}