{"title":"Briggs \u0026 Stratton Generators with Transfer Switch","description":"\u003cp\u003eBriggs \u0026amp; Stratton PowerProtect home standby generators packaged with a transfer switch, from 13kW to 26kW, so the generator and switch arrive in one order. Kits range from a 100A 16-circuit switch for essential circuits to 200A service-entrance switches and dual 200A switches for 400A split service. A licensed electrician installs the switch at your main service.\u003c\/p\u003e\u003cp\u003eNot sure which size? Shop by home size: \u003ca href=\"\/collections\/briggs-stratton-generator-essential-circuits\"\u003eessential circuits\u003c\/a\u003e, \u003ca href=\"\/collections\/briggs-stratton-generator-small-homes\"\u003esmall\u003c\/a\u003e, \u003ca href=\"\/collections\/briggs-stratton-generator-mid-size-homes\"\u003emid-size\u003c\/a\u003e, \u003ca href=\"\/collections\/briggs-stratton-generator-large-homes\"\u003elarge homes\u003c\/a\u003e or \u003ca href=\"\/collections\/briggs-stratton-generator-400-amp-service\"\u003e400A split service\u003c\/a\u003e. Already have a switch? See \u003ca href=\"\/collections\/briggs-stratton-generator-only\"\u003egenerator only\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eQuestions? Call 678-535-7176.\u003c\/p\u003e","products":[{"product_id":"briggs-stratton-40742-pp13-13kw-standby-generator","title":"Briggs \u0026 Stratton PowerProtect PP13 - 13\/11.5kW (LP\/NG) Standby Generator w\/ 100 amp 16-circuit Transfer Switch - 40742","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect your home from unexpected power outages with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect™ PP13 13kW Standby Generator with 100 Amp 16-Circuit Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Delivering up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13,000 watts on liquid propane (LP)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e11,500 watts on natural gas (NG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this compact home standby generator is designed to provide dependable automatic backup power while requiring less installation space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePowered by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVanguard® commercial-grade engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and engineered with Briggs \u0026amp; Stratton \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNGMax™ technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect PP13 combines strong natural-gas performance with an exceptionally compact design. Its upright configuration, front exhaust, and corrosion-resistant aluminum enclosure make it especially attractive for homes where available outdoor space is limited.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 Amp 16-circuit transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, creating a practical backup-power solution for homeowners who want to protect selected essential circuits during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e13kW LP \/ 11.5kW NG Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Produces up to 13,000 running watts using liquid propane and 11,500 running watts using natural gas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e100 Amp 16-Circuit Transfer Switch Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides automatic transfer capability for a selected group of essential household circuits.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNGMax™ Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered to provide strong generator performance when operating on natural gas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e37 kVA Motor-Starting Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides additional starting capability for equipment and appliances with higher startup demands.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCompact Installation Footprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed with a footprint stated to be 39% smaller than competing generators in its named class.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e18-Inch Installation Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approved for professional installation as close as 18 inches from a building when installed in accordance with applicable manufacturer requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFront Exhaust Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides additional flexibility when determining generator placement around the home.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® Commercial-Grade Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built around Briggs \u0026amp; Stratton engine technology for reliable standby operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual-Fuel Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to operate using either natural gas or liquid propane.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reinforced aluminum construction features Briggs \u0026amp; Stratton's Dura-Zen™ coating for long-term outdoor durability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e16-Second Weekly Exercise Cycle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A short weekly test cycle helps verify generator readiness while reducing unnecessary noise and fuel consumption.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRemote Generator Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check generator status and receive service-related information using a compatible smartphone, tablet, or computer.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSymphony® Choice Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Optional Symphony Choice Power Management can help prioritize electrical loads according to available generator capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e7-Year Comprehensive Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Warranty coverage includes parts, labor, mileage, and major components according to applicable Briggs \u0026amp; Stratton warranty terms.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEngineered and Assembled in the USA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by more than a century of Briggs \u0026amp; Stratton experience in power equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCompact Standby Power for Homes with Limited Space\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFinding room for a standby generator can be challenging on properties with narrow side yards, smaller lots, landscaping restrictions, or limited equipment space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePowerProtect PP13\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e was designed specifically with installation flexibility in mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts upright configuration provides a footprint stated to be \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e39% smaller than competing generators in its named class\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while its front-exhaust design provides additional flexibility when selecting an installation location.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen installed according to Briggs \u0026amp; Stratton requirements, the generator can be professionally installed as close as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18 inches from a building\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it an attractive option for homes where installation space is at a premium.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton PowerProtect PP13 can operate on either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas (NG) or liquid propane (LP)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenerator output varies depending on the selected fuel:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFuel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRunning Output\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLiquid Propane (LP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13,000 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNatural Gas (NG)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11,500 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator incorporates \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNGMax™ technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, designed to deliver strong performance when the unit is operating on natural gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFuel selection should be based on fuel availability, installation requirements, expected electrical demand, and the home's existing utility infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e37 kVA Motor-Starting Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRunning wattage isn't the only consideration when choosing a standby generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEquipment containing electric motors can require significantly more power during startup than during normal operation. This can include air-conditioning equipment, pumps, refrigerators, and other motor-driven appliances.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect PP13 provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping the generator accommodate the temporary electrical demand associated with starting larger equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual equipment compatibility should always be determined from the electrical requirements of the connected loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e100 Amp 16-Circuit Transfer Switch Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 Amp 16-circuit transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, eliminating the need to purchase the transfer switch separately for compatible installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRather than backing up every circuit in the home, a 16-circuit configuration allows selected circuits to be designated for generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on the home's electrical requirements, these circuits could include equipment such as refrigerators, lighting, internet equipment, selected receptacles, heating equipment, pumps, or other essential household loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe final circuit configuration should be determined by a qualified installer according to generator capacity and household electrical requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSymphony Choice Power Management\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect PP13 is compatible with optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSymphony® Choice Power Management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePower management can help prioritize electrical loads so that a properly designed system can operate important equipment without requiring every connected load to run simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can be particularly useful when designing a standby-power system around larger electrical loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eRemote Generator Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHomeowners can monitor generator status remotely using a compatible smartphone, tablet, or computer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRemote monitoring makes it easier to check the standby system and receive relevant service information without needing to physically inspect the generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor homeowners who travel frequently or maintain a second property, remote monitoring can provide additional visibility into generator status while away from home.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDurable Aluminum Enclosure\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandby generators spend their operating life outdoors, making enclosure construction particularly important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect PP13 uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereinforced, corrosion-resistant aluminum enclosure with Dura-Zen™ coating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to maintain durability and appearance in outdoor environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet 16-Second Weekly Exercise Cycle\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandby generators periodically perform an automatic exercise cycle to help ensure that the system remains ready for an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBriggs \u0026amp; Stratton's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e16-second weekly test mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a short exercise cycle designed to verify generator readiness while helping reduce unnecessary noise and fuel consumption.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePP13\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40742\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHome Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRunning Watts – LP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13,000 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRunning Watts – NG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11,500 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRunning Amperage – LP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e54.2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRunning Amperage – NG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47.9 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level at 7m\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Amp, 16-Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMotor Starting Capability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e37 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Management Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSymphony Choice\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeekly Exercise Cycle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-Year Comprehensive Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWho Is the PowerProtect PP13 Designed For?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton PowerProtect PP13 is particularly well suited for homeowners looking for a compact automatic standby-power solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts combination of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13kW LP \/ 11.5kW NG output, 37 kVA motor-starting capability, compact footprint, dual-fuel operation, and included 100 Amp 16-circuit transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e makes it a strong option for protecting selected essential household loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe appropriate generator size ultimately depends on the home's electrical loads, including equipment startup requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton PowerProtect Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePrepare your home for unexpected utility outages with dependable standby power from Briggs \u0026amp; Stratton.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePowerProtect PP13 13kW Standby Generator – Model 40742\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines a compact installation footprint, Vanguard commercial-grade engine, NGMax technology, dual-fuel capability, remote monitoring, and an included \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100 Amp 16-circuit transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in one residential backup-power package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect standby generators, automatic transfer switches, and generator accessories at AC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for complete home backup-power solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Standby-generator capacity, fuel supply, electrical loads, transfer-switch configuration, clearances, and installation requirements should be evaluated by qualified professionals and installed according to manufacturer instructions and applicable codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655688536355,"sku":"040742","price":5239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/ET17296-Briggs-and-Stratton-PowerProtect-PP13-13-11-5kW-LP-NG-Standby-Generator-w-100-amp-16-circuit-Transfer-Switch-40742-md.webp?v=1790359155"},{"product_id":"briggs-stratton-40743-13kw-standby-generator","title":"Briggs \u0026 Stratton 040743 13kW PowerProtect Generator with 200A SE Transfer Switch \u0026 Symphony Choice Kit","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eKeep your home powered through unexpected utility outages with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 40743 13kW PowerProtect™ Standby Generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Designed for residential backup power, this automatic standby generator delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13kW on liquid propane (LP)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e11kW on natural gas (NG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while providing the motor-starting capability needed for demanding household equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePowered by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVanguard® commercial-grade V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the 40743 combines dependable standby performance with a compact design that provides greater installation flexibility around the home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp SE Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing a properly configured system to automatically respond when utility power is interrupted and transition the home's electrical loads to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e13kW LP \/ 11kW Natural Gas:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel capability allows the generator to operate on either liquid propane or natural gas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to automatically provide backup power when paired with the included compatible automatic transfer switch.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e200 Amp SE Transfer Switch Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports automatic power transfer and whole-home electrical system applications when properly sized and configured.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® Commercial-Grade Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Powered by a Briggs \u0026amp; Stratton Vanguard V-Twin engine designed for reliable standby operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNGMax™ Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered to improve generator performance when operating on natural gas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStrong Motor-Starting Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to handle demanding motor loads, including compatible residential air-conditioning equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSymphony® Choice Power Management:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows a properly configured system to prioritize and manage household electrical loads according to available generator capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCompact Footprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to require less installation space than many conventional standby-generator configurations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFront-Facing Exhaust:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides additional flexibility when determining generator placement.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e18-Inch Installation Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e May be professionally installed as close as 18 inches from a structure when installation conditions and applicable manufacturer requirements are satisfied.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engine lubrication system is designed to support dependable operation and long-term engine protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLCD Control Panel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides convenient access to generator operating information, system status, and fault information.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOptional Remote Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible monitoring capabilities allow generator information to be accessed remotely from supported devices.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutdoor Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to protect the generator and internal components in outdoor residential installations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e60 Hz Single-Phase Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential standby-power applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEngineered and Assembled in the USA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Assembled in the United States using domestic and foreign parts.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Backup Power for Your Home\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 40743 PowerProtect generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to provide automatic backup electricity when normal utility power is unavailable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen an outage occurs, the automatic transfer system detects the loss of utility power and initiates the standby generator. Once generator power is ready, the transfer switch transitions the appropriate household electrical loads to backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the system transfers the loads back to utility power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis automatic operation allows the standby-power system to protect your home even when you're away.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e13kW LP \/ 11kW Natural Gas Performance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 40743 can operate using either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eliquid propane or natural gas\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing homeowners with flexibility when planning their standby-power installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFuel\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eGenerator Output\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLiquid Propane (LP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNatural Gas (NG)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBriggs \u0026amp; Stratton's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNGMax™ technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to improve performance when the generator operates on natural gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe appropriate fuel source should be determined according to local fuel availability, generator demand, fuel-system capacity, installation requirements, and applicable codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e200 Amp Automatic Transfer Switch Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis generator package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp SE Automatic Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switch is an essential part of an automatic standby-generator system because it monitors utility power and manages the transition between utility and generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA properly designed system can be configured around the home's electrical requirements while allowing power management to control larger loads when necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePowering Your Home During an Outage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA properly sized 13kW standby generator can provide backup power for many important household loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on individual equipment requirements and system configuration, these may include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerator and freezer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSump or well pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected kitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResidential air-conditioning equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOther essential household circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual generator capacity depends on the combined running and starting requirements of the connected equipment. Large motors and air conditioners can require substantially more power during startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt for Air-Conditioning Starting Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOne of the most important considerations when selecting a home standby generator is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emotor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir conditioners and other motor-driven equipment can temporarily require considerably more electrical power when starting than they consume during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 40743 is designed with strong motor-starting capability for demanding residential loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir-conditioner compatibility should nevertheless be determined using the actual electrical requirements of the HVAC equipment rather than nominal tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSymphony Choice Power Management\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 40743 is compatible with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSymphony® Choice Power Management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing homeowners to prioritize electrical loads based on available generator capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstead of requiring every large appliance to operate simultaneously, a properly configured power-management system can control when certain electrical loads receive generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can help homeowners design a backup-power system around their most important equipment without automatically requiring a substantially larger generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompact Installation Design\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOutdoor space can be a major consideration when installing a standby generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 40743 features a compact design and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efront-facing exhaust\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing greater flexibility when determining generator placement around the property.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit may be professionally installed as close as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18 inches from a structure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when permitted by Briggs \u0026amp; Stratton installation requirements and applicable local codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenerator installations in areas exposed to hurricanes, flooding, coastal conditions, or severe weather may require additional installation considerations, including an appropriate mounting and anchoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eGenerator Monitoring and Controls\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emulti-line LCD control panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides access to important operating information, including generator status and fault information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatible optional remote-monitoring equipment can provide additional access to generator information from supported smartphones, tablets, and computers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can be particularly useful for homeowners who travel frequently, own vacation properties, or simply want greater visibility into the status of their standby-power system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40743\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Output – LP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRated Output – Natural Gas\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid Propane \/ Natural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVanguard V-Twin Commercial-Grade Engine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Engine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSymphony Choice Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eControl Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-Line LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRemote Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAs close as 18 inches when permitted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCertification \/ Listings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ecUL, UL 2200 and applicable listed approvals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eA Compact Home Standby Power Solution\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 40743 13kW PowerProtect Standby Generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines automatic operation, dual-fuel capability, strong motor-starting performance, a commercial-grade Vanguard engine, power-management compatibility, and an included 200 Amp transfer switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts compact configuration makes it particularly attractive for homeowners who want dependable backup power without dedicating excessive outdoor space to generator equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhether your priority is keeping refrigeration running, maintaining heating and cooling, powering security equipment, or keeping essential household circuits operational, the 40743 can serve as the foundation of a professionally designed residential standby-power system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton Standby Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePrepare your home for unexpected utility outages with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect standby power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 40743 13kW PowerProtect Generator with 200 Amp Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides automatic backup-power capability in a compact residential package designed around dependable performance and installation flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton standby generators, transfer switches, power-management equipment, and generator accessories at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Generator capacity, HVAC compatibility, fuel-system sizing, transfer-switch selection, installation clearance, and electrical configuration should be verified by qualified professionals according to manufacturer instructions and applicable electrical, fuel-gas, and building codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655708721443,"sku":"040743","price":5318.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/ET17296-Briggs-and-Stratton-PowerProtect-PP13-13-11-5kW-LP-NG-Standby-Generator-w-100-amp-16-circuit-Transfer-Switch-40742-md.webp?v=1790359155"},{"product_id":"briggs-stratton-040765-18kw-standby-generator","title":"Briggs \u0026 Stratton 040765 18kW PowerProtect+ Generator with 200A SE Transfer Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect your home from unexpected power outages with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040765 18kW PowerProtect™ Standby Generator with 200 Amp Service Entrance Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Designed as an automatic residential backup-power solution, this package combines an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18kW standby generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service-entrance-rated automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a streamlined whole-home installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120\/240V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 18kW is designed to support the electrical demands of many medium to larger homes. Depending on the home's total load and system configuration, it can provide backup power for heating and cooling equipment, refrigeration, lighting, pumps, household appliances, electronics, and other important circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt the heart of the system is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard® V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, engineered for dependable standby operation. Combined with full-pressure lubrication, automatic controls, dual-fuel capability, and a durable aluminum enclosure, the 040765 is built for homeowners who want reliable backup power without having to manually start and connect a portable generator during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e18kW Standby Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides substantial backup capacity for residential applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e200 Amp SE Transfer Switch Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Service-entrance-rated automatic transfer switch provides automatic transition between utility and generator power.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e120\/240V Single-Phase Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential electrical systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Detects a utility interruption through the transfer system and automatically starts the generator when backup power is required.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® V-Twin Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Briggs \u0026amp; Stratton commercial-grade engine technology designed for dependable standby performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e3,600 RPM Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered for residential standby-generator applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps provide consistent engine lubrication and protection during operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNatural Gas or Liquid Propane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel capability provides flexibility based on the home's available fuel source.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLess Than 5% THD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Produces stable power with low total harmonic distortion for today's household electronics and electrical equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQuiet Residential Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rated at approximately 64 dBA during low-idle operation and 68 dBA during normal operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProgrammable Exercise Cycles:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the generator to periodically exercise itself so the system remains ready for an outage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdvanced Generator Controls:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Controller provides operating information, diagnostics, and system status.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for operation in temperatures ranging from approximately -20°F to 104°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps protect the generator from outdoor environmental conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUL and cUL Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed and tested to applicable safety standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e6-Year Limited Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Backup Power When the Utility Goes Down\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA permanently installed standby generator provides a very different experience from relying on a portable generator during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen normal utility power is interrupted, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e detects the outage and signals the PowerProtect generator to start.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOnce the generator is ready to supply electricity, the transfer switch automatically transitions the home's electrical system from utility power to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the process is reversed and the home is transferred back to utility power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe result is an automatic backup-power system capable of responding even when you're away from home.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e18kW of Residential Standby Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040765 provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18kW of standby power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving homeowners substantial capacity for protecting important household systems during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on the home's electrical demand, a properly configured 18kW standby system may support equipment such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral air-conditioning equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerators and freezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSump and well pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTVs and household electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected receptacles and household circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual capacity depends on the combined running and starting requirements of the connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLarge loads such as central air conditioners, electric water heaters, ranges, dryers, pumps, and other motor-driven equipment should be considered when sizing the generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e200 Amp Service Entrance Transfer Switch Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe included \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service entrance transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a major advantage of this PowerProtect package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switch continuously monitors utility power and automatically manages the transition between utility and generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA 200 Amp service-entrance configuration can be integrated into many residential electrical systems without limiting the installation to a small predetermined group of emergency circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, having a 200 Amp transfer switch does not mean an 18kW generator can simultaneously supply 200 amps of generator power. Generator capacity remains limited by the generator's rated output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor homes with larger electrical demands, appropriate load management may be necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for HVAC and Motor Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHeating and cooling equipment can represent some of the largest electrical loads in a home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectric motors and compressors can also require substantially more electricity during startup than during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton PowerProtect 18kW is designed for residential standby applications where motor-starting capability is an important consideration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen planning to operate central air-conditioning equipment from a standby generator, the HVAC system's actual running and starting requirements should be evaluated during generator sizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClean Power for Modern Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eToday's homes contain significantly more sensitive electronics than homes did just a few decades ago.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComputers, televisions, networking equipment, smart-home devices, appliance control boards, HVAC electronics, and security equipment all depend on stable electrical power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040765 produces \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable power suitable for modern residential electrical loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 18kW is designed to operate using either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving homeowners flexibility when selecting a fuel source.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNatural gas can be convenient for properties already connected to a properly sized utility gas service, while propane can provide an alternative for homes without natural-gas availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFuel selection and supply sizing should be based on generator demand, available infrastructure, expected runtime, local conditions, and applicable installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt for Outdoor Installation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandby generators remain outdoors throughout the year, making enclosure construction an important consideration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040765 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecorrosion-resistant aluminum enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to protect the generator's internal components while providing long-term outdoor durability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate across temperatures ranging from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping provide year-round standby-power capability across a variety of climates.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Residential Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenerator noise can be particularly important when equipment is installed near a home or neighboring property.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 18kW operates at approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Condition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNormal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will vary according to generator placement, surrounding structures, distance, terrain, and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Exercise and System Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA standby generator must remain ready even after months without a utility outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProgrammable exercise cycles allow the PowerProtect system to periodically operate and verify generator readiness.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator's controller also provides system information and diagnostic feedback, helping homeowners and service professionals identify operating conditions and maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e040765\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandby Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard V-Twin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLubrication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTotal Harmonic Distortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eService Entrance Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Low Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Normal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-Resistant Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eListings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the Briggs \u0026amp; Stratton 040765 include a transfer switch?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. This package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service entrance rated automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the equipment needed to automatically transition a compatible residential electrical system between utility and generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan an 18kW generator power an entire house?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt depends on the home's electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn 18kW generator can provide substantial backup capacity for many homes, but a 200 Amp transfer switch does not mean the generator can simultaneously operate every electrical load connected to a 200 Amp electrical service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHomes with large air conditioners, electric heat, electric water heaters, ranges, dryers, pumps, or other high-demand equipment may require load management.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan this generator run central air conditioning?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, yes. The ability to start and operate a particular air-conditioning system depends on the HVAC equipment's running and starting electrical requirements as well as the other loads being powered simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenerator sizing should therefore be based on the actual HVAC equipment specifications rather than tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the generator run on natural gas?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The Briggs \u0026amp; Stratton 040765 is designed to operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fuel system must be properly sized for the generator's requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the generator automatically start during an outage?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. When installed with the included automatic transfer switch, the system is designed to detect a utility outage, start the generator, and automatically transfer the appropriate electrical loads to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the transfer switch returns the electrical system to utility power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the Briggs \u0026amp; Stratton 040765 provide clean power?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output suitable for modern residential equipment and electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow loud is the Briggs \u0026amp; Stratton 18kW generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e64 dBA at low idle and 68 dBA during normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual sound experienced at the property will depend on installation location, distance, nearby structures, and surrounding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton PowerProtect Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePrepare your home for unexpected utility outages with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040765 18kW PowerProtect Standby Generator with 200 Amp SE Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCombining an 18kW standby generator, Vanguard V-Twin engine, dual-fuel capability, low-THD electrical output, automatic controls, durable aluminum enclosure, and included \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service entrance transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this package provides a comprehensive foundation for residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect generators, automatic transfer switches, power-management equipment, and generator accessories at AC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Generator sizing, HVAC compatibility, fuel-system capacity, electrical loads, transfer-switch configuration, and installation requirements should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions and applicable electrical, fuel-gas, and building codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655733494051,"sku":"040765","price":6799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/BAS_ES_PPP18_F-ATS__19378.jpg?v=1790360285"},{"product_id":"briggs-stratton-040795-22kw-standby-generator","title":"Briggs \u0026 Stratton 040795 22kW PowerProtect+ Generator with 200A SE Transfer Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect your home from unexpected utility outages with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040795 22kW PowerProtect™ Standby Generator with 200 Amp Service Entrance Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Designed for residential backup power, this package combines a powerful \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW standby generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service-entrance-rated automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for a comprehensive whole-home backup-power solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120\/240V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 22kW provides substantial capacity for larger homes with demanding electrical loads. Depending on the home's total electrical demand and system configuration, it can provide backup power for central air conditioning, heating equipment, refrigerators and freezers, pumps, lighting, household appliances, electronics, security systems, and other important circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt the heart of the system is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard® V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, engineered for reliable standby operation and long-term durability. Combined with full-pressure lubrication, dual-fuel capability, low-THD electrical output, automatic controls, and a corrosion-resistant aluminum enclosure, the Briggs \u0026amp; Stratton 040795 is built for dependable residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e22kW Standby Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides substantial backup-power capacity for medium to large residential applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e200 Amp SE Transfer Switch Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Service-entrance-rated automatic transfer switch provides automatic transition between utility and generator power.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e120\/240V Single-Phase Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential electrical systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically responds to a utility outage when properly installed with the included transfer switch.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® V-Twin Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Briggs \u0026amp; Stratton commercial-grade engine technology designed for dependable standby-generator operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e3,600 RPM Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered for residential standby-power applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides consistent engine lubrication to help support long-term reliability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNatural Gas or Liquid Propane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel capability provides flexibility based on available fuel infrastructure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLess Than 5% THD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Produces stable electrical output with low total harmonic distortion for modern household equipment and electronics.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQuiet Residential Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 64 dBA during low-idle operation and 68 dBA during normal operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProgrammable Exercise Cycle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the generator to periodically exercise itself to help maintain system readiness.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdvanced Generator Controller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides operating information, system status, and diagnostic feedback.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for operation from approximately -20°F to 104°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides durable protection for outdoor residential installations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUL and cUL Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed and tested to applicable safety standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e6-Year Limited Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Whole-Home Backup Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040795 is designed to eliminate many of the inconveniences associated with manually operating a portable generator during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility power is interrupted, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e detects the outage and initiates the standby-generator sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOnce generator power is available, the transfer switch automatically transitions the home's electrical system from utility power to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen normal utility service returns, the transfer switch moves the electrical system back to utility power and the generator completes its shutdown sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause this process is automatic, the standby system can respond whether you're home, sleeping, traveling, or away from the property.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e22kW of Residential Standby Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWith \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW of standby capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 040795 is designed for homes with more substantial backup-power requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on equipment specifications and total electrical demand, a properly configured 22kW standby system may support loads such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral air-conditioning systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerators and freezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWell and sump pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTVs and household electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected high-demand appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOther essential household circuits\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenerator sizing should always consider both \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erunning watts and starting requirements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir conditioners, pumps, compressors, and other motor-driven equipment can temporarily require considerably more power during startup than during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e200 Amp Service Entrance Transfer Switch Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service-entrance-rated automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for many homes with 200 Amp electrical service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRather than restricting backup power to a small group of predetermined emergency circuits, a service-entrance transfer configuration can provide generator access across the home's electrical system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp rating of the transfer switch should not be confused with generator output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The generator can only supply electrical power up to its rated capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf simultaneous household demand exceeds available generator output, appropriate load management may be required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for Homes with HVAC Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHeating and cooling equipment can represent one of the largest electrical demands in a residential backup-power system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCentral air conditioners, heat pumps, blowers, pumps, and compressors may also have significant startup requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW PowerProtect generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides considerably more standby capacity than smaller residential generator systems, making it an option worth considering for homes where HVAC operation is an important backup-power priority.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual HVAC compatibility should be determined from the equipment's electrical specifications, including running and starting requirements, rather than HVAC tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClean Power for Modern Electronics\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eModern homes rely on sophisticated electronic equipment throughout the property.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComputers, televisions, Wi-Fi equipment, security systems, smart-home devices, HVAC controls, and modern appliances all contain sensitive electronic components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040795 is specified to produce \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern residential equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton PowerProtect 22kW can operate on either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis dual-fuel capability allows homeowners and installers to select the fuel source most appropriate for the property.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNatural gas can provide a convenient option for homes with an appropriately sized utility gas service, while propane provides an alternative for properties without natural-gas availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator's fuel supply must be properly sized according to generator demand, fuel type, piping distance, local conditions, and applicable installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt for Outdoor Installation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA standby generator remains exposed to outdoor conditions throughout the year.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040795 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecorrosion-resistant aluminum enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to protect the generator's internal components and provide long-term outdoor durability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system is designed for operation across temperatures ranging from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing year-round standby capability across a wide range of climates.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Residential Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSound is an important consideration when installing a standby generator near a home or neighboring property.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Condition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNormal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound can vary according to installation location, distance, surrounding structures, terrain, and environmental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Exercise and Generator Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandby generators may go weeks or months without being needed for an actual outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprogrammable exercise cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows the PowerProtect generator to periodically operate and verify system readiness.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe advanced generator controller also provides operating information and diagnostic feedback, helping homeowners and service technicians monitor system condition and identify potential maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e040795\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandby Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard V-Twin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLubrication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTotal Harmonic Distortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eService Entrance Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Low Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Normal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-Resistant Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eListings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the Briggs \u0026amp; Stratton 040795 include a transfer switch?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The Briggs \u0026amp; Stratton 040795 package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp service-entrance-rated automatic transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switch monitors utility power and automatically manages the transition between utility and generator power during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan a 22kW generator power an entire house?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA 22kW standby generator provides substantial capacity for many residential applications, but actual whole-home capability depends on the home's electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHomes with multiple HVAC systems, electric heat, electric water heaters, ranges, dryers, pool equipment, pumps, EV chargers, or other large loads may exceed 22kW if several loads operate simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLoad management may therefore be appropriate for some installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat can a 22kW standby generator run?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on total electrical demand and equipment startup requirements, a properly configured 22kW system may support central air conditioning, refrigeration, lighting, pumps, heating equipment, kitchen appliances, electronics, security systems, and numerous other household circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation is the best way to determine which equipment can operate simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the Briggs \u0026amp; Stratton 040795 run central air conditioning?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, yes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhether the generator can start and operate a particular central air-conditioning system depends on the HVAC equipment's running current, starting requirements, other connected loads, and overall system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHVAC compatibility should therefore be evaluated using the actual equipment specifications rather than tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the advantage of the 200 Amp service entrance transfer switch?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe included \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e200 Amp SE transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows the standby-power system to integrate with many residential 200 Amp electrical services instead of restricting generator power to a small number of predetermined circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGenerator capacity still determines how much equipment can operate simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the generator automatically start during an outage?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. When properly installed with the included automatic transfer switch, the system is designed to detect utility failure, start the generator, and automatically transition the electrical system to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility power returns, the system automatically transfers back to the utility source.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the Briggs \u0026amp; Stratton 040795 run on natural gas?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. The generator is designed to operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe selected fuel system must be appropriately sized for generator demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes this generator provide clean power for electronics?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications state that the generator produces \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern residential electronics and appliances.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow loud is the Briggs \u0026amp; Stratton 22kW generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e64 dBA in low-idle operation and 68 dBA during normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual sound levels experienced at the property will depend on generator placement and surrounding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton 22kW Standby Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePrepare your home for unexpected utility outages with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040795 22kW PowerProtect Standby Generator with 200 Amp SE Transfer Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCombining \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW of residential standby capacity, a Vanguard V-Twin engine, dual-fuel operation, low-THD electrical output, automatic controls, durable aluminum construction, and an included 200 Amp service entrance transfer switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this package provides a comprehensive foundation for residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect standby generators, automatic transfer switches, power-management equipment, and generator accessories at AC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Generator sizing, HVAC compatibility, fuel-system capacity, connected electrical loads, transfer-switch configuration, and installation requirements should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions and applicable electrical, fuel-gas, and building codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655752892707,"sku":"040795","price":7189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/BAS_ES_PPP18_F-ATS__19378_33eb62be-8cb5-4470-9493-79d80f0bac88.jpg?v=1790360584"},{"product_id":"briggs-stratton-040794-22kw-generator-dual-200a-transfer-switch","title":"Briggs \u0026 Stratton 040794 22kW PowerProtect+ Generator with Dual 200A SE Transfer Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel Number: 040794\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect homes with multiple electrical panels using the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040794 22kW PowerProtect™ Standby Generator with Dual 200 Amp Service Entrance Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This residential standby-power package combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW automatic generator with two 200 Amp service-entrance-rated transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing greater installation flexibility for properties with multiple electrical panels or more complex electrical-service configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120\/240V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 22kW provides substantial backup capacity for residential applications. Depending on total electrical demand and system configuration, it can support central HVAC equipment, refrigeration, pumps, lighting, appliances, electronics, security systems, and other important household loads during a utility outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt the heart of the system is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard® V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, engineered for reliable standby operation. Combined with dual-fuel capability, full-pressure lubrication, low-THD electrical output, automatic controls, and a corrosion-resistant aluminum enclosure, the 040794 provides a comprehensive foundation for residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e22kW Standby Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides substantial backup capacity for medium to large residential applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual 200 Amp SE Transfer Switches Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two service-entrance-rated automatic transfer switches provide additional flexibility for homes with multiple electrical panels or compatible multi-panel configurations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e120\/240V Single-Phase Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential electrical applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The transfer system monitors utility power and automatically initiates generator operation when an outage occurs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® V-Twin Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Briggs \u0026amp; Stratton commercial-grade engine technology designed for dependable standby operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e3,600 RPM Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered for residential standby-generator applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps provide consistent engine lubrication and long-term engine protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNatural Gas or Liquid Propane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel operation provides flexibility according to the property's available fuel source.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLess Than 5% THD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides stable electrical output with low total harmonic distortion for modern household equipment and electronics.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQuiet Residential Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 64 dBA during low-idle operation and 68 dBA during normal operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProgrammable Exercise Cycle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the generator to periodically operate to help maintain system readiness.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdvanced Generator Controller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides operating information, system status, and diagnostic feedback.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for operation from approximately -20°F to 104°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for long-term outdoor installation and protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-Wind-Rated Enclosure Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built for applications requiring additional consideration for severe weather conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUL and cUL Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed and tested to applicable safety standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e6-Year Limited Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBackup Power for Homes with Multiple Electrical Panels\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe major difference between the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040794\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a conventional single-transfer-switch package is the inclusion of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo 200 Amp service entrance transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSome larger homes and properties have multiple electrical panels or electrical-service configurations that require more than one transfer switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch configuration provides installers with additional flexibility when integrating the standby generator into these electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can make the 040794 particularly useful for properties with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMultiple main electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpanded residential electrical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge homes with distributed electrical loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible multi-panel service configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperties where a single transfer switch does not meet the installation requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe appropriate configuration should always be determined from the property's actual electrical-service design.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eImportant: Dual 200 Amp Transfer Switches Do Not Mean 400 Amps of Generator Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two transfer switches determine \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehow electrical loads can be transferred between utility and generator power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. They do not increase the electrical output of the generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040794 remains a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor example, a property may have two electrical panels connected through the appropriate transfer configuration, but the combined electrical demand placed on the generator must remain within the generator's available capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf potential demand exceeds generator capacity, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eload management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may be necessary to prevent excessive loads from operating simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Backup Power During an Outage\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility power is operating normally, the home's electrical system receives electricity from the utility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf an outage occurs, the automatic transfer system detects the loss of utility power and initiates generator startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOnce the PowerProtect generator is ready to supply electricity, the transfer system transitions the appropriate electrical loads from utility power to generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the transfer system moves the electrical loads back to utility power and the generator completes its shutdown sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis automatic process allows the standby-power system to respond whether you're home or away.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e22kW of Residential Standby Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWith \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW of standby capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the Briggs \u0026amp; Stratton 040794 is designed for homes with substantial backup-power requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on individual equipment requirements and total electrical demand, a properly configured system may support equipment such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral air-conditioning systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerators and freezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWell and sump pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTVs and household electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected high-demand appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEssential circuits across multiple electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe amount of equipment that can operate simultaneously depends on the combined running and starting requirements of the connected loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for HVAC and Motor Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCentral HVAC equipment can represent one of the largest electrical demands in a home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir conditioners, heat pumps, compressors, pumps, and other motor-driven equipment may require significantly more power during startup than during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 22kW provides substantial residential standby capacity, making it suitable for consideration when maintaining heating and cooling is an important backup-power objective.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual HVAC compatibility should be determined using the equipment's electrical specifications and starting requirements rather than tonnage alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClean Power for Modern Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eModern residential electrical systems contain sensitive electronic components throughout the home.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComputers, televisions, Wi-Fi equipment, security systems, smart-home devices, HVAC control boards, and modern appliances all benefit from stable electrical power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040794 is specified to produce \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern household equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton PowerProtect 22kW is designed to operate on either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNatural gas may be convenient for properties already connected to an appropriately sized utility gas service, while propane provides another option for properties without natural-gas availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fuel supply must be properly sized according to generator demand, fuel type, piping distance, pressure, local conditions, and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDurable Outdoor Construction\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause standby generators remain outdoors throughout the year, enclosure construction is an important consideration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040794 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecorrosion-resistant aluminum enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to protect the generator's internal components from outdoor conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications also identify a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-wind-rated enclosure design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making the system suitable for consideration in areas where severe-weather installation requirements are important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate across temperatures ranging from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Residential Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list the following approximate operating sound levels:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Condition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNormal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will vary depending on generator placement, distance, nearby structures, terrain, and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAutomatic Exercise and System Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA standby generator may remain unused for extended periods between utility outages.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect system includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprogrammable exercise cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the generator to periodically operate and help verify system readiness.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts advanced controller also provides operating information, diagnostic feedback, and system status information for homeowners and service professionals.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e040794\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandby Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard V-Twin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLubrication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTotal Harmonic Distortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switches Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes – Two\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp Each\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eService Entrance Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Low Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Normal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e68 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-Resistant Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eListings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWhy does the Briggs \u0026amp; Stratton 040794 include two 200 Amp transfer switches?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch configuration is intended to provide greater installation flexibility for properties with multiple electrical panels or compatible electrical-service configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe exact use of each transfer switch depends on the property's electrical design and should be determined by a qualified installer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDo two 200 Amp transfer switches make this a 400 Amp generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer-switch ratings should not be added together to determine generator output. The generator remains rated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, regardless of the number of transfer switches installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switches manage how compatible electrical systems transition between utility and generator power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the 22kW generator power both electrical panels?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch configuration can provide generator access to loads across compatible multiple-panel installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, the combined load placed on the generator must remain within its available capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf the potential demand across both panels exceeds generator output, appropriate load management may be required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the Briggs \u0026amp; Stratton 040794 power an entire house?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, depending on the home's electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA 22kW generator provides substantial residential backup capacity, but homes with multiple HVAC systems, electric heat, water heaters, ranges, dryers, pool equipment, EV chargers, or other large electrical loads may exceed generator capacity if too many loads operate simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation should be performed to determine the appropriate system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan this generator operate central air conditioning?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, yes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatibility depends on the HVAC equipment's running requirements, motor-starting demand, other simultaneous electrical loads, and overall system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHVAC compatibility should be determined from the actual electrical specifications of the equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes the generator automatically start during an outage?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYes. When properly installed with the automatic transfer system, the generator is designed to automatically respond to a utility outage and provide backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen utility service returns, the system transfers the electrical loads back to utility power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat fuel does the Briggs \u0026amp; Stratton 040794 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing flexibility according to available fuel infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes it provide clean power for electronics?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern residential equipment and electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow loud is the 22kW PowerProtect generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e64 dBA during low-idle operation and 68 dBA during normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual sound experienced at the property will depend on installation location and surrounding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton PowerProtect Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor homes with multiple electrical panels or more complex electrical-service configurations, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040794 22kW PowerProtect Standby Generator with Dual 200 Amp SE Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a flexible foundation for automatic residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22kW of standby capacity, dual 200 Amp service entrance transfer switches, Vanguard V-Twin engine technology, natural gas or propane operation, low-THD electrical output, automatic controls, and durable aluminum construction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton PowerProtect standby generators, automatic transfer switches, power-management equipment, and generator accessories at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual transfer switches do not increase generator output. Generator sizing, connected loads, HVAC compatibility, fuel-system capacity, transfer-switch configuration, and installation requirements should be evaluated by qualified professionals according to Briggs \u0026amp; Stratton instructions and applicable electrical, fuel-gas, and building codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655852835107,"sku":"040794","price":8494.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/BAS_ES_PPP18_F-ATS__19378_33eb62be-8cb5-4470-9493-79d80f0bac88.jpg?v=1790360584"},{"product_id":"briggs-stratton-040814-26kw-generator-dual-200a-transfer-switch","title":"Briggs \u0026 Stratton 040814 26kW PowerProtect+ Generator with Dual 200A SE Transfer Switch","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel Number: 040814\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtect larger homes and properties with complex electrical systems using the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040814 26kW PowerProtect™ Standby Generator with Dual 200 Amp Service Entrance Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This residential backup-power package combines a high-capacity \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW standby generator with two 200 Amp service-entrance-rated automatic transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing greater installation flexibility for homes with multiple electrical panels or expanded electrical-service requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDelivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120\/240V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the PowerProtect 26kW is designed for demanding residential applications where maintaining HVAC, refrigeration, pumps, lighting, appliances, electronics, security systems, and other important loads during an outage is a priority.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system is powered by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard® V-Twin engine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and offers up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65.5 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping accommodate demanding motor loads such as air-conditioning equipment and pumps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWith dual-fuel operation, low total harmonic distortion, an advanced \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGC-1032 controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, quiet operation, and a corrosion-resistant aluminum enclosure rated for winds up to 186 mph, the Briggs \u0026amp; Stratton 040814 is designed for dependable automatic backup power in demanding residential applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e26kW Standby Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-capacity residential standby power designed for larger homes and demanding electrical loads.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual 200 Amp SE Transfer Switches Included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two service-entrance-rated automatic transfer switches provide greater flexibility for compatible multi-panel electrical systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e120\/240V Single-Phase Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for standard residential electrical applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Standby Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically responds to utility outages when properly installed with the included transfer-switch system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eVanguard® V-Twin Engine:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Briggs \u0026amp; Stratton engine technology engineered for dependable standby operation and long-term durability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e65.5 kVA Motor-Starting Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides substantial starting capability for demanding motor-driven equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNatural Gas or Liquid Propane:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-fuel operation allows the system to be configured around the property's available fuel source.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLess Than 5% THD:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Produces stable electrical output with low total harmonic distortion for modern electronics and household equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectronic Governor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides ±1% frequency regulation for stable generator performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eGC-1032 Controller:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Advanced generator controller provides system information, operating status, and diagnostic capabilities.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProgrammable Exercise Cycle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Exercise duration can be configured from approximately 16 seconds up to 20 minutes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQuiet Residential Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 63 dBA during low-idle operation and 65 dBA during normal operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFull-Pressure Lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps provide consistent engine lubrication and protection during extended operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCorrosion-Resistant Aluminum Enclosure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for long-term outdoor installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUp to 186 MPH Wind Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Enclosure is designed for demanding installation environments and severe-weather applications.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Operating Temperature Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for operation from approximately -20°F to 104°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUL and cUL Listed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed and tested to applicable safety standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e7-Year Limited Warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Backed by Briggs \u0026amp; Stratton limited warranty coverage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eHigh-Capacity Backup Power for Larger Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040814 PowerProtect 26kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for homeowners who require more backup capacity than smaller residential standby generators can provide.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on total electrical demand and system configuration, a properly designed 26kW standby system may support equipment such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCentral air-conditioning systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeating equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRefrigerators and freezers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWell and sump pumps\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternet and networking equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSecurity systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGarage-door equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchen appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTVs and household electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelected high-demand appliances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEssential loads distributed across multiple electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual generator capacity depends on the combined running and starting requirements of all equipment operating at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDual 200 Amp Service Entrance Transfer Switches\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOne of the distinguishing features of the Briggs \u0026amp; Stratton 040814 package is the inclusion of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo 200 Amp service entrance transfer switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSome larger properties use multiple electrical panels or more complex service configurations. A single automatic transfer switch may not provide the installation flexibility required for these systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch package can provide an installer with additional options for integrating generator backup power across compatible multi-panel electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration may be appropriate for properties with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMultiple main electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge homes with distributed electrical loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExpanded residential electrical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible detached-building configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperties where the electrical design requires more than one automatic transfer switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe appropriate configuration depends on the property's electrical architecture and should be determined by a qualified electrical professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDual 200 Amp Transfer Switches Do Not Equal 400 Amps of Generator Power\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two transfer switches expand the ways the generator can be integrated into a property's electrical system. They \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edo not double the generator's electrical output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 remains a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW standby generator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEven when two 200 Amp transfer switches provide access to loads across multiple panels, the combined electrical demand placed on the generator must remain within its available output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf potential demand exceeds generator capacity, an appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eload-management strategy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may be necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e65.5 kVA Motor-Starting Capability\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRunning wattage is only part of residential generator sizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEquipment containing motors and compressors can require significantly more electrical power for a short period during startup. Central air conditioners, heat pumps, well pumps, pool equipment, and other motor-driven loads are common examples.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 provides up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65.5 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving the generator additional capacity for starting demanding residential equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis can be particularly valuable for homeowners who consider maintaining HVAC operation an important part of their outage plan.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual equipment compatibility should always be determined using the electrical specifications of the connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for Residential HVAC Loads\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHeating and cooling can represent a significant portion of a home's electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 26kW provides substantial standby capacity and motor-starting capability for residential applications where maintaining HVAC operation is important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, generator sizing should not be based solely on the nominal tonnage of an air conditioner or heat pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation should consider:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHVAC running amperage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompressor starting requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdditional household loads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNumber of HVAC systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment operating simultaneously\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAvailable load-management equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis provides a more accurate picture of whether the generator can operate the desired equipment during an outage.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClean, Stable Power for Modern Homes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eToday's homes contain sensitive electronics throughout their electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComputers, televisions, networking equipment, security systems, smart-home devices, HVAC control boards, and modern appliances all rely on stable electrical power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 is specified to produce \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator also incorporates an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic governor with ±1% frequency regulation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping maintain consistent electrical performance as loads change.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eNatural Gas or Liquid Propane Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe PowerProtect 26kW is designed to operate using either \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis provides flexibility when planning the installation around the property's available fuel infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNatural gas can provide a convenient option for homes with an appropriately sized utility gas service, while propane provides an alternative for properties without natural-gas availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe fuel system must be appropriately sized according to generator demand, fuel type, piping distance, pressure, local conditions, and applicable installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdvanced GC-1032 Generator Controller\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGC-1032 controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides centralized monitoring and control of generator operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe controller provides operating information, system status, and diagnostic feedback that can assist homeowners and service professionals with monitoring generator performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProgrammable exercise functionality also allows the generator to periodically operate so the system can remain prepared between actual utility outages.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eExercise duration can be configured from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e16 seconds up to 20 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, depending on the selected system settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eQuiet Residential Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDespite its high residential output, the PowerProtect 26kW is designed with residential sound levels in mind.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Condition\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNormal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will vary according to generator placement, distance, nearby structures, terrain, and surrounding environmental conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBuilt for Demanding Outdoor Conditions\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA standby generator remains outdoors throughout the year, making enclosure durability especially important.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Briggs \u0026amp; Stratton 040814 features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecorrosion-resistant aluminum enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to protect the generator's internal components from outdoor conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications identify the enclosure as having a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewind rating up to 186 mph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing additional consideration for installations in areas exposed to severe weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is also designed for operation across temperatures ranging from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFinal generator placement, mounting, anchoring, and installation requirements should always follow Briggs \u0026amp; Stratton instructions and applicable local codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerProtect\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e040814\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eGenerator Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic Home Standby Generator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStandby Output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas \/ Liquid Propane Vapor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBriggs \u0026amp; Stratton Vanguard V-Twin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEngine Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3,600 RPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLubrication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMotor-Starting Capability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 65.5 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTotal Harmonic Distortion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess Than 5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency Regulation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eController\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGC-1032\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switches Included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes – Two\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Amp Each\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransfer Switch Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eService Entrance Rated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Low Idle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e63 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSound Level – Normal Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrosion-Resistant Aluminum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWind Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 186 mph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°F to 104°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eListings\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL \/ cUL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7-Year Limited Warranty\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eWhen Do You Need Dual 200 Amp Transfer Switches?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA dual-transfer-switch configuration may be appropriate when the property's electrical design requires more than one automatic transfer point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotential applications include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHomes with multiple main electrical panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLarge residences with distributed electrical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEstates with expanded electrical infrastructure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible detached garages or accessory structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProperties with high electrical demand distributed across multiple panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDual transfer switches should not automatically be assumed necessary simply because a property has subpanels. The appropriate transfer configuration depends on how the electrical service and panels are designed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWhy does the Briggs \u0026amp; Stratton 040814 include dual 200 Amp transfer switches?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two 200 Amp service entrance transfer switches provide additional flexibility for properties with compatible multiple-panel electrical configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThey allow an installer to integrate automatic backup power across electrical systems where a single transfer switch may not meet the property's requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDo two 200 Amp transfer switches provide 400 amps of generator power?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer switches are rated according to the electrical service they are designed to transfer. They do not increase generator output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator itself remains rated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the combined loads operating from both panels must remain within available generator capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the 26kW generator power both electrical panels?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe dual-transfer-switch system can provide generator access to loads across compatible multiple-panel installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, whether all connected equipment can operate simultaneously depends on total electrical demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLoad management may be required when the combined demand exceeds generator capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan a 26kW generator power an entire large home?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, but this depends on the home's electrical loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA 26kW generator provides substantial residential backup capacity, but large homes may contain multiple HVAC systems, electric heating, electric water heaters, ranges, dryers, pool equipment, pumps, EV chargers, and other high-demand equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA professional load calculation should be used to determine the appropriate generator and load-management configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan the Briggs \u0026amp; Stratton 040814 run central air conditioning?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePotentially, yes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator provides up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e65.5 kVA of motor-starting capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which can be beneficial when starting motor-driven equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual HVAC compatibility depends on the air-conditioning equipment's running requirements, starting demand, other simultaneous loads, and overall system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat fuel does the Briggs \u0026amp; Stratton 040814 use?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe generator is designed to operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enatural gas or liquid propane vapor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe selected fuel system must be properly sized to supply the generator under the expected operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes this generator provide clean power?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5% total harmonic distortion (THD)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e along with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e±1% frequency regulation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing stable electrical output for modern household equipment and electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHow loud is the Briggs \u0026amp; Stratton 26kW generator?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications list approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e63 dBA during low-idle operation and 65 dBA during normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual perceived sound will depend on generator placement and surrounding conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the wind rating?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe supplied specifications identify the generator enclosure as having a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewind rating up to 186 mph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstallation requirements, including mounting and anchoring, should still be determined according to Briggs \u0026amp; Stratton instructions and applicable local building requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eShop Briggs \u0026amp; Stratton 26kW Standby Generators at AC Units For Less\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor larger homes and properties with multiple electrical panels, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton 040814 26kW PowerProtect Standby Generator with Dual 200 Amp SE Transfer Switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a high-capacity foundation for automatic residential backup power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e26kW of standby capacity, dual 200 Amp service entrance transfer switches, up to 65.5 kVA motor-starting capability, Vanguard V-Twin engine technology, natural gas or propane operation, low-THD electrical output, GC-1032 controls, and durable aluminum construction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShop \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBriggs \u0026amp; Stratton PowerProtect standby generators, automatic transfer switches, power-management equipment, and generator accessories at AC Units For Less\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eImportant:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual transfer switches expand transfer capability but do not increase the generator's 26kW output. Generator sizing, HVAC compatibility, fuel-system capacity, electrical loads, transfer-switch configuration, mounting, and installation requirements should be evaluated by qualified professionals according to manufacturer instructions and applicable codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":55655879246115,"sku":"040814","price":9187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1171\/5363\/files\/BAS_ES_PPP18_F-ATS__19378_33eb62be-8cb5-4470-9493-79d80f0bac88.jpg?v=1790360584"}],"url":"https:\/\/www.acunitsforless.com\/collections\/briggs-stratton-generator-with-transfer-switch.oembed","provider":"acunitsforless.com","version":"1.0","type":"link"}